Product functional features
※ Small size, unrestricted installation position and direction, easy operation;
※ Automatic shutdown for overpressure, undervoltage, and overcurrent, with fast response speed;
Good shutdown performance, safe and reliable;
※ Non energy consuming, pollution-free, energy-saving and environmentally friendly, maintenance free;
Product Technical Parameters
Product Selection

Self closing valve - Operating safety instructions
The operation of the pipeline gas safety self closing valve (self closing valve) is relatively simple. After automatic closure, first check the reason for closure, and then pull up the reset lever.
When the following situations occur, the self closing valve will automatically close. Before resetting, please investigate the cause and then reset the self closing valve to avoid accidental losses.
1. The gas company will automatically shut down after stopping gas supply. 2. The gas company's pipeline will automatically shut down due to overpressure. When the rubber hose of the gas stove falls off or burns out, it will automatically close.
Self closing valve - quarterly safety inspection recommendations
After the installation or normal use of the self closing valve, it is recommended to conduct a leak detection every three months. The method is: apply foam made of soapy water, etc. to the self closing valve
Check for gas leaks at the inlet and outlet threads and reset rods. If there are leaks, please call the local gas company for repair.