Introduction to Digital Fluorescence Oscilloscope:
Digital fluorescence oscilloscope with 100M bandwidth and four channels, 1M storage depth, and a sampling rate of up to 1GS/s.
Detailed information of digital fluorescence oscilloscope:
Multi functional mixed signal design and debugging tool for digital fluorescence oscilloscope
The digital fluorescence technology on MSO2000 and DPO2000 series digital fluorescence oscilloscopes achieves a waveform capture rate of 5000 waveforms per second and real-time brightness level.
Professional design of digital fluorescence oscilloscope to make your work easier as a Wave Inspector? Navigation and search Imagine that without search engines such as Google and Yahoo, without web browser functions such as Favorites, without links, without Internet service providers such as AOL and MSN, you will not be able to effectively use the Internet! So, you will now know how most modern oscilloscope users feel when attempting to use the long recording length of a digital oscilloscope. Record length is one of the key indicators of an oscilloscope, which refers to the number of sample points that can be digitized and stored in one acquisition. The longer the recording length, the longer the time window that can be captured with high resolution (high sampling rate).
The world's first digital oscilloscope could only capture and store 500 samples, making it difficult to collect all relevant information for the investigated events. Over the years, oscilloscope manufacturers have offered increasingly longer recording lengths to meet the demand for long capture windows with high resolution. High resolution has either become the standard configuration for most mid-range oscilloscopes, or users can choose to upgrade to recording lengths of a few megabits.
Main performance indicators of digital fluorescence oscilloscope:
100MHz bandwidth type
● 4 analog channels
16 digital channels (MSO2000 series)
All channels have an upsampling rate of up to 1GS/s
Record the length of 1M points on all channels
● Maximum waveform capture rate of 5000wfm/s
● Advanced trigger kit
Digital fluorescence oscilloscope serial bus triggering and decoding:
● I2C, SPI, CAN, LIN, Serial triggering, decoding, and analysis options with RS-232/422/485/UART
Easy to use functions of digital fluorescence oscilloscope
Wave Inspector navigation and search provide unprecedented waveform analysis efficiency
Filtering Vu variable low-pass filter can filter out unwanted signal noise while still capturing high-frequency events
● 180mm widescreen TFT-LCD color display
USB 2.0 port on the front panel for quick and easy storage of data
● USB 2.0 device port on the back panel, use USB TMC to directly control the oscilloscope through a PC, or print directly to any PictBridge compatible printer
Plug and play PC connection and analysis software solution
TekVPI probe interface, supports active probes, differential probes, and current probes, automatically calibrates and determines measurement units
● Small size, light weight, only 5.3 inches (134mm) deep, weighing only 7 pounds 14 ounces (3.6 kilograms)
Mixed Signal Design and Analysis (MSO2000 Series)
● Can provide up to 4 analog and 16 digital channels related to time
● Parallel bus triggering and analysis
● Multi channel establishment time and holding time trigger
Next generation digital waveform display
Application scope of digital fluorescence oscilloscope:
Embedded design and debugging
● Mixed signal design and debugging
● Power measurement
● Automotive Electronics
Education and Training
● Video design and debugging
Technical specifications of digital fluorescence oscilloscope:
Vertical System - Analog Channel
Vertical System Simulation Channel MSO2012
DPO2012
MSO2014
DPO2014
MSO2024
DPO2024 Input Channels 2 4 4
Analog bandwidth * 1 (-3 dB) 100 MHz 100 MHz 200 MHz
Calculated rise time 3.5 ns 3.5 ns 2.1 ns
Hardware bandwidth limit of 20 MHz
Input coupling AC, DC, GND
Input impedance 1 M Ω± 2%, 11.5 pF ± 2 pF
Input sensitivity range 2 mV/div -5 V/div
Vertical resolution 8-bit
Maximum input voltage 300 VRMS, peak value ≤ 450 V
DC gain accuracy (bias set to 0V) 10 mV/div -5 V/div is ± 3%, 2 mV/div -5 mV/div is ± 4%
Bias range
2 mV/div - 200 mV/div ± 1 V
>200 mV/div - 5 V/div ± 25 V
Channel to channel isolation
(Any two channels on equal vertical scale) ≥ 100:1 when ≤ 100 MHz ≤ 100:1 when ≤ 200 MHz ≥ 100:1
*The bandwidth at 12 mV/div is 20 MHz for all models
Vertical System - Digital Channel
MSO2012
MSO2014
MSO2024 input channel 16 digital channels (D15-D0)
Threshold: One threshold for every 8 channel groups
Threshold selection TTL, CMOS, ECL, PECL, User defined
User defined threshold range ± 20 V
Maximum input voltage ± 40 V
Threshold accuracy ± (100 mV+3% threshold setting)
Maximum input dynamic range of 80 Vpk pk (depending on threshold setting)
Minimum voltage swing of 500 mVpk pk
Input impedance 101 k Ω
Probe load 8 pF
Vertical resolution of 1 bit
Horizontal System - Analog Channel
MSO2012
DPO2012 MSO2014
DPO2014 MSO2024
DPO2024
Maximum sampling rate (all channels) 1 GS/s
Minimum peak detection pulse width 7.0 ns 3.5 ns
Maximum record length (all channels) 1 M points
Maximum duration captured at the highest sampling rate (all channels) 1 ms
Time base range 4 ns -100 s 2 ns -100 s
Time base delay time range -10 div -5000 s
Channel to channel offset correction range ± 100 ns
Time base accuracy ± 25 ppm
Horizontal System - Digital Channel
MSO2012 MSO2014 MSO2024
Maximum sampling rate (when using any channel D7-D0) 1 GS/s (1 ns resolution)
Maximum sampling rate (when using any of channels D15-D8) 500 MS/s (2 ns resolution)
Maximum record length 1 M points
Minimum detectable pulse width of 5 ns
Channel to channel offset correction 2 ns typical value
All models include:
Each analog channel has one P2221200 MHz, 1x/10x passive probe, user manual and translated front panel cover map, documentation CD (063-4118-xx), OpenChoice Desktop software, NI LabVIEW SignalExpressTM Tektronix LE software, calibration certificate, measurement results traceable to the National Metrology Society and ISO9001 quality certification system, power cord, three-year warranty. The MSO model also includes a P6316 16 channel logic probe and a matching toolbox and accessory package (016-2008-xx).