Tengzhou Zhongke Spectral Analysis Instrument Co., Ltd
Home>Products>2,5-dicresol analysis gas chromatograph
Product Groups
Firm Information
  • Transaction Level
    VIP member
  • Contact
  • Phone
    18663278921
  • Address
    No. 20, Xibeitan, Tengzhou City, Shandong Province
Contact Now
2,5-dicresol analysis gas chromatograph
Product Introduction: The 2,5-dicresol analysis gas chromatograph uses a BCD quartz capillary column as the chromatographic column, FID is a detector
Product details
brand ZKP/Zhongkepu

2,5-dicresol analysis gas chromatographMethod principle:2,5-dicresol is an important pharmaceutical and dye intermediate, and is the main raw material for the preparation of the new lipid-lowering drug gefitolozil. There have been no reports on its analytical methods, only a brief introduction to the spectra of phenolic substances in the literature. This article uses BCD quartz capillary column as the chromatographic column, FID is a detector that achieves faster and better separation through programmed heating, thereby improving analysis accuracy, shortening analysis time, and meeting the analysis requirements of industrial products.

Classic gas chromatography analysis spectrum

2,5-dicresol analysis gas chromatographoperation condition

Column temperature: initial temperature of 120 ℃, retention time of 19 min, final temperature of 220 ℃, retention time of 20 min, heating rate of 30 ℃/min; The temperature in the vaporization chamber is 250 ℃; Detector (FID) temperature 200 ℃, carrier gas (N2): 0.125 MPa, Separation ratio of 100:1, tail blowing 0 07 MPa; Injection volume: 0.1 LL.

Equipment configuration and reagents

product name

configuration

quantity

gas chromatograph

GC-2020Equipped with (hydrogen flame detector+capillary injection port)

1tower

data processing

Chromatography workstation

1cover

chromatographic column

capillary column long30m*inside diameter0.25mm

1only

External air source

Nitrogen hydrogen air cylinder or generator

1cover

computer

Brand computer XP system

1tower

GC-2020 gas chromatograph(Determination of 2,5-dicresol contentPerformance characteristics

1. Adopting320 x 240dot matrix5.7An inch large screen LCD Chinese display, real-time display of various temperatures and operating conditions, clear and intuitive content, truly realizing human-machine dialogue;
2Power on self-test, wide range self diagnostic function, can accurately determine the fault location and alarm;
3Six independent temperature controls (vaporization chamber and capillary vaporization chamber can be independently controlled), Five level program heating function;
4Overtemperature Protection function: If any circuit exceeds the set temperature, the instrument will automatically power off and sound an alarm;
5The vertical heating device of * makes sample vaporization more reliable, reduces the heat radiation generated in the vaporization chamber to the minimum, and ensures minimal temperature deviation inside the column box;
6Intelligent fuzzy control rear door opening system, automatically tracks temperature and dynamically adjusts The angle of the air door can achieve precise temperature control even near room temperature;
7Configure filling column head injection, glass lining injection, with diaphragm cleaning Functional capillary diversion/Non split injection device and capable of installing gas injectors;
8High precision dual stable gas path, capable of installing four types of detectors simultaneously;
9
Optional electronic flow pressure display system with built-in workstation device.

Temperature control indicators
1.Temperature control range: room temperature
5400increment0.1
2.Temperature control accuracy: superior to±
0.01

Program heating: Five step interval constant temperature time0999minincrement0.1minTemperature increment0.1
Heating rate:
200The biggest one below40/min200Up to the biggest20/min

Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!