water/Air cooled industrial chillers use air or water as the cooling medium for the condenser,Industrial cooling equipment using water as a refrigerant Widely used in plastics Electronic Equipment process cooling in various industrial fields such as food, medicine, electroplating, chemical industry, printing, coating, laser, new energy, environmental protection, and optical disc production. According to the different cooling media, industrial chillers are divided into air-cooled industrial chillers and water-cooled industrial chillers, which customers can choose according to their on-site conditions; water/The air-cooled industrial chiller can be equipped with a built-in chilled water pump and water tank, minimizing on-site installation work. Only the inlet and outlet pipes of the unit need to be connected to the equipment in use; Equipped with a stainless steel water tank, it can automatically adjust the water flow in the water pipeline and achieve automatic replenishment and overflow; At the same time, it can effectively buffer water temperature fluctuations caused by changes in usage load and stabilize the operation of the refrigeration system; The compressor is a fully enclosed scroll compressor (or piston type) imported from Europe and America, which has low vibration, strong resistance to liquid impact, high efficiency, and a wide working temperature range; Intelligence: For units with multiple compressor heads, the microcomputer will automatically remember the operating time of each compressor, and the compressor with less operating time will be activated first during the next start-up; Similarly, when it is necessary to unload and run, priority will be given to unloading and shutting down units that have been running for a longer period of time, in order to achieve the average performance of each compressor Run steadily to extend the service life of the entire machine; Stability: Nuobing integrates globally renowned supplier resources to order each unit component Ensure the high quality of each component of the unit To ensure the stability of the overall quality of the machine. Wide: In order to meet the different temperature requirements of industrial cooling and freezing in various industries, different series of scroll type industrial dedicated compressors are used, and the chilled water temperature ranges from 1 5℃ ~- 3 5℃, excellent craftsmanship ensures stable operation under extreme conditions; water/Air cooled industrial chillers can achieve various low-temperature water supply. After adding appropriate antifreeze on the chilled water side, it can achieve0~- 3 5The outlet temperature of ℃ is usually achieved by using antifreeze solvents such as ethylene glycol Sodium chloride and calcium chloride solutions are recommended for customers to set different concentrations of antifreeze solutions based on the outlet water temperature during application Please refer to the attached table for the freezing points of various solutions; Efficient: The unit adopts an internationally advanced fully enclosed vortex type industrial refrigeration dedicated compressor, which significantly improves the compression efficiency of the compressor and the heat exchange efficiency of the heat exchanger High, ensuring efficient operation of the unit. Energy saving: The unit adoptsNUOBINGThe independently developed energy-saving control program ensures that the unit operates automatically according to the set working conditions, maximizing the smooth and energy-saving operation of the unit. Simplicity: The unit structure is simple and has a good human-machine interface. Within the safe operating range of the unit, the operating conditions of the unit can be freely set. Once set, the water-cooled industrial chiller can operate on its own and adjust its energy in real time, making it easy to operate. Anti corrosion: The evaporator of the low-temperature saltwater type unit is processed with imported high-efficiency anti-corrosion materials, which are not ordinary materials for anti-corrosion treatment, ensuring the service life without affecting the heat transfer efficiency and effectively avoiding permanent damage to the unit caused by perforation of the evaporator due to corrosion of the refrigerant. Safety: The unit has a complete protection system, all water/The faults of air-cooled industrial chillers are displayed in both Chinese and English on the operation screen, effectively avoiding damage to the unit under harsh working conditions, protecting the safe operation of the unit, and extending its service life. Standard protections include: compressor overload protection, compressor overheating protection, water pump overload protection, cooling fan overload protection (air-cooled type), refrigeration system high pressure protection, refrigeration system low pressure protection, insufficient water flow protection, anti freezing protection, anti frequent start protection, and power phase error and undervoltage protection. The vortex generator adopts an independent modular design to achieve free combination of capacity, easy to use, and high reliability. Environmental Protection: To Better Protect the Atmosphere Except for usingH C F C 2 2In addition to refrigerants, it is also possible to useH F C 4 0 7 CandH F C 1 3 4 aLow temperature chillers can also be selected as specialized onesH F C 4 0 4 AWaiting for green and environmentally friendly refrigeration media; Our company has a well-equipped testing center Each product is filled with refrigerant and refrigeration oil before leaving the factory, and undergoes strict simulation of standard operating conditions and maximum operating condition testing; Adjust the expansion valve to the optimal state; Our company accepts water with various special process requirements/Customized air-cooled industrial chillers can be customized for explosion-proof, strong acid, strong alkali solutions, ultra-low temperature, and abnormal voltageT 3Non standard products such as working conditions,Contact relevant personnel of our company at any time. |