Beijing Hongzuo Shengwei Technology Co., Ltd
Home>Products>Thermal desorption
Thermal desorption
The ATDS-3420 thermal desorption automatic injection device is a sample pretreatment device that can be used with all imported and domestic gas chroma
Product details
Characteristics and main functions of ATDS-3420 thermal desorption automatic sampling device
1. The function of ATDS thermal desorption automatic sampling device can be configured according to user requirements;
2. Automated design, easy to operate;
3. Microcomputer control, LCD Chinese character display, membrane keyboard, numerical input, main functions include:
⑴ LCD can display: method parameter settings, real-time working status, running time, year month day hour, etc., at a glance;
⑵ Analysis furnace, injection system, and sample transfer tube, all three channels are heated and temperature controlled;
⑶ Three external affairs, 8-level time program control, running self start and self stop;
⑷ It has 9 methods for editing, storing, and calling at any time, achieving fast startup and analysis;
⑸ The GC and chromatographic data processing workstations can be synchronously started, and the device can also be started using external event programs;
The keyboard operation is equipped with a mute function;
The brightness of the LCD can be adjusted according to the usage scenario;
The display board and program control board circuit have self checking function and fault display;
4. Equipped with an external carrier gas regulation system, the GC instrument can be operated without any modification or alteration. If the original instrument carrier gas is used, the device can be regarded as an automatic sampling system module for use;
5. A thermal desorption device can simultaneously supply several GC samples for analysis, greatly improving work efficiency;
6. The sampling tube after thermal desorption has an automatic blowback function;
7. Through foreign affairs time programming, automatic functions such as desorption, injection, analysis, and post analysis blowback can be achieved;
8. For active substance analysis, a 0.53mm elastic quartz tube can be selected as the sample transfer tube;
9. The key components used for driving are imported pneumatic components;
10. There are various specifications of injection needles that can be easily replaced to meet the needs of different GC instrument injection ports;
3、 Main technical performance of ATDS-3420 thermal desorption automatic sampling device
1. Temperature control range in the sample area:
Room temperature -400 ℃, with an increment of 1 ℃, set heating power of approximately 200W;
2. Temperature control range of valve injection system:
Room temperature -160 ℃, with an increment of 1 ℃, set heating power of approximately 60W;
3. Temperature control range of sample transfer pipeline:
Room temperature -160 ℃, with an increment of 1 ℃, the heating power is approximately 40W;
For operational safety, the temperature control of the transmission pipeline adopts low-voltage power supply;
4. Temperature control accuracy:< ±0.5℃ ;
5 Temperature control gradient:< ±0.5℃;
6. Desorption recovery rate:>85% (depending on the composition);
7. Backblowing cleaning flow rate: 0-20ml/min (continuously adjustable);
8. Effective size of the instrument: 170 × 390 × 400mm;
9. Weight of the instrument: approximately 10 kg.
Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!