brand | CNSHP/Shanghai Equity | Maximum pressure | 2900Psi |
---|---|---|---|
maximum temperature | 500℃ | microwave source | magnetron |
Number of samples | 42 pieces/batch | Furnace cavity level | Industrial grade |
Price range | 200000 to 300000 | Origin category | domestic |
application area | petroleum |
Titan-42 high-throughput closed intelligent microwave digestion instrument
Product Introduction:
TITANThe series of high-throughput enclosed microwave digestion/extraction platforms are built with the years of experience and industry technology of the company's technical personnel, and are widely applicable to microwave working platforms under extreme laboratory conditions. The TITAN series focuses on the development trend of microwave digestion/extraction/synthesis systems, achieving high-quality working effects to a large extent while ensuring safety.
The microwave digestion instrument is the first step in the analysis process, and the TITAN series is a microwave equipment that carries the enthusiasm of the company's technical personnel, relevant field knowledge, and future detection instrument needs, in order to better serve the vast number of scientific and technological workers. The TITAN series adheres to the concept of easy operation, safety, efficiency, and durability, integrating instrument hardware, operating software, monitoring methods, and high-pressure tanks.
*Security monitoring system:
TITANThe series of independent innovations adopts multiple safety monitoring systems, which can observe and monitor all situations in the microwave cavity in real time from the terminal, providing operators with safety monitoring at any angle and distance.
Terminal panel door light monitoring, intelligent door lock self-test system, prevents the door from being opened arbitrarily, with excellent protection level!
Terminal panel microwave light monitoring, microwave emission status monitoring, whether the microwave is working properly is clear at a glance.
Terminal panel turntable light monitoring, rotor operation status monitoring, once abnormal, immediately alarm and terminate instrument operation. At the same time, it also provides positive information. The observation window provides safety monitoring for the operator *.
Terminal panel button light monitoring, button status detection, and clear indication for any operation.
Aerospace composite fiber explosion-proof outer tank superior to similar products:
The explosion-proof outer tank made of our company's unique fully enclosed aerospace composite fiber material has super strong pressure resistance and anti-corrosion performance, which is superior to the commonly used organic modified PEEK engineering plastic in the market. It solves the problems of PEEK material melting easily at high temperatures, not being resistant to acid erosion, and having fragments during damage. The fully enclosed design avoids the disadvantages of similar products having open top and bottom, being easily penetrated by acid gas, and becoming loose and deformed over time. Our company adopts the process of spraying PFA to completely wrap the composite fiber tank body, achieving better anti-corrosion effect, with a pressure resistance of up to 85MPa (12500psi), which is currently an excellent product in the industry. Equipped with three-dimensional directional explosion-proof technology and multiple active and passive safety measures to ensure personnel safety.
Titan-42 high-throughput closed intelligent microwave digestion instrument
Other technologies:
Unique and stylish touch sensitive intelligent panel.
The instrument adopts professional PID control theory and utilizes high-performance microprocessors and new sensing technology to achieve precise closed-loop control of microwave power on temperature and pressure.
Piezoelectric crystal pressure measurement technology, non-contact pressure measurement, the pressure measuring element is completely isolated from the sample, there is no cross contamination, and the operation is simple. The efficient non pulse microwave power automatic frequency conversion control technology improves the microwave emission efficiency of the magnetron, saving energy and efficiency.
The digestion rotor rotates continuously in one direction inside the furnace cavity, avoiding uneven microwave heating caused by rotor stoppage during back and forth rotation, reducing impact on the motor, and extending its service life.
Technical parameters:
model |
Titan-42 |
Titan-60 |
Resonant cavity volume |
≥ 70L ultra large capacity 316L stainless steel dedicated industrial grade furnace chamber, surface sprayed with 8 layers of PTFE treatment |
≥ 70L ultra large capacity 316L stainless steel dedicated industrial grade furnace chamber, surface sprayed with 8 layers of PTFE treatment |
Maximum microwave power |
Industrial grade dual magnetron microwave output 0-2000W, non pulse continuous automatic frequency conversion control, total installed power 3200W |
Industrial grade dual magnetron microwave output 0-2000W, non pulse continuous automatic frequency conversion control, with a total installed power of 3200W, |
temperature control system |
High precision platinum resistance temperature control system/fiber optic temperature control system |
High precision platinum resistance temperature control system/fiber optic temperature control system |
Display/button |
High resolution color LCD screen/color touch LCD screen Inductive touch button, professional control circuit, better anti-corrosion and higher reliability |
High resolution color LCD display screen/color touch LCD screen with inductive touch buttons, professional control circuit, better corrosion resistance, and higher reliability |
turntable
|
360Unidirectional rotation, independent ball turntable system/combined ball turntable system |
360Unidirectional rotation, combined ball turntable system
|
Batch processing Quantitative analysis |
1-42tank |
1-60tank |
tank rack |
Independent framework type ultra-high pressure digestion tank rack,zHigh withstand pressure ≥ 100Mpa |
High pressure combined digestion tank rack,zHigh withstand pressure ≥ 65Mpa |
Inner tank volume |
Imported modified polytetrafluoroethylene (TFM) material, digestion tank capacity 100ml, ZtallWork pressure ≥ 6MPa, ZtallEnduring pressure ≥ 15MPa (2200psi), ZtallTemperature tolerance ≥ 300 ℃ |
Imported modified polytetrafluoroethylene (TFM) material with a digestion tank capacity of 100ml zHigh working pressure ≥ 6MPa,zHigh withstand pressure ≥ 15MPa (2200psi),zHigh temperature resistance ≥ 300 ℃ |
Outer tank material |
Imported high-strength aerospace composite fiber materials/high-strength reinforced polyether ether ketone (PEEK) special engineering materials,zHigh pressure resistance ≥ 85 MPa. |
Imported high-strength aerospace composite fiber materials/high-strength reinforced polyether ether ketone (PEEK) special engineering materials,zHigh pressure resistance ≥ 85 MPa. |
Supporting product: MTC-II electric heating digestion instrument
The microcomputer temperature controlled electric heating digestion instrument (MTC-II) uses digital circuit PID technology to control temperature, which has the advantages of safety, reliability, fast digestion, high efficiency, and convenience. Can be used independently for electric wet digestion, with the advantage of being an auxiliary equipment for microwave digestion systems; Suitable for pre-treatment of samples with large sample sizes, strong chemical reactions, organic solvents, and unknown components before closed microwave digestion, and can also be used for acid removal tasks after microwave digestion is completed. Program temperature automatic adjustment and control of heating rate and insulation power matching.
Main features and advantages:
Adopting PID temperature control technology, the temperature control accuracy is high, the temperature difference is small, and the heat conduction efficiency is high.
The 5-step program can be heated up to meet the needs of users in different industries as much as possible.
Adopting three-dimensional surround heating, the temperature is continuously adjustable, the controllable temperature is constant, and 15 samples are digested simultaneously. The sample digestion effect is excellent, and the instrument operation is simple.
The whole machine is designed with multi-layer PTFE coating, which is corrosion-resistant and high-temperature resistant.
Target temperature and real-time temperature are displayed simultaneously, and working time and running time are displayed simultaneously.
Technical indicators:
power supply |
power |
temperature range |
Control accuracy |
Heating method |
processing capacity |
External dimensions |
net weight |
220VAC±10% 50Hz |
2000W |
Room temperature~250linear measure |
±0.1℃ |
electrical heating |
15/write instructions or comments on |
360*333* 142(mm) |
11.8kg |