The Zhong'an S105 gas detector adopts a hybrid technology of two-wire signal and power supply. Only 2 wires are needed for wiring, and it is convenient to connect without positive and negative poles. The detector integrates sound and light display, and can be wirelessly controlled to debug parameters. It can also display and monitor the gas concentration on site in real time, without the need to open the cover. It is safe and simple.
The Zhong'an S105 point type gas detector can convert the concentration signal of leaked gas in the air into an electrical signal for remote transmission. The instrument has the advantages of long transmission distance, anti-interference, high sensitivity, and fast response time.
Product features:
◆ Simple non-polar wiring and no short circuit design
◆ Two bus structure wiring saves time, effort, and cost
◆ Integrated sound and light alarm
◆ High measurement accuracy and small zero drift
Explosion proof design can be used in hazardous areas 1 and 2 under factory conditions
Wireless remote control technology
◆ Intuitive digital display
Two sets of switch signals
Technical Parameter
Detect gas |
Combustible/toxic and harmful gases (see attached table) |
detection |
Natural diffusion |
Detection Principle |
catalysis; electrochemistry; semiconductor; Infrared radiation; laser |
detection range |
(0~100%)LEL; 0-****PPM |
Resolution |
1%LEL; 1PPM/0.1PPM |
Display |
LED display |
debug mode |
Controller |
Battery |
DC24V |
output signal |
two-wire system |
Power consumption |
≤3W |
Alarm |
Sound and light alarm |
response time |
Flammable:< 15s; Toxicity:< 60s |
Working environment |
Temperature: -20 ℃ -60 ℃; Humidity:< 95%RH |
Explosion proof grade |
Exd IIC T6 Gb |
protection grade |
IP66 |
Instrument size |
(182×175×73)mm |
Instrument weight |
1500g |
product accessories
Product images
Tested gas |
measuring range |
Optional range |
resolution |
response time |
Flammable EX |
0-100%LEL |
0-100% VOL (infrared) |
1%LEL/1%VOL |
≤ 15 seconds |
Oxygen O2 |
0-30%VOL |
0-30%, 0-100% VOL |
0.1%/0.01%VOL |
≤ 15 seconds |
Hydrogen sulfide H2S |
0-100PPM |
0-50, 200, 1000PPM |
0.1/1PPM |
≤ 15 seconds |
Carbon monoxide CO |
0-1000PPM |
0-500/2000/5000PPM |
0.1/1PPM |
≤ 15 seconds |
Nitrogen dioxide NO2 |
0-20PPM |
0-50, 1000PPM |
0.1/1PPM |
≤ 20 seconds |
natural gas |
0-100%LEL |
0-100%VOL |
1%LEL/1%VOL |
≤ 15 seconds |
Nitrogen oxides |
0-20PPM |
0-50, 1000PPM |
0.1/1PPM |
≤ 20 seconds |
methane |
0-100%LEL |
0-100%VOL |
1%LEL/1%VOL |
≤ 15 seconds |
Carbon dioxide CO2 |
0-5000PPM |
0-1%, 5%, 10% VOL (infrared) |
1PPM/0.01%VOL |
≤ 20 seconds |
Nitric oxide NO |
0-250PPM |
0-500, 1000PPM |
1PPM |
≤ 20 seconds |
nitrogen |
0-100%VOL |
0-100%VOL |
0.1%VOL |
≤ 15 seconds |
alcohol |
0-100%LEL |
0-100%LEL |
1%LEL/1%VOL |
≤ 15 seconds |
Sulfur dioxide SO2 |
0-20PPM |
0-50, 1000PPM |
0.1/1PPM |
≤ 20 seconds |
Chlorine gas CL2 |
0-20PPM |
0-10, 50, 100PPM |
0.1PPM |
≤ 20 seconds |
dichlorosilane |
0-20PPM |
0-20, 100PPM |
1/0.1PPM |
≤ 20 seconds |
Ammonia NH3 |
0-100PPM |
0-50, 500, 1000PPM |
0.1/1PPM |
≤ 20 seconds |
SILICON TETRACHLORIDE |
0-20PPM |
0-20, 100PPM |
1/0.1PPM |
≤ 20 seconds |
Hydrogen H2 |
0-1000PPM |
0-40000PPM |
1/10PPM |
≤ 20 seconds |
Phosphine PH3 |
0-20PPM |
0-20, 1000PPM |
0.1/1PPM |
≤ 20 seconds |
Hydrogen chloride HCL |
0-20PPM |
0-20, 50, 100PPM |
0.1/1PPM |
≤ 20 seconds |
acrylonitrile |
0-100PPM |
0-100PPM |
1PPM |
≤ 20 seconds |
TVOC |
0-100PPM |
0-100PPM |
1PPM |
≤ 20 seconds |
CLO2 |
0-50PPM |
0-10, 100PPM |
0.1PPM |
≤ 20 seconds |
Hydrogen cyanide HCN |
0-50PPM |
0-100PPM |
0.1PPM |
≤ 20 seconds |
Ethylene oxide ETO |
0-10PPM |
0-100, 1000PPM |
1PPM |
≤ 20 seconds |
Ozone O3 |
0-10PPM |
0-20, 100PPM |
0.01/0.1PPM |
≤ 20 seconds |
Formaldehyde CH2O |
0-20PPM |
0-50, 100PPM |
0.1/1PPM |
≤ 20 seconds |
Fluorine gas F2 |
0-10PPM |
0-1, 10PPM |
1/0.1PPM |
≤ 20 seconds |
Hydrogen fluoride HF |
0-10PPM |
0-1, 10, 50, 100PPM |
0.01/0.1PPM |
≤ 20 seconds |
Xylene, toluene |
0-20PPM |
50, 100PPM |
0.1/1PPM |
≤ 20 seconds |
stench |
0-100PPM |
0-100PPM |
1PPM |
≤ 20 seconds |
For gases not listed, please contact our sales department |