1、 Process flow of 15 ton/hour reverse osmosis water treatment equipment: raw water pump - quartz sand filter - activated carbon filter - fully automa
Product details

115ton/The process flow of hourly reverse osmosis water treatment equipment:
Raw water pump - quartz sand filter - activated carbon filter - fully automatic water softener - security filter - reverse osmosis main pump - reverse osmosis pure water device - pure water tank - water point

II15ton/System parameters of hourly reverse osmosis water treatment equipment:

Raw water: tap water, well water, groundwater, reclaimed water;
Inlet pressure: 0.2~0.3MPa;
Operating pressure: 0.3~1.5MPa;
Desalination rate:> 99%
Water production capacity: 15T/H (can be determined according to customer needs);
Conductivity of water production: < 10μs/cm;
Control: Fully automatic control/integrated manual and automatic switching;
Material: Stainless steel 304;
Process: Reverse osmosis membrane separation technology.

Application industries: pharmaceuticals, vitamin E production, eyewear production, cleaning of medical devices, food, beverages, jelly, direct drinks, alcoholic beverages, etc. Manufacturers with high requirements can use them as raw materials, solutions, or cleaning containers;

III15ton/Pre treatment system for hourly reverse osmosis water treatment equipment
Preprocessing aspurified waterThe reliance on production is very important because reverse osmosis requires water inflow, and improving pre-treatment facilities as much as possible can effectively prolong the processreverse osmosis membraneThe cleaning cycle or service life, components and functions of the pre-treatment system are as follows:
1. Raw water pump
The raw water pump is used to provide raw water pressure for the raw water pretreatment system, and generally requires a raw water pressure of>=0.3MPa
2. Raw water tank
Raw water tankThe function is simpler, it is to store raw water as a buffer for subsequent equipment, avoiding problems such as emergency shutdown due to water shortage, unstable water pressure causing damage to the water pump, etc. (usually adding a float switch to increase the automation level of the entire system).
3. Quartz sand filter
useQuartz sandFilter media is used to remove suspended solids, sediment, impurities, and other larger particles from raw water, reducing water turbidity. It can also effectively remove organic matter, bacteria, viruses, and other pollutants from the water as turbidity decreases.
4. Activated carbon filter
Effectively utilizing the adsorption capacity of activated carbon to adsorb organic matter, free residual chlorine, colloids, particles, microorganisms, certain metal ions, and decolorization in raw water.
5. Softening system (dosing system)
utilizeion exchange resinThe exchange performance is improved to remove calcium and magnesium ions from the raw water, in order to prevent the impact of subsequent equipment scaling. Nowadays, many large equipment use dosing systems to directly add scale inhibitors to them.

5. Security filter

Retain residual impurities from the front-end filter to prevent direct fouling of the reverse osmosis membrane.

415ton/Shutdown protection measures for hourly reverse osmosis water treatment equipment:

a) Clean the membrane components in the system.

b) Prepare disinfectant solution using reverse osmosis produced water and rinse with disinfectant solutioncounter-infiltration system.

c) After filling the reverse osmosis system with disinfectant, close the relevant valves to keep the disinfectant in the system. At this point, confirm that the system is full.

d) If the system temperature is below 27 ℃, the first two steps should be performed with a new sterilizing solution every 30 days. If the system temperature is above 27 ℃, the protective solution (sterilizing solution) should be replaced every 15 days.

e) Before the reverse osmosis system is put back into use, rinse the system with low-pressure water for 1 hour, and then rinse the system with high-pressure water for 5-10 minutes. Whether it is low-pressure or high-pressure flushing, all the water discharge valves of the system should be opened. Before restoring the system to normal operation, it should be checked and confirmed that there is no disinfectant in the product water.

Produced by Green Health Water Treatment CompanyRO reverse osmosis equipmentIt has a high permeability and desalination rate, and has a high interception and removal effect on organic matter, colloids, particles, bacteria, etc. The entire separation process of RO reverse osmosis equipment has no phase change and reliable stability. Green Health Water Treatment Manufacturer has a professional technical team. With years of effort and development, we are dedicated to serving our customers with complete equipment, installation, commissioning, and after-sales service.