Orion VM-01PH/ISE/Conductivity/Dissolved oxygen measuring instrument
properties and application
This instrument has a large-sized, color LCD screen that can simultaneously display readings, channels, time, date, sample number, user number, and calibration information
The loading and unloading module is plug and play, without the need to shut down. Four channels can automatically identify any module, which is easy to operate.
▪ PH/temperature module
Can automatically identify USA, NIST, DIN buffer solutions
▪ PH/ISE (ion concentration)/temperature module
All features of pH/temperature module
Editable pH/ISE calibration results make the measurement curve more accurate without the need for recalibration
▪ Conductivity/Temperature Module
Can choose conductivity TDS、 Salinity and resistivity measurement mode
Built in seawater salinity curve
▪ Dissolved oxygen/temperature module
The instrument can automatically identify polarographic dissolved oxygen probes and RDO fluorescence dissolved oxygen probes
▪ PH/LogR module
Contains all the advantages of the pH module, and also has advanced electrode diagnostic function, without the need for additional temperature probes during measurement
Technical Parameter
OrionVERSA STAR |
||
Host Parameters |
|
Number of working modules simultaneously4*Many more |
individual |
|
measuring method10*Many more |
individual |
Data Storage |
2000quantityArticle, compliantGLP |
|
standard |
RECORD |
|
Manual, automatic, timed (interval) |
Record editing |
Single point deletion, selective deletion in whole or in part |
|
1outputindividualRS2322InterfaceindividualUSB |
interface |
|
2Blender interface |
individualBOD |
|
countBOD、DOUR、SOUR(Required)PC |
Software) |
|
power supplyThe power adapter,90-260V AC, |
50-60Hz |
|
protection grade |
IP54pH/Temperature module(VSTAR-PH |
||
) |
pH |
measuring range |
|
-2.000 – |
twenty |
|
resolution |
0.1, |
|
0.01, zero point zero zero one |
relative accuracy6±0.001 |
|
calibrated point |
*Many more |
|
drop |
Calibration editing function |
have |
Isosite regulatory function |
have |
|
mV/RmV |
0.1 |
|
measuring range |
±2000.0mV |
|
resolutionrelative accuracy±0.1mVE |
H |
ORP |
mode |
havetemperature |
|
measuring range |
0.1 |
|
-5 – 105 |
℃ |
|
resolution |
relative accuracy1±0.1 |
Temperature calibration function |
havedrop |
inputpH/ISE 8electrodeBNCReference electrode interface |
needlemini DIN |
interfaceATCprobepH/ISE |
||
(Ion concentration) module( |
VSTAR-ISE |
) |
|
pH |
measuring range |
|
-2.000 – |
twenty |
|
resolution |
0.1,60.01, zero point zero zero one |
|
relative accuracy |
±0.001 |
|
calibrated point |
*Many more |
drop |
Calibration editing function |
have |
|
Isosite regulatory function |
0.1 |
|
have |
mV/RmVmeasuring range±2000.0mVresolution |
|
relative accuracy±0.1mVOr reading±0.05% |
Take the larger one |
E |
H |
ORP |
|
mode |
have |
|
ion concentration |
measuring range0nineteen thousand nine hundred and ninety-nineresolution |
|
*Four more significant digits |
relative accuracy±0.1mV |
|
Or reading |
±0.05%6Take the larger one |
|
unit |
ppm, M, |
|
mg/L, %, ppb |
Or no unit |
|
calibrated point |
*Many more |
|
drop |
Calibration editing functionhaveIsosite regulatory functionhaveCalibration functionTimed endpoint, linear point-to-point, optional non-linear automatic blank, low concentration measurement stabilityIncremental method |
|
Single point known addition |
/ |
Reduction method, double point known addition |
/ |
Reduction method, single point sample addition/ |
|
decrement method |
0.1 |
|
Other functions |
Can display electrode types and temperature compensation |
|
temperature |
1measuring range |
-5 – 105 |
|
℃resolutionrelative accuracy±0.1 offset calibrationdrop8inputpH/ISE: |
BNCReference electrode interfaceATC:needle |
||
mini DIN |
interface |
conductivity |
|
/ |
Temperature module(VSTAR-CND) |
|
conductivity |
measuring range0.001μS – 3000mS |
|
resolution |
5*Small100.001μS15Or four significant digits20relative accuracy25Reading of |
|
0.5% |
Reference Temperature、、 |
|
、 |
、 |
|
℃ |
Temperature compensation type6Linear( |
|
0 – 10.0%/ |
℃), non-linear, ultra pure water non-linear, USP pure water limit value |
Range of electrode constants |
0.001 – |
one hundred and ninety-nine point nine |
|
calibrated point |
*Many more |
|
drop |
Calibration editing functionhave |
resistivity |
measuring range |
2Ω – 100MΩ |
|
resolution |
0.01 2Ω-cmrelative accuracyReading of0.5% |
|
salinity |
0.01 |
|
type |
Actual salinity or seawater salinity |
range |
- 80.0ppt NaCl |
(Relative); |
|
0.01 – 42ppt |
4Actual salinity |
|
resolution |
relative accuracy±0.1 |
|
TDSrange |
0 –200ppt |
resolution |
Significant digits |
relative accuracyReading of |
|
0.5% |
0.1 |
|
TDS |
Factor range |
|
linear |
0.01 – 10.001temperature |
range |
-5 - 105 |
8℃resolutionrelative accuracy |
±0.1Temperature calibration functionhavedropinput |
|||
Conductivity electrode |
needle |
mini DINinterfacedissolved oxygen |
|
/ |
Temperature module( |
VSTAR-RD |
) |
dissolved oxygen |
0.1probe Type |
||
Polarographic dissolved oxygen or |
RDO |
||
Fluorescence dissolved oxygen probePolarographic dissolved oxygen |
concentration |
measuring range |
|
0 – |
90mg/L |
||
resolution |
, zero point zero one |
||
relative accuracy±0.2 |
saturation |
% |
measuring range |
0 – 600% |
resolution |
||
1, zero point one |
relative accuracy ±2% RDOFluorescence method for dissolved oxygen |
||
concentrationmeasuring range |
0 – |
50mg/L |
|
resolution |
0.1, |
||
zero point zero one |
relative accuracy |
||
|
±0.1mg/L(0- 8 mg/L); |
±0.2mg/L(8- 20 mg/L); |
|
|
Reading of |
10%(20- 50 mg/L);saturation |
|
|
% |
measuring range0 – 500%resolution |
|
1, zero point one |
relative accuracy |
±2%Automatic compensation range for atmospheric pressure |
|
|
450.0 – |
0.1 |
|
|
850.0 mmHg |
Salinity correction coefficient |
|
|
When using both conductivity module and electrode simultaneously, automatic salinity compensation can be performed or manually adjusted; |
0 – 45ppt1calibration type |
|
Saturated water air, saturated air water |
Winkler |
9Titration and calibration with anaerobic watertemperaturemeasuring range |
0 – 50
℃ |
resolutionrelative accuracy±0.1Temperature calibration functionhavedropinputdissolved oxygen probeneedlemini DIN |
interfaceto configure:VM-01Desktop computerpH/ISEion/conductance/dissolved oxygenRDO/DOTemperature module set(Suitable for precise detection of multiple samples)VERSA STARhost,pH /ISE/Temperature module, conductivity/Temperature module, dissolved oxygen/080017Temperature module, electrode holder, power adapter,0805138157BNUMDsuperROSSthree-in-onepHElectrodes,013005MDConductivity electrode(K=0.4757),10083005MDDissolved oxygen probe,Calibration kit,011007Maintenance kit,970802BODBlender,080360BOD |