1、 Overview of water-cooled xenon lamp tube:
Q-LAB Corporation in the United States offers low-cost alternatives that can be used to replace Atlas Weather Meter ® Water cooled xenon lamp tubes and light filters, such as Ci35, Ci35A, Ci65, Ci65A, Ci4000, and Ci5000, as well as SUNTEST CPS/CPS+, Q-LAB water-cooled lamp tube output spectra and Atlas Weather Meter ® The lamp tubes are basically consistent and widely comply with ISO, ASTM, SAE, and AATCC standards.

II Water cooled xenon lamp tube model:
X-6500 water-cooled xenon lamp tube
The water-cooled xenon arc lamp tube X-6500 produced by Q-LAB in the United States can ensure that the output spectrum matches the output spectrum of the 6500 watt tube (part number Atlas 20-6500-00) of Atlas Ci4000. The spectral energy distribution after filtering with its corresponding filter is exactly the same as that provided by Atlas. Can X-6500 water-cooled xenon lamp tubes be installed on Atlas Weather Ometers? On devices such as Ci35, Ci35A, Ci65, Ci65A, and Ci4000.
X-12000 water-cooled xenon lamp tube
The X-1200 water-cooled xenon lamp tube produced by Q-LAB in the United States has the same spectrum as the Atlas 20-3053-00 lamp tube and can be installed in Atlas Weather Ometer ™ On the Ci5000 device. Q-LAB water-cooled xenon lamp tubes widely comply with ISO, ASTM, SAE, and AATCC standards.
X-1500 water-cooled xenon lamp tube
The X-1500 and Atlas 56-0017-94 lamps produced by Q-LAB in the United States have the same spectrum and can be installed in Atlas Weather Ometer ™ On CPS and CPS+devices. Q-LAB water-cooled xenon lamp tubes widely comply with ISO, ASTM, SAE, and AATCC standards.
III The water-cooled xenon lamp tube meets the standard
The water-cooled xenon lamp meets the following standards:
ISO 105 B02 、ISO 105 B04 、ISO 104 B06 、ISO 4892.2 、ISO 11341 、 ASTM G155 、SAE J1960 、 SAE 1885 、SAE 2412 、 SAE 2527 、AATCC TM 16-3 、 AATCC TM 186。
4 Advantages of water-cooled xenon lamp tube:
● Lower operating costs
The price comparison between Q-LAB's replaceable water-cooled lamps and light filters and the Atlas list shows substantial savings.
Because water-cooled xenon lamp tubes and light filters need to be replaced regularly to ensure reliable test results, using Q-LAB replaceable water-cooled xenon lamp tubes and light filters can greatly reduce operating costs.
The same spectrum
When using the same light filter, Q-LAB's X-6500 tube and Atlas 20-6500-0 tube have the same spectrum. Q-LAB's X-12000 and Atlas 20-3053-00 lamps have the same spectrum. Q-LAB's X-1500 and Atlas 56-0017-94 tubes have the same spectrum. As shown in the following figure:
Comparison of X-1500 water-cooled lamp spectra:
Comparison of X-12000 water-cooled lamp spectra:
Comparison of X-6500 water-cooled lamp spectra:
Spectral comparison of optical filters:
● Compatibility and interchangeability
The water-cooled and air-cooled xenon lamp tubes and light filters produced by Q-LAB company are fully compatible and interchangeable with the Atlas aging chamber models mentioned above. The lamps and filters provided by Q-LAB ensure the same spectrum and offer comprehensive warranty. All light tubes are ozone free. The lamp tube and light filter comply with the requirements of ISO, ASTM, SAE, and AATCC. The description, accessory numbers, and matching Atlas models of the lamp tube and light filter are as follows:
● Comprehensive warranty
Each Q-LAB water-cooled xenon lamp tube has undergone lighting testing and strict mechanical and electrical specification inspections. Q-LAB guarantees that it can be continuously used for 1500 hours under normal operating conditions within 24 months from the date of purchase.
Q-LAB guarantees that replaceable filters meet all size and optical specification requirements and will maintain the same spectral power distribution as Atlas within the recommended filter lifespan (400 hours for the inner filter and 2000 hours for the outer filter).
Note: Damage caused by improper use, misoperation, or equipment failure is not covered by the warranty.
Five Precautions for using water-cooled xenon lamp tubes:
When the light intensity or blackboard temperature cannot meet the set requirements, the lamp tube needs to be replaced.