Guangzhou Zunhui Information Technology Co., Ltd
Home>Products>TURNER TD-4100 Online Oil Detector in Water from the United States
TURNER TD-4100 Online Oil Detector in Water from the United States
Product model: TD-4100 Brand: TURNER USA Price: negotiable Power input: 4-20mA Measurement range: 1ppb-1000ppm Processing customization: No Location:
Product details
Product Introduction

TURNER Instruments is a global leader in portable oil in water applications, measuring and monitoring hydrocarbons in water through laboratory and online continuous monitoring processes.

Our expert monitors the concentration of oil (hydrocarbons) in water ranging from micrograms per liter (concentration) to milligrams per liter (parts per million). The detection limit for crude oil, gasoline, diesel, aviation kerosene, and fuel oil has been proven to be 10 parts per billion distilled water. As an example, many of our installed systems regularly monitor the concentration of gasoline and diesel in drinking water at 30% in river water. We often customize systems to meet highly specialized monitoring projects, especially in the offshore oil production market.

main features
Non contact, uncontaminated circulation pool
TD-4100 does not come with a glass circulation pool.
Hydrocarbons passing through an open chamber
The water flow entering the room is detected, and the water
The flow will not come into contact and contaminate the optical window
Mouth. Exclusive and proprietary air curtain system
Suitable for use in humid environments or in hot environments
When in water, keep the optical window free
Clear fog state.
Minor maintenance and upkeep
No need to replace test tubes, pumps, or valves
The door. Daily maintenance and upkeep include:
Replace the lights twice a year.
CheckPOINT TM is a reliable standard
Enable you to easily carry out
System check. Must match the sample
Proper maintenance should be carried out on this line to
Perform fault free operation.
Direct continuous monitoring
TD-4100 is capable of handling water in motion
Continuous monitoring of the flow. Monitoring water
When it comes to hydrocarbons, it is not necessary
Any chemical drug, no prior treatment required
Reason, without any mechanical operation or
Mix the samples.
accurate
TD-4100 direct measurement of fluorescence in water
The accuracy of hydrocarbons is consistent
Laboratory methods with standardized management
Maintain relevance.
High sensitivity and selectivity
sensitive
TD-4100 can detect benzene derivatives, gasoline, diesel, jet fuel, crude oil, aromatic solvents, and refined petroleum products, with a detection range ranging from as low as ppb (μ g/L) to as high as ppm (mg/L). For example, TD-4100 XD can detect diesel fuel in 1 ppb of water without interference from compounds.
selectiveness
TD-4100 only measures fluorescent hydrocarbons in water. Fluorescence reaction occurs when a molecule absorbs a specified wavelength of light energy and emits longer wavelength light energy. This means that TD-4100 is minimally or completely unaffected by interference from suspended solids.
Effective monitoring in wastewater
Turbid water or sewage can affect the absorption of ultraviolet, infrared, visible light, or light scattering instruments, while fluorescence technology enables the TD-4000 to resist interference from turbid water or sewage. Most substances absorb light, but they absorb very little fluorescence. If a substance in the monitored hydrocarbons does not emit fluorescence at a specified wavelength, it will not constitute interference.
user-friendly
The design of TD-4000 aims to provide comfortable operation. Simple onboard software can control alarms, 4-20mA output, diagnosis, and calibration. Turner Designs is a recognized expert in monitoring oil in water using hydrocarbon instruments.
Technical Parameter
The detection range is 1ppb ->1000ppm, depending on the water source and target hydrocarbons.
Size 44.0 'x 43.1' x 10.8 '(111.8cm x 109.4cm x 27.5cm)
Weight 64 pounds (29 kilograms)
The local display is, PPM,PPB, Or the original signal
Control internal touchpad, password protected
Power requirements: 110-240 volts AC, 50/60 hertz, 24 volts DC optional
Pipeline requirements: Water supply pipe: 1/2 'MNPT (standard) or 1/2' return pipe: 2 'free drainage pipe
Sample pressure inlet: 0.5-2 gallons per minute (2-8 liters per minute), 5-20 pounds per square inch (34-138kpag), sample pump optional
Return: Atmospheric pressure sample return pump optional
Sample temperature<140 ° F (60 ° C) w/PVC pipe
190 ° F (95 ° C) (* * * large) w/optional stainless steel pipe
When the required air supply pressure for general use is 10-20 pounds per square inch, it is 15 standard cubic feet per hour
The operating temperature around is 32 ° -120 ° F (0-49 °), and a heater or vortex cooler is optional
Non contact flow pool with air curtain characteristics
Working principle: UV fluorescence
Stability+/-10% for over 6 months
Response time<10 seconds, continuous real-time response
Calibration blank/standard addition or related to standard methods
No reagents available
Alarm 2: Warning/High Alarm, Internal Fault Connected to High Alarm
Alarm contact A/C, dry contact optional
Output 4-20mA
Communication protocol options: Hart,ModBus
Diagnosis self diagnosis, internal faults connected to relays and LCD screens
Software with secure password protection, attachments can be locked
Electronic control cabinet made of glass fiber reinforced plastic
IP rating IP66, American Electrical Manufacturers Association standard 4X
Maintenance and repair of lights (twice a year); Daily cleaning of pipelines
Certificate International Maritime Organization Marine Environment Protection Committee 107 (49), 60 (33)
Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!