Magnetic flip column level gaugeIt is a device specially developed for liquid level measurement based on the principles of magnetism, Archimedes' law of buoyancy, and the characteristics of mechanical transmission; Among them, ZY-F2 type is the most basic product, and all other products are extensions based on it; We endow them with more practical functions while detecting liquid levels. Before you choose this product, we will firstMagnetic flip column level gaugeProvide a brief introduction to the working principle of. It has a cavity that accommodates a floating ball, which we call the main tube or shell. It forms a connector with the container through a flange or other interface; In this way, the liquid level inside the chamber is at the same height as the liquid level inside the container, so the floating ball inside the chamber will rise and fall with the rise and fall of the liquid level inside the container; At this point, we cannot see the liquid level, so we installed a flip column display outside the chamber. When manufacturing the float, we installed magnetic steel at the junction of the float sinking into the liquid and the floating part. When the float rises and falls with the liquid level, its magnetism is transmitted through the shell to the flip column display, pushing the magnetic flip column to flip 180 degrees; Due to the fact that the magnetic flip column is a cylindrical body composed of two semi cylinders, red and white, the color of the display facing outside the flip column after flipping 180 ° will change (red below the liquid level and white above), and the height of the liquid level is at the junction of the two colors. The control type is based on the flip column level gauge and adds a magnetic switch. While monitoring the liquid level, the magnetic switch signal can be used to control or alarm the liquid level; The remote transmission type is based on the flip column level gauge and adds a 4-20mA transmission sensor. While monitoring the liquid level on site, the changes in the liquid level are transmitted to the control room through transmission sensors, cables, and instruments, achieving remote monitoring and control.
key word:
|
Liquid level measurement and control, interface measurement and control
|
Measurement range [L]: (Center distance between upper and lower flanges)
|
User proposed
|
Connection flange specifications:
|
DN20 PN1.0RF or requested by the user
|
Liquid receiving material: 321 or 304 stainless steel 316l stainless steel pvc plastic Stainless steel lined with PTFE
|
321 or 304 stainless steel Or user specified
|
Medium density [g/cm3]: (Proposed by the user)
|
≥0.53
|
Working temperature [℃]:
|
≤80℃,≤ 150℃,≤ 350℃
|
Work pressure [MPa]:
|
0~4.0MPa
|
Output signal:
|
Upper and lower limits or multiple points (divided into point type or bidirectional holding type)
|
Applicable voltage/current:
|
≤250VA(D)C/500mA
|
|