Guangzhou Quanfeng Environmental Protection Equipment Co., Ltd
Home>Products>Turbidity and Sludge Concentration Meter TC-7100
Firm Information
  • Transaction Level
    VIP member
  • Contact
  • Phone
    1392422246313318771005
  • Address
    3rd Floor, Building 1, Zhanqing Industrial Park, Haiyong Road, Panyu District, Guangzhou City
Contact Now
Turbidity and Sludge Concentration Meter TC-7100
Widely used in sewage treatment, circulating water monitoring, reclaimed water reuse, and discharge of water, surface water
Product details

application

Widely used in sewage treatment, circulating water monitoring, reclaimed water reuse, and discharge of water, surface water

Water quality monitoring and other fields

characteristic

144X144 microcomputer designed turbidity/suspended solids/sludge concentration transmitter

Outdoor waterproof design suitable for wall mounted, panel mounted, and circular pipe installation

Large LCD display screen with operation status and special symbol display

Equipped with backlight sensor, automatic and manual backlight setting function

Can be paired with Turb/SS/MLSS electrodes of various ranges

■ Provide electrode automatic cleaning device contacts, program setting output

■ Equipped with two-point or three-point correction and offset value correction functions

Password lock and combination key enter the setting and calibration mode design, enhancing security protection

Equipped with RS-485 interface output and Modbus standard communication protocol

■ Set Turb/SS/MLSS corresponding to 0/4~20mA output

specifications

■ Measurement range

TC-7100

Turb: 0.00~100.00/500.0/3000NTU

SS: 0.0~1000.0mg/L

TC-7100-M

MLSS: 0.000~50.0g/L

■ Resolution

TURB: 0.01/0.1/1NTU

SS: 0.1mg/L

MLSS: 0.001g/L

■ Instrument accuracy

TURB: 3%±1 Digit

SS: 3%±1 Digit

MLSS: 3%±1 Digit

Correction mode 1-5 point correction, offset value correction

Working temperature: 0 ℃~50 ℃

Storage temperature -20~70 ℃

■ Large LCD display screen

■ Analog output isolated 0/4~20mA output

Program settings correspond to Turb/SS/MLSS

■ Digital output RS485 Modbus standard communication protocol

Relay output high and low points, hysteresis can be set by any program

Two sets of ON/OFF outputs

240VAC maximum current 0.5A

■ Cleaning contact: ON 0~9999 seconds/OFF 0~999.9 hours

A set of ON/OFF outputs

240VAC maximum current 0.5A

■ Power input 100-240VAC wide power supply, 50/60Hz

Installation methods include wall installation, panel installation, and circular pipe hanging installation

■ Instrument size 144mm × 144mm × 115mm (H × W × D)

■ Hole size 138mm × 138mm (H × W)

■ Protection level IP65

■ Weight 0.8Kg

Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!