The XZB series variable frequency series resonance consists of a variable frequency power supply, excitation transformer, reactor, capacitive voltage divider, and compensation capacitor (optional). The capacitor and reactor of the test sample form a series resonant connection; The voltage divider is connected in parallel to the test sample to measure the resonant voltage on the test sample and provide an overvoltage protection signal; The frequency modulation power output is coupled to the series resonant circuit through an excitation transformer, providing excitation power for series resonance. The variable frequency series resonance test device applies the principle of series resonance, uses an excitation transformer to excite the series resonance circuit, adjusts the output frequency of the variable frequency controller, and causes the circuit inductance L and the test sample C to resonate in series. The resonance voltage is the voltage applied to the test sample. The frequency conversion resonance test device is widely used in industries such as power, metallurgy, petroleum, and chemical engineering, and is suitable for the handover and preventive testing of high-capacity, high-voltage capacitive specimens.
The complete set of frequency conversion series resonance test equipment is mainly designed for AC withstand voltage testing of cross-linked cables, hydroelectric generators, main transformers, busbars, GIS, etc. It has a wide range of applications and is an ideal withstand voltage equipment for high voltage testing departments and power installation and maintenance engineering units at the prefecture, city, and county levels.
Product nickname: AC voltage withstand resonance device, variable frequency resonance, variable frequency series resonance, series resonance, series resonance transformer, electrical equipment variable frequency series resonance voltage withstand device, series resonance test equipment, variable frequency series resonance test complete set device.
rated output voltage | 0-1000kV and below |
OUTPUT FREQUENCY | 20-310Hz |
Resonant voltage waveform | Pure sine wave, waveform distortion rate ≤ 1.0% |
working hours | Under rated load, continuous operation for 60 minutes is allowed; Overvoltage 1.1 times for 1 minute |
Quality factors | 30~90 |
Frequency regulation sensitivity | 0.1Hz |
Instability | <0.05% |
Input working power supply |
Single phase 220V or three-phase 380V ± 10% |
Power frequency 50Hz ± 5% | |
ambient temperature | -10℃~+50℃ |
relative humidity | ≤ 95%, no condensation condition |
altitude | ≤ 3000 meters |
Temperature rise | Temperature rise ≤ 65K after 60 minutes of continuous operation under rated load |
measurement accuracy | Effective value of the system at level 1.5 |
scope of application |
Cable frequency conversion resonant device |
Generator power frequency withstand voltage test device | |
AC voltage withstand test device for electrical equipment in substations | |
Resonant boost device for CVT inspection |
Series product configuration (applicable range (10kV~500kV voltage level substation electrical equipment AC withstand voltage equipment, frequency 30-300Hz)
Product model name | Variable frequency source | Resonant reactor | driver transformer | Voltage divider | fitScope of use |
XZB-75/75 | 4kW | Three units of 25kV/1A (dry-type) | 4kVA (dry type) | 80kV | 1000kVA and below 10kV power transformer. 10kV switch, busbar, PT, CT, etc. 10kV(300mm2)Cable ≤ 1.0km |
XZB-108/108 | 6kW | Four units of 27kV/1A (dry-type) | 6kVA (dry type) | 110kV | 31500kVA and below 35kV power transformers. 35kV switches, busbars, PT, CT, etc. 10kV(300mm2)Cable ≤ 2km. 35kV (300mm2)Cable ≤ 0.5km |
XZB-200/200 | 10kW | 50kV/1A four units (dry type) | 10kVA (dry type) | 200kV | 50000kVA and below 110kV power transformer. 110kV GIS, PT, CT, etc. (preventive testing). 35kV(300mm2)Cable ≤ 1.0km. 10kV (300mm2)Cable ≤ 2.0km |
XZB-270/270 | 15kW | Six units of 45kV/1A (dry-type) | 15kVA (dry type) | 300kV | 50000kVA and below 110kV power transformer. 110kV GIS, PT, CT, etc. 35kV(300mm2)Cable ≤ 1.2km. 10kV (300mm2)Cable ≤ 3.0km |
XZB-800/400 | 30kW | 50kV/2A eight units (dry type); 100kV/2A four units (oil immersed) | 30kVA (dry type); 30kVA (oil immersed) | 400kV | 80000kVA and below 220kV power transformers. 50000kVA and below 110kV power transformer. 110kV/220kV GIS, PT, CT, etc. 35kV(300mm2)Cable ≤ 2.0km. 110kV (300mm2)Cable ≤ 0.7km |
XZB-1600/800 | 60kW | 200kV/2A four units (oil immersed) | 60kVA (dry type) | 800kV | 80000kVA and below 220kV power transformers. 50000kVA and below 110kV power transformer. 500kV GIS, PT, CT, etc. 220kV switches, GIS, PT, CT, etc. 110kV(400mm2)Cable ≤ 1.5km. 220kV (400mm2)Cable ≤ 1.0km |
Note:1. The appearance of the product is subject to the actual product. Technical parameters and models are subject to change without prior notice. If there is any act of theft or copying, legal responsibility will be pursued
2. To learn more about Huayi products, please enter the product center. Service Hotline:
1. Cables with voltage levels of 35kV and below are widely used and require a large amount of testing work. Therefore, this type of voltage withstand test device is small in size and light in weight, giving rise to portable cable voltage withstand test systems;
2. This system requires that the weight of components that can be moved on-site by a single person should not exceed 30kg, and the weight of components that can be moved on-site by two people should not exceed 60kg, which is suitable for on-site handling;
3. The power supply adopts 220V single-phase power supply or 380V single power supply, which is convenient for on-site power supply. The reactor part adopts dry-type epoxy casting, which is beautiful and reliable, suitable for the requirements of various cables;
4. Oil immersed reactors are used for the withstand voltage test of cables with voltage levels of 110kV and above. When the individual weight exceeds 100kg, our company's dedicated small electric crane can be optionally equipped;
5. Simple operation, small size, light weight, very convenient for on-site use and handling (volume and weight are about 1/10 to 1/30 of traditional test transformers;
6. Unique low harmonic patented technology, with a measured harmonic content of less than 0.3% at Wuhan High School, far below the national standard requirement of no more than 5%, greatly protecting equipment such as main transformers and generators from high-voltage harmonic damage;
7. Verified by a third-party authority;
8. Compliant with national standards, it has peak monitoring function and can monitor high-voltage test waveforms in real time. It has low requirements for on-site power supply and good test equivalence;
9. Large LCD screen, "foolproof" and easy-to-use, with a built-in micro printer for printing and saving test data at any time;
10. Reactors of the same voltage level and capacity have smaller volume and lighter weight; Low temperature rise at rated load; Adopting dry casting, high mechanical strength, good electrical insulation performance, beautiful and reliable;
11. The variable frequency power supply control box has a large capacity margin; Strong protection function; Good output waveform; Good stability; Having multiple working modes and easy operation; Single phase 220V or three-phase 380V input power supply is universal, convenient for on-site power supply;
12. Flexible configuration. Different types of reactors can be selected to meet the requirements of different test samples, achieving multi-purpose and high cost-effectiveness;
Product Attachment Diagram
-
Variable frequency power supply
-
Voltage divider
-
High voltage reactor
-
driver transformer
Product detail diagram
-
Detail drawing
-
Detail drawing
-
Detail drawing
-
Detail drawing
-
Detail drawing
-
Detail drawing
-
Detail drawing
-
Detail drawing
-
Detail drawing
-
Detail drawing
-
Detail drawing
-
accessory kit
Product Process Diagram
-
Production drawing
-
Production drawing
-
Production drawing
-
Production drawing
-
Production drawing
-
Production drawing
-
Production drawing
-
Production drawing
-
Production drawing
-
Production drawing
-
Production drawing
-
Production drawing