characteristic:
● Three phase electric energy meter● Provide 6+1 clear LCD large character display
Accuracy Class 1
● Pulse output
Installation of 35mm guide rail
RS485 communication
Multi functional guide rail table:
PRODUCT MODEL | Measurement function | External dimensions | Dimension | Current/voltage specifications |
YN300 | Function: Three phase active/reactive positive/negative energy, three-phase voltage, current, active power, frequency, reactive power, power factor | 126*89 | DIN-Rail Mounting 35mm |
3×220/380V 3×1.5(6)A 3×5(20)A 3×10(40)A 3×20(80)A |
YN300-E | Function: Same as YN300, with additional RS485 communication | 126*89 | DIN-Rail Mounting 35mm |
3×220/380V 3×1.5(6)A 3×5(20)A 3×10(40)A 3×20(80)A |
YN300-E/FC | Function: Same as YN300-E, with additional multi rate, eight time periods and four types of multi rate: peak, off peak, off peak, and off peak, RS485 communication | 126*89 | DIN-Rail Mounting 35mm |
3×220/380V 3×1.5(6)A 3×5(20)A 3×10(40)A 3×20(80)A |
YN100 | Function: Single phase active/reactive positive/reverse phase electrical energy, voltage, current, active power, frequency, reactive power, power factor | 76*89 | DIN-Rail Mounting | 220V 1.5(6)A 5(20)A 10(40)A 20(80)A 50HZ/60HZ |
YN100-E | Function: Single phase active/reactive positive/negative energy, voltage, current, active power, frequency, reactive power, power factor, RS485 communication | 76*89 | DIN-Rail Mounting | 220V 1.5(6)A5(20)A 10(40)A20(80)A 50HZ/60HZ |
YN100-E/FC | Function: Same as YN100-E function, with additional multi rate, eight time periods and four types of multi rate: peak, off peak, off peak, and off peak, RS485 communication | 76*89 | DIN-Rail Mounting | 220V 1.5(6)A 5(20)A 10(40)A 20(80)A 50HZ/60HZ |
Overview:
Multi functional power meters are the new generation of miniature rail type energy meters developed by our company based on years of experience in meter design. This instrument adopts LCD display, which can set parameters such as clock, rate period, etc., and has the function of outputting electric energy pulses; RS485 communication interface can be used to exchange data with the upper computer, greatly facilitating the automation management of electricity consumption. This instrument has the advantages of small size, high accuracy, good reliability, and easy installation. Its performance indicators meet the technical requirements of international GB/T17215, GB/T17883, and DL/T614 for instruments in the power industry.Technical indicators:
project | index | |
YN100 | YN300 | |
accuracy class | Merit: Level 1 | |
Participate in voltage Un | single-phase: AC22V | Three phase: 3 × 220/380V |
Current specifications | 1.5 (6), 5 (20) A, 10 (40) A, 20 (80) A | |
measuring range | 45~55HZ | |
Working voltage range | Normal operating voltage: 0.7Un~1.2Un | |
operation temperature | Normal operating temperature:- 10℃~+70℃ | |
power consumption | Voltage circuit: ≤ 5VA | Voltage circuit: ≤ 5VA |
Current circuit: < 4VA/phase (at maximum current) | ||
Clock accuracy | ≤0.5S/D | |
Pulse output parameters | Pulse width: 80ms ± 20ms Passive output, pulse constant is 5000imp/kwh | |
Communication protocol | MODBUS-RTU (other customizable) | |
External dimensions | 76×89×74(mm) | 126×89×74(mm) |
YN300 Function:
meteringMeasure forward and reverse electrical energy, and have automatic recognition and indication of power direction.
The total, peak, off peak, flat, and valley electrical energy are stored separately and saved in the corresponding storage units.
The electricity meter can store data for three months, and the default frozen transfer date for electricity is 24:00 at the end of the month (frozen at the end of the month).
After power failure, all stored data will not be lost and can be maintained for more than 10 years.
Clock and Time Rate
The clock error is within 0.5S/day, and it has automatic switching functions for calendar, timing, and leap year.
Programmable settings for peak, off peak, off peak, and off peak rates, with 8 time slots available per day and a minimum interval of 1 hour between slots.
display
7-bit wide temperature LCD display.
It can display the effective values of voltage and current in real time, and can achieve data rotation display with a cycle display time of 4 seconds.
The electric energy pulse is indicated by a red LED.
The Chinese characters indicate peak, off peak, off peak, and off peak periods for the four middle school rates.
output
Active energy pulse output, used for meter calibration and energy collection.
communication
Used for parameter setting and meter reading.
RS485 communication interface, MODBUS-RTU communication protocol.
programming
Programming settings are performed through the upper computer.
Time and date settings.
Meter address setting.
Rate period setting.
Reset the battery level to zero.
Outline drawing and hole size drawing:

Wiring method:

Installation diagram:
The YN series rail mounted electric energy meter adopts a 35mm standard rail mounted installation method, as shown in the following figure:
Typical application diagram of YN300-E/FC:
YN300-E/FC is a three-phase multi rate active energy meter.YN300-E/FC has a pulse output that can collect the consumption of active electrical energy and achieve DCS remote transmission.
YN300-E/FC has RS485 communication function, which can achieve meter reading and programming settings through the upper computer.