Volumetric crude oil metering pry can be widely used in the petroleum industry, which can automatically or manually measure the flow rate of crude oil, natural gas, water, as well as temperature, pressure and other information in real-time according to the settings of each well. It can effectively improve the level of automation construction and management in oil fields, save construction and operation costs, reduce labor intensity, and is an ideal product for realizing a "digital oil field".
Due to the fact that the fluid in a single well or well group is actually multiphase flow and the flow state is also very complex, this volumetric crude oil metering pry can solve the complex multiphase flow problem into a single gas phase and liquid phase (oil-water) two-phase problem. Measure the phase separation flow rate and water content of oil, water, and gas using a flow meter.
2. Simultaneously measure online water content, gas content, instantaneous and cumulative flow rates.
3. Thoroughly separate gas and liquid to meet measurement requirements.
4. The flowmeter is not affected by pressure flow state or temperature.
5. Anti sand, anti blocking, self flushing, electric heat tracing insulation, anti scaling, anti wax.
6. Fully digitized and highly automated.
7. Complementary advantages to reduce costs.
8. No civil engineering work is required to establish an automated metering station.
9. It can achieve unmanned operation and remote data transmission.
Crude oil volumetric metering pry can accurately measure crude oil, high pour point oil, high water content crude oil and other fields. It can ensure thorough separation and efficient metering of complex flow state crude oil liquids.
Explosion proof grade: la II CT6 ; Protection IP56
Nominal diameter: DN50mm
Accuracy: ± 0.2%, ± 0.5%
Flow range: 4~40m ³/h
Environmental temperature:- 30 ~ 50℃
Nominal pressure: 4.0MPa
Applicable media: crude oil, high pour point oil, high water content crude oil
Indication function: on-site display of cumulative flow and instantaneous flow
Output: Pulse, 4-20mA
Connection method: flange GB/T9113.1-2000
Technical standard: JB/T9242-1999 Volumetric flowmeter