HY-20ATransparent Deoxygenation Tube (Gas Consumable)
overview:
HY-20ATransparent Deoxygenation Tube (Gas Consumable)The specification isФ30mm×270mmThe form is divided into stainless steel type and organic glass type(Color changing transparent)Two types can remove residual oxygen, moisture, and hydrocarbons from the carrier gas.Organic glass deoxidation tube with high-efficiency palladium metal inside-Oxide system deoxidizer, with oxygen adsorption capacity *, can directly remove impurity oxygen from gases such as nitrogen, argon, helium, methane, carbon monoxide, ethylene, etc. at room temperature, making the residual oxygen less than1ppmAt the same time, it can also remove impurities such as water and carbon dioxide. It is an effective device for all anaerobic operations.Used for gas chromatographyECDThe high-purity nitrogen deoxygenation and strong polarity chromatography column carrier gas deoxygenation of the detector can improve the service life of the chromatography column and make the analysis results more accurate.
matters needing attention:
- The deoxygenation tube is tightly packed with deoxygenation agent particles, and should not be forcefully bumped or knocked during installation and use.
- The inlet gas pressure of the deoxygenation tube shall not exceed0.5Mpa, Zui high traffic5L/min.
- The plugs and nuts at both ends of the deoxygenation tube should not be loosened before use to prevent air from spreading into the interior of the deoxygenation tube and causing it to quickly fail.
- Stainless steel can be regenerated on its own. The labeled end is the entrance, following the original flow direction and cannot be reversed. Before regeneration, remove the label, and after regeneration, stick the label in its original direction.
- Familiarize yourself with the installation program before installation and use, and prepare as required.
- Deoxygenation capacity (calculated based on pure oxygen) is5Raise. And it can regenerate itself.
Regeneration
The deoxygenation tube is equipped with a color changing deoxygenation agent. The new deoxygenation tube is green, and as the deoxygenation agent adsorbs oxygen, it gradually turns black in the direction of the airflow. When all the deoxygenation agent turns black, the adsorbed oxygen reaches saturation and has lost its deoxygenation ability. Generally, high-purity nitrogen gas is used(99.999%)2~3After the bottle needs to be regenerated, ordinary nitrogen can only be used in one bottle, so it is recommendedUse high-purity gas.
After the deoxygenation tube fails, install the original plug and send the deoxygenation tube back to our company,Re activation or trade in will be offered at a discounted price.