Miaosu
Product features:
1. Product Usage: This product is suitable for power lines with a rated voltage (U0/U) of 3.6/6 to 26/35KV, for the purpose of power transmission and distribution.
2. Product standard: GB12706-91 rated voltage 35KV and below copper core, aluminum core plastic insulated power cables.
3. Product usage characteristics: (1) When laying cables in environments with temperatures not lower than 0 ℃, there is no need for pre heating. The laying height of cables is not limited. (2) The long-term allowable working temperature of the cable core shall not exceed the following regulations: for cables with an outer protective layer of polyvinyl chloride sheath, the temperature shall be 90 ℃; The outer protective layer of the cable is made of polyethylene sheath, and the temperature is 80 ℃. (3) When the wire core is short circuited (for a maximum of 5 seconds), the temperature shall not exceed 250 ℃. (4) The minimum bending radius for cable laying is specified as follows: single core cable: 20 (d+D) ± 5%; Three core cable: 15 (d+D) ± 5%. In the formula: D is the actual outer diameter of the cable, and d is the actual outer diameter of the conductor.
4. Product model, name, and scope of use
Model Name Scope of Use
Copper core and aluminum core
YJVYJLV cross-linked polyethylene insulated polyvinyl chloride sheathed power cables are fixed and laid in the air, indoors, cable trenches, tunnels, or underground
YJYJYLY cross-linked polyethylene insulated polyethylene sheathed power cables are fixed and laid indoors, in cable trenches, tunnels, or underground
YJV22YJLV22 cross-linked polyethylene insulated steel tape armored polyvinyl chloride sheathed power cable is fixed and laid in places with external pressure
YJV23YJLV23 cross-linked polyethylene insulated steel tape armored polyethylene sheathed power cable is fixed and laid in places where external forces are often applied
YJV32YJLV32 cross-linked polyethylene insulated fine steel wire armored polyvinyl chloride sheathed power cable is fixed and laid in places that require it to withstand tensile force
YJV33YJLV33 cross-linked polyethylene insulated fine steel wire armored polyethylene sheathed power cable is fixed and laid in places where it is required to withstand tensile force
YJV42JYLV42 Cross linked polyethylene insulated thick steel wire armored polyvinyl chloride sheathed power cable is fixed and laid underwater, in vertical shafts, or in places where tensile strength is required
YJV43YJLV43 Cross linked polyethylene insulated thick steel wire armored polyethylene sheathed power cable is fixed and laid in places that require it to withstand high tensile forces
Note: One or two single core cables are not allowed to be laid in iron pipes.
5. Production scope
Model number
Number of cores
Rated voltage U0/U KV
3.6/6 6/66/10 8.7/10-12/20 18/2021/35 26/35
Nominal cross-section of conductive wire core (mm2)
YJLV
YJV
YJLY
YJY125-50025-50035-50050-300
YJLV32
YJV32
YJLY32
JY32125-50025-50035-50050-300
YJLV42
YJV42
YJLV43
YJV43125-50025-50035-50050-300
YJLV
YJV
YJLY
YJY325-30025-30035-300-
YJLV22
YJV22
YJLV23
YJV23325-30025-30035-300-
YJLV32
YJV32
YJLV33
YJV33325-30025-30035-300-
YJLV42
YJV42
YJLV43
YJV43325-30025-30035-150