With strong scientific research capabilities and years of experience in water quality monitoring, Lianhua Company has independently designed and developed multiple product series. Including: COD analyzer, ammonia nitrogen analyzer, total phosphorus analyzer, total nitrogen analyzer, BOD5 analyzer, heavy metal analyzer, multi parameter water quality analyzer, water quality online monitoring instrument, etc. Welcome to inquire by phone.
1. Measurement range: 5-2000mg/L (beyond dilution determination)
2. Indication error: ≤ ±8 %
3. Repeatability: ≤ 3%
4. Anti chlorine interference: ≤ 2000mg/L
5. Temperature control system: Room temperature~180 ℃ can be set, and the digestion temperature is 165 ℃.
6. Temperature control accuracy: ± 0.5 ℃
7. Temperature control time: adjustable from 1 to 999min
8. Dissolution time: 15min
9. Optical stability: The instrument's absorbance value drifts less than 0.002A within 20 minutes
10. Batch processing capacity: 12 water samples
11. Dimensions: Host: 240mm×205mm×170mm
Dissolver: 240mm × 107mm × 170mm
12. Weight: 3kg for mainframe, 4kg for digestion analyzer
13. Power consumption:< 500W
14. Normal usage conditions:
⑴ Environmental temperature: 5-40 ℃ ⑵ Relative humidity: ≤ 85%
⑶ Power supply: AC(220±22)V; (50±0.5)Hz
⑷ No significant vibration or electromagnetic interference, avoid direct sunlight.

With strong scientific research capabilities and years of experience in water quality monitoring, Lianhua Company has independently designed and developed multiple product series. Including: COD analyzer, ammonia nitrogen analyzer, total phosphorus analyzer, total nitrogen analyzer, BOD5 analyzer, heavy metal analyzer, multi parameter water quality analyzer, water quality online monitoring instrument, etc. Which COD analyzer is good? Welcome to inquire by phone.
It is an indicator of the amount of reducing substances in water. The reducing substances in water include various organic compounds, sulfides, ferrous salts, etc. But the main thing is organic matter. Therefore, chemical oxygen demand (COD) is often used as an indicator to measure the content of organic matter in water. The higher the chemical oxygen demand, the more severe the pollution of organic matter in the water body. The determination of chemical oxygen demand (COD) varies depending on the reducing substances in the water sample and the measurement method used. The Jieyang COD analyzer also has different measurement values.
Functional features:
1. Time saving: The entire measurement process, including steps such as water sample digestion and colorimetric determination, requires less than 30 minutes. Which COD analyzer is stronger; The instrument comes with 20 standard curves that can be self adjusted and saved. 2. It has minimal secondary pollution to the environment: the reagent volume is one tenth of that of the reflux method, and the amount of waste liquid generated is extremely small; The instrument can automatically calculate and store 10 regression fitting curves. 3. Safe and reliable: the digestion device has anti spray protection, which can effectively prevent water sample overflow caused by insufficient acid concentration; Print current data and all stored historical data

With strong scientific research capabilities and years of experience in water quality monitoring, Lianhua Company has independently designed and developed multiple product series. Including: COD analyzer, ammonia nitrogen analyzer, total phosphorus analyzer, total nitrogen analyzer, BOD5 analyzer, heavy metal analyzer, multi parameter water quality analyzer, water quality online monitoring instrument, etc. Welcome to inquire by phone.
COD analyzer features:
The instrument has low requirements for the location and can adapt well to the following situations:
A single instrument can adapt to water quality monitoring at multiple sampling points. The instrument can be brought to the site for direct measurement, and the COD analyzer can be quoted. Samples from various locations can also be collected in the laboratory for centralized measurement.
B can quickly indicate the reaction status of intermediate processes in the process
Different levels of response will have corresponding characteristic absorption coefficients, and we can use the latter to quickly estimate the former. Of course, you must know the type of measurement object in advance before you can match it.
C can simultaneously deduct the influence of turbidity, and the sample does not need to be processed.

Which COD analyzer is strong? Jieyang COD analyzer. Lianhua Technology 123 (view) is provided by Guangzhou Lianhua Environmental Protection Technology Co., Ltd. Guangzhou Lianhua Environmental Protection Technology Co., Ltd. (www.gdlhkj. com) adheres to the corporate philosophy of "people-oriented", has a professional team of employees, strives to provide good products and services to give back to society, and welcomes new and old customers to visit and cooperate sincerely to create a better future. Lianhua Technology - your trusted friend, company address: Room 408, Taotaole E-commerce Building, No. 88 Tianmei Road, Yunshan Avenue, Xinhua Street, Huadu District, Guangzhou, contact person: Zeng Yanping.