WSSX-481B explosion-proof electric contact bimetallic thermometer
The WSSX-481B explosion-proof electric contact bimetallic thermometer can directly measure the temperature of liquid, steam, gas media, and solid surf
Product details

Technical Parameter
Scale dial nominal diameter: 100
Thermal response time: ≤ 40S
Explosion proof level: dIIBT4
Rated power: 10VA
Maximum worker voltage: dIIBT4
Maximum working current: 0.7A

Model Temperature measurement range ℃ accuracy class Protection and materials L Install fixed devices
WSSX-410B -80~+40-40~+800~500~1000~1500~2000~3000~4000~500 1.5 1Cr18Ni9Ti 304 316 316L Hastelloy C-276 75 100 150 200 300 400 400 500 750 1000 No fixed device
WSSX-480B
WSSX-411B Movable external thread
WSSX-481B
WSSX-412B Movable internal thread
WSSX-482B
WSSX-413B Fixed thread
WSSX-483B
WSSX-414B Flange
WSSX-484B
WSSX-415B Ferrule thread
WSSX-485B
WSSX-416B Card sleeve flange


Use, maintenance, and overhaul
1. The instrument should be installed in the surrounding environment of -25 ℃~55 ℃, with a relative temperature not exceeding 85% and an altitude below 2000m. At the installation location, the monthly average temperature should not exceed+30 ℃. Due to temperature changes, frost is allowed to form on the surface of the pressure gauge, and the temperature of the measured medium should be less than 70 ℃. (If used for measuring high-temperature media such as steam, a temperature resistant and explosion-proof electric contact thermometer should be selected).

2. The instrument must be installed vertically and strive to maintain the same horizontal position as the measuring point, otherwise additional errors caused by liquid level differences should be included.

3. After connecting the electrical circuit of the instrument, carefully check and perform a trial operation.

4. The instrument pressure section generally uses a temperature upper limit of 3/4.

5. When adjusting the instrument order (adjust the upper and lower limit pointers to the given value by adjusting the knob), adjust the offline set value first and then the online set value.

6. When opening the outlet box or adjusting the given value range, the power must be cut off before proceeding.

model:
WSSX-410B/WSSX-480B/WSSX-411B/WSSX-481B/WSSX-412B/WSSX-482B/WSSX-413B/WSSX-483B/WSSX-414B/WSSX-484B/WSSX-415B
WSSX-485B/WSSX-416B
Temperature measurement range:- 80~+40-40~+800~500~1000~1500~2000~3000~4000~500
Accuracy level:Level 1.5
Protection and materials:
1Cr18Ni9Ti 304 316 316L Hastelloy C-276
Length:
L=75/100/150/200/300/400/400/500/750/1000
Installation of fixed devices:
No fixed device
Movable external thread
Movable internal thread
Fixed thread
Fixed flange sleeve thread
Card sleeve flange

Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!