The Thermo Scientific TRACE 1310 gas chromatograph can help you improve productivity, accelerate response time, and reduce instrument holding costs. With its functional diversity and high performance of GC and GC-MS, it is an ideal choice for large-scale production and QA/QC laboratories and research institutions. The system features a full touch screen design for instrument control, status monitoring, and method development on the instrument. With instant connection to the injection port and detector, you can replace modules, reconfigure different workflows, develop new methods, and save maintenance downtime in minutes.
Introduction:
The Thermo Scientific TRACE 1310 gas chromatograph can help you improve productivity, accelerate response time, and reduce instrument holding costs. With its functional diversity and high performance of GC and GC-MS, it is an ideal choice for large-scale production and QA/QC laboratories and research institutions. The system features a full touch screen design for instrument control, status monitoring, and method development on the instrument. With instant connection to the injection port and detector, you can replace modules, reconfigure different workflows, develop new methods, and save maintenance downtime in minutes.
characteristic:
- Switch between injection port and detector within minutes
- not haveSpecial training or tools are required to switch between the injection port and detector within two minutes
- Significantly reduces maintenance downtime, and samples can be restarted within minutes
- Immediately switch to a different workflow or method
- carryhigh production rate
- Using robust injection port technology, it is rare to clean dirty matrix samples during analysis
- With excellent detector sensitivity and micro volume technology, trace compounds can be analyzed with less injection volume and smaller pre concentration results.
- Adopting optional blowback technology can protect system components and reduce operating time and maintenance
- The use of low heat capacity injection ports and detectors, as well as rapid furnace chamber technology, can shorten the cycle time of sample operation
- Use a range of sample processing options to automate the entire workflow (from pipetting to injection)
- Using Thermo Scientific? Dionex? Chromeleon? Chromatography Data System (CDS) software simplifies and accelerates data analysis
- Reduce equipmentHolding cost
- Reconfigure the module system to meet different requirements, or share injection ports and detectors among several GCs
- Reduce downtime by using tool free modules for easy maintenance
- Allow the use of standard consumables to reduce operating costs
- Energy saving through low heat capacity and fast start
- Reduce sample and solvent consumption with trace sample function
- approachConnect the injection port and detector options at the same time
- Helium saving module
- Split/No Split (SSL); Reverse blowing function is also optional
- Programmed temperature injection port (PTV); Reverse blowing function can also be selected
- Flame ionization detector (FID)
- Thermal conductivity detector (TCD)
- Electron Capture Detector (ECD)
- Nitrogen phosphorus detector (NPD)
- Flame photometric detector (FPD)
- Gas sampling valve
- compatible
- Thermo ScientificTriPlus? RSH automatic sampler
- Thermo ScientificTriPlus 300 Headspace Automatic Sample Injector
- Thermo ScientificTriPlus 100 LS liquid automatic sampler
- Thermo ScientificAI/AS 1310 Automatic Sample Injector
- Thermo ScientificISQ single quadrupole GC-MS
- Thermo ScientificITQGC ion trap MS system (can be deleted, this product has been discontinued by the factory)
- Thermo Scientific TSQ8000 triple quadrupole GC-MS/MS
- Thermo ScientificTSQ Quantum XLS and Thermo ScientificTSQ Quantum XLS Ultra Triple Quadrupole GC-MS System
- Thermo ScientificDFS high-resolution GC-MS
- Thermo ScientificDelta V isotope ratio mass spectrometer
- TRACE 1310 auxiliary furnace box
- authentication
- International Electrotechnical Commission (IEC): 6100-1:2001-61010-2-010:2003-61010-2-081:2001+A1: (2003)
- CAN/CSA C22. 2 No. 61010-1 and UL 61010-1
- European Standard (EN): 6100-1:2001-61010-2-010:04-61010-2-081:2002
- Electromagnetic compatibility (EMC) and radio frequency interference (RFI): CISPR 11/EN 55011:1 Group A and IEC/EN 61326-1:2006