Three phase rail type electric energy meter
Introduction: The DT (S) S238-7 series three-phase rail type electronic energy meter is a new product launched by our company. It adopts advanced dedi
Product details

application

Product use

The DT (S) S238-7 series three-phase rail type electronic energy meter is a new product launched by our company. It adopts advanced dedicated bidirectional energy measurement digital circuit chips and SMT manufacturing technology, used to measure active or reactive energy in three-phase AC circuits. It uses a counter display and is characterized by bidirectional power measurement technology, anti-theft, high precision, high reliability, high overload, low power consumption, light weight, and low cost. Adopting 35mm DIN standard rail installation, in compliance with DINEN50022 standard. 7-pole width (module 12.5m), in compliance with JB/T7121-1993 standard. Widely used in circuit breaker installation boxes and complete sets of equipment.

This product is suitable for use in environments with temperatures ranging from 0-40 ° C to+75 ° C and relative humidity not exceeding 85%.

This product meets all technical requirements for three-phase electronic energy meters in GB/T17882-1999 and GB/T17215.321-2008 standards.


Product Features

Product features



Bidirectional active energy meter, does not require calibration for long-term operation

Three phase power supply, one or two phases of power outage, measurement accuracy is not affected

Wide voltage, current, and operating temperature range

5+1 step counter display or 5+1 6+1 5+2 LCD digital display


start

Start

Under the conditions of rated voltage, rated frequency, and power factor of COS Φ=1, when the load current is active ≥ 0.002Ib (connected through a transformer), non active ≥ 0.003Ib (connected through a transformer), active ≥ 0.004IB (directly connected), and reactive ≥ 0.005Ib (directly connected), the energy meter should be able to continuously measure electrical energy.


shunt running

Defluction

When the circuit is disconnected with 115% rated voltage and current applied, the test output of the energy meter should not generate more than one pulse.


Principle and Function

Principle and function

As shown in Figure 1, the measured three-phase voltage and current are converted into appropriate levels by their respective sampling circuits and input into a dedicated digital integrated circuit for bidirectional energy metering. The output of the circuit is a pulse signal proportional to the measured input active/reactive power, which is divided and used to drive the distributed motor meter for active/reactive power measurement, achieving three-phase energy metering. The electric energy meter has electric energy testing pulses and outputs.
This meter is powered by a three-phase power supply, and can still operate normally in the event of a phase loss (with the phase loss indicator light off indicating phase A, phase B, and phase C, respectively).


Figure 1DT (S) S/DXS238 series three-phase electronic energy meter working principle block diagram


Usage

Usage method

DT(S)S/DXS238The terminal socket wiring of the series three-phase electronic energy meter is shown in the following figure:



(1)DTSDirect wiring diagram of three-phase four wire electronic energy meter


(2)DTSThree phase four wire electronic energy meter with current transformer wiring diagram



(3)DSSDirect wiring diagram of three-phase electronic energy meter


(4)DSSThree phase three wire electronic energy meter with current transformer wiring diagram




(5)DSSThree phase three wire electronic energy meter with current transformer wiring diagram


(5)Schematic diagram of electrical energy test output




connecting terminal

describe

L1

L1phase line(A(Xiang)

L2

L2phase line(Beach other)

L3

L3phase line(Ceach other)

N

neutral line(zero line)

15and16

Passive remote control power pulse output(This feature can be customized forAMR)

7and8

Passive short-range electrical energy pulse output

9.11and13

Voltage function terminal, only used when the electric energy meter is connected through a current voltage transformer


Installment and use

Installation and use


Rated frequency: 50Hz/60Hz
Power consumption: Voltage circuit ≤ 1W and 10VA (single-phase)
Power consumption:Current circuit ≤ 1VA (single-phase)
Environmental conditions: calibrated working temperature -25~+55 ℃
Environmental conditions: Maximum operating temperature -40~+70 ℃
Environmental conditions: Relative humidity ≤ 85%
Net weight: Three phase three wire approximately 0.6kg Three phase four wire approximately 0.7kg



productmodel

accuracygrade

specifications

Electric energy testingPulse constant

DT(S)S238-7

Merit 1.0

DSS238-7 three-phase three wire 3X100V

3X380V

3X1.5(6)A

The pulse constant is based on the energy meter panel representation

3X5(20)A

3X10(40)A

3X15(60)A

3X20(80)A

DTS238-7 three-phase four wire 3X220/380V

3X1.5(6)A

3X5(20)A

3X10(60)A

3X57.7/100V

3X20(80)A

3x57.7/100v

3x1.5(6)

Basic error

Active power level 1.0, reactive power level 2.0