Shandong Songyue Instrument Co., Ltd
Home>Products>YSC218 insoluble solid specific Karl Fischer moisture analyzer
Firm Information
  • Transaction Level
    VIP member
  • Contact
  • Phone
    1380533621618653303691
  • Address
    No.1 Xisan Lane, Liuquan Road, Zhangdian District, Zibo City, Shandong Province
Contact Now
YSC218 insoluble solid specific Karl Fischer moisture analyzer
1. The high-precision Coulomb method moisture analyzer is used in conjunction with a Kjeldahl heating furnace, which can detect a minimum of 3 μ g of
Product details

Product brief
The YSC218 insoluble solid specific Karl Fischer moisture analyzer fills the gap in China. It adopts a unique needle design, which can achieve both carrier gas input and water vapor output in one operation. At the same time, due to the new gas path design, water vapor transmission can be achieved with extremely low flow rate. Each injection only requires changing the sample bottle for easy operation, without waiting for the sample bottle to cool down before changing the bottle cap. The detection accuracy can reach ppm level, which is very suitable for industries such as lithium batteries, plastic particles, and petrochemicals that have high requirements for moisture detection.


1. The high-precision Coulomb method moisture analyzer is used in conjunction with a Kjeldahl heating furnace, which can detect a minimum of 3 μ g of water with an accuracy of ppm level;

Two hollow core gas injection needles and gas delivery pipelines with heating function, zero dead volume water vapor does not condense, making operation simpler and greatly improving the accuracy and repeatability of the instrument;

3 high-definition capacitive touch screen, implementing display measurement parameters, concise and clear functional menu, comprehensive parameter display, easy and fast operation;

4 built-in 5 methods to choose from, 8 calculation formulas for convenient sample testing, custom sample units such as%, ppm, mg/kg, etc. result units are more user-friendly;

The 5 system detects moisture in the environment in real-time, accurately deducts drift, and uses real-time dynamic impedance method to determine the titration endpoint, resulting in more accurate measurement results;

The maximum temperature of 300 ℃ can meet the testing requirements of most samples, and the airflow can be adjusted from 0-100ml, suitable for samples with various water release rates;

Easy to operate, users only need to set the appropriate temperature and flow rate, put the sample into the pre prepared sample bottle, put it into the heater, then insert the transfer needle into the silicone pad of the sample bottle, and click on the instrument to start measuring.

8. There is no need to wait for the previous sample bottle to cool down before proceeding to the next sample measurement. During the process of replacing the sample bottle, the sample bottle always remains sealed, resulting in higher and more accurate measurement efficiency. Especially for samples with strong moisture absorption, there is no need to worry about the interference of moisture in the air.

9. Use headspace injection method to ensure that each measurement is conducted usingThe "new" sample bottle has no cross infection detected during sample testing. The sample bottle has a small volume, ensuring a small dead volume and background moisture value. The independent sealed sample bottle does not require sample transfer during measurement, resulting in more accurate results. The screw cap sample bottle does not require specialized and expensive capping and opening devices, making it very convenient to use.

10 headspace sampling technology, only gas enters the reaction cup of the moisture analyzer, without contaminating the reaction cup and electrolytic electrode;

Product application:

Lithium battery material:Moisture detection of lithium battery materials such as lithium cobalt oxide, lithium nickel oxide, carbon composite lithium iron phosphate positive electrode materials for lithium-ion batteries, lithium titanium oxide and its composite negative electrode materials for lithium-ion batteries, nano lithium iron phosphate, lithium manganese oxide, nickel cobalt manganese oxide, lithium titanium oxide, lithium iron phosphate, lithium nickel cobalt aluminum oxide, nickel cobalt aluminum ternary composite hydroxide, lithium hexafluorophosphate, lithium hexafluorophosphate, lithium hexafluorophosphate electrolyte, graphite negative electrode materials, lithium battery membranes, and electrode sheets.

Plastic particles and plastic products:High density polyethylene (HDPE), polyethylene (PE), low-density polyethylene (LDPE), polypropylene (PP), oriented polypropylene (OPP), polyvinyl chloride (PVC))Polyethylene, cross-linked polyethylene, polyvinyl chloride, polypropylene, polyolefin, fluoroplastic, nylon(PPA)Medical sutures (polypropylene), disposable medical supplies (polyvinyl chloride, low-density polyethylene, resin, etc.)POE and other materials

Other substances that are insoluble or have side reactions with Karl Fischer reagent:Ore, carbonate and metal oxides, carbon powder, petrochemical products containing additives (engine oil, lubricating oil and grease), raw materials for pharmaceuticals, freeze-dried powder samples, leather, sealants, etc.





1. Measurement range: 3 μ g to 19999.9 μ g of water

2. Measurement speed: 2.24mg H2O/min (maximum)

3. Temperature control accuracy: 1 ℃

4. Measurement accuracy: 3 μ g (10ug-100 μ g H2O) ≤ 0.3% (water content>100 μ g H2O)

5. Resolution: 0.1 μ g H2O

6. Delay titration: 0-9999 seconds

7. Sample methods: 5 independent methods

8. Calculation formula:built-in8 calculation formulas

9. Temperature control range:room temperature-300℃

10. Heating rate: 30 ℃/min (50-180 ℃, 220V)

11. Flow range: 0-100ml/min

12. Sample bottle size: 10ml (5ml, 20ml optional)

13. Data printing: built-in thermal printer