·The three-phase LCD multifunctional power meter adopts advanced microprocessors and digital signal processing technology. Through direct AC sampling, it can measure electrical parameters such as current, voltage, active power, reactive power, power factor, frequency, active energy, reactive energy, etc. It can also be optionally equipped with switch input/output, analog transmission output, power pulse output, etcRS485Network communication function. As an advanced intelligent and digital front-end acquisition component for power grids, this instrument is widely used in various control systems, industrial automation, intelligent buildings, intelligent distribution panels, and switch boxes. It has the characteristics of easy installation, simple wiring, easy maintenance, small engineering quantity, and programmable input parameters on site. Capable of completing different tasks in the industryPLCNetworking of industrial control computer communication software.
Detailed Introduction
summary
Multi functional power meterIt adopts advanced microprocessors and digital signal processing technology, and can measure electrical parameters such as current, voltage, active power, reactive power, power factor, frequency, active energy, reactive energy, etc. through direct AC sampling. It also has optional switch input and output, analog transmission output, power pulse output, and RS485 network communication functions. As an advanced intelligent and digital front-end acquisition component for power grids, this instrument is widely used in various control systems, industrial automation, intelligent buildings, intelligent distribution panels, and switch boxes. It has the characteristics of easy installation, simple wiring, easy maintenance, small engineering quantity, and programmable input parameters on site. Capable of networking different PLCs and industrial control computer communication software in the industry.
TECHNICAL INDEX
transport enter measure measure apparent show |
electricity press |
RATING |
AC100V, 400V (please specify when ordering) |
overload |
Duration: 1.2 times Instantaneous: 2 times/10 seconds |
power consumption |
< 1VA (per phase) |
impedance |
>500KΩ |
accuracy |
RMS measurement, accuracy level 0.5 |
electricity flow |
RATING |
AC 1A, 5A (please specify when ordering) |
overload |
Duration: 1.2 times Instantaneous: 10 times/10 seconds |
power consumption |
< 0.4VA (per phase) |
impedance |
<2MΩ |
accuracy |
RMS measurement, accuracy level 0.5 |
frequency |
45-55Hz, accuracy 0.01 Hz |
power |
Active power accuracy level 0.5, reactive power accuracy level 1.0 |
electric energy |
Active power accuracy level 1.0, reactive power accuracy level 2.0 |
display |
Programmable, switchable, looping (LED/LCD) display |
Electric energy display range |
0.01-KWh (or KVar) |
power supply |
scope of work |
AC/DC 80-270V special requirements can be customized |
power consumption |
<5VA |
input |
Switching input |
4-channel switch input, remote dry contact mode (optional) |
output |
Digital Interface |
RS-485, MODBUS-RTU protocol (optional) |
pulse output |
2-channel power pulse output (optional) |
Switching Output |
4-channel switch output, relay passive contact mode (optional) |
analog output |
4-channel analog transmission output, 4-20mA/0-20mA/4-12-20mA/0-5V/1-5V (optional) |
environment |
work environment |
-10-55 ℃, relative humidity<85%. Non corrosive gas environment, altitude<2000m |
Environment |
-55-85 ℃, relative humidity<85% |
secure |
pressure resistance |
Input/power>2KV, input/output>2KV, power/output>1KV |
isolation |
Input, output, and power supply to the chassis>100M Ω |
List of multifunctional power meter models and functions
model |
measure |
display |
Appearance and installation dimensions |
Peripheral functions (optional, to be specified when ordering) |
A |
B |
C |
D |
E |
digital communication |
Switch Module |
Transmission output |
electric energy pulse |
HL-42K3E |
U、I、KW、KVar、KWh、 KVarh、Hz、cosφ |
LED
|
120
|
120
|
83
|
112
|
112
|
RS-485 MODBUS -RTU |
4-way entry Route 4 departs 4DI/4DO |
4-channel transmission 4-20mA 0-20mA 4-12-20mA 0-5V 1-5V (Optional) |
2-channel electrical energy pulse output |
HL-42K3EY |
U、I、KW、KVar、KWh、 KVarh、Hz、cosφ |
LCD |
120
|
120
|
83
|
112
|
112
|
HL-96K3E |
U、I、KW、KVar、KWh、 KVarh、Hz、cosφ |
LED
|
98
|
98
|
83
|
90
|
90
|
RS-485 MODBUS -RTU |
4-way entry Route 4 departs 4DI/4DO |
4-channel transmission 4-20mA 0-20mA 4-12-20mA 0-5V 1-5V (Optional) |
2-channel electrical energy pulse output |
HL-96K3EY |
U、I、KW、KVar、KWh、 KVarh、Hz、cosφ |
LCD |
98
|
98
|
83
|
90
|
90
|
HL-80K3E |
U、I、KW、KVar、KWh、 KVarh、Hz、cosφ |
LED
|
84
|
84
|
83
|
76
|
76
|
RS-485 MODBUS -RTU |
2-channel switch Quantity output or 2-channel electrical energy pulse output |
4-channel transmission 4-20mA 0-20mA 4-12-20mA 0-5V 1-5V (Optional) |
2-channel switch Quantity output or 2-channel electrical energy pulse output |
HL-80K3EY |
U、I、KW、KVar、KWh、 KVarh、Hz、cosφ |
LCD |
84
|
84
|
83
|
76
|
76
|
HL-72K3E |
U、I、KW、KVar、KWh、 KVarh、Hz、cosφ |
LED
|
75
|
75
|
90
|
67
|
67
|
RS-485 MODBUS -RTU |
2-channel switch Quantity output or 2-channel electrical energy pulse output |
4-channel transmission 4-20mA 0-20mA 4-12-20mA 0-5V 1-5V (Optional) |
2-channel switch Quantity output or 2-channel electrical energy pulse output |
HL-72K3EY |
U、I、KW、KVar、KWh、 KVarh、Hz、cosφ |
LCD |
75
|
75
|
90
|
67
|
67
|
Wiring example diagram
Note: 1 "★" is the current input terminal. Please refer to the product's random wiring diagram for specific wiring methods and parameters.
Order List
When placing an order, please specify in detail the required model, input signal ratio, and expansion function module.
Example 1: Model: HL-42K3E Power Supply: AC220V Input: 10KV/100V 200A/5A Power Network: Three phase three wire
Communication: RS485/MODBUA-RTU Function Expansion: 4DI/4DO Quantity: 88 units