Shandong Zeshi Vacuum Equipment Co., Ltd
Home>Products>2SK series water ring vacuum pump and compressor
2SK series water ring vacuum pump and compressor
The 2SK series two-stage water ring vacuum pump and the 2SK-P1 series two-stage water ring vacuum pump atmospheric jet pump unit are used to extract a
Product details

The 2SK series two-stage water ring vacuum pump and the 2SK-P1 series two-stage water ring vacuum pump atmospheric jet pump unit are used to extract air and other non corrosive, water-insoluble, and solid particle free gases to achieve higher vacuum in closed containers.
It is widely used in vacuum evaporation, vacuum concentration, vacuum rehydration, vacuum impregnation, vacuum drying, and vacuum smelting in the fields of food, weaving chemicals, pharmaceuticals, metallurgy, and electronics. It has the characteristics of high vacuum degree, high pumping speed in high vacuum zone, compact structure, reliable operation, and easy maintenance.
The 2SK series is suitable for working conditions where the suction pressure is below -0.08MPa. The 2SK-P1 series is suitable for working conditions where the suction pressure is below -0.096MPa. When equipped with an atmospheric pump, the ultimate vacuum degree can reach -750mmHg.
The working vacuum range is -0.03-0.08MPa.

Main features:

  • Compared to single-stage water ring vacuum pumps, it has the characteristics of high vacuum degree and high pumping speed in high vacuum areas;
  • Compact structure and easy maintenance;
  • Widely applicable, it can extract various gases containing water vapor, flammable, explosive, small amounts of dust, and small amounts of liquid;
  • Mainly using water as the working medium, with low maintenance costs;
  • Can work in harsh environments.
  • Technical specifications for 2SK series two-stage water ring vacuum pump
    model
    swept volume
    (Mi)3/Score)
    mbar
    (MPa)
    (millimeters of mercury)
    power
    (Kilowatts)
    pump speed
    (Conversion/minute)
    water supply
    (L/min)
    caliber
    (mm)
    Pump weight
    (including motor)
    (Kg)
    maximum
    The suction pressure is
    -0.093MPa
    (-700mmHg)
    advance
    go out
    2SK-1.5
    1.5
    0.9
    -0.097(-725)
    4
    1440
    10-15
    40
    40
    140
    2SK-3
    3
    2
    -0.097(-725)
    7.5
    1440
    15-20
    40
    40
    180
    2SK-6
    6
    4
    -0.098(-735)
    15
    1460
    25-35
    50
    50
    250
    2SK-12
    12
    8
    -0.098(-735)
    22
    970
    40-50
    100
    100
    400
    2SK-20
    20
    14
    -0.098(-735)
    45
    740
    60-80
    125
    125
    550
    2SK-30
    30
    20
    -0.098(-735)
    55
    741
    60-80
    125
    125
    700
    Technical specifications for 2SK-P1 series two-stage water ring vacuum pump atmospheric jet pump unit
    model
    swept volume
    (Mi)3/Score)
    mbar
    (MPa)
    (millimeters of mercury)
    power
    (Kilowatts)
    pump speed
    (Conversion/minute)
    water supply
    (L/min)
    caliber
    (mm)
    Pump weight
    (including motor)
    (Kg)
    maximum
    The suction pressure is
    -0.093MPa
    (-700mmHg)
    advance
    go out
    2SK-1.5P1
    1.5
    0.9
    -0.099(-750)
    4
    1440
    10-15
    40
    40
    140
    2SK-3P1
    3
    2
    -0.099(-750)
    7.5
    1440
    15-20
    40
    40
    180
    2SK-6P1
    6
    4
    -0.099(-750)
    15
    1460
    25-35
    50
    50
    250
    2SK-12P1
    12
    8
    -0.099(-750)
    22
    970
    40-50
    100
    100
    400
    2SK-20P1
    20
    14
    -0.099(-750)
    45
    740
    60-80
    125
    125
    550
    2SK-30P1
    30
    20
    -0.099(-750)
    55
    741
    60-80
    125
    125
    700
    Note: 1. The performance indicators listed in the table refer to the performance indicators under the following specified conditions:
    ① The atmospheric pressure is 0.1013MPa (760mmHg)
    ② Inlet water temperature 15 ℃
    ③ Inhalation air temperature 20 ℃
    ④ Relative air temperature 70%
    2. The water supply is the value at a suction pressure of -0.05MPa (-400mmHg), and can be greater than this value at ultimate vacuum.
    3. Performance tolerance ± 10%
    4. When the suction pressure is -0.093MPa, the amount of air extracted is the amount of air extracted when using an electromagnetic valve to control the atmospheric pump.
code
A
A’
B
B’
C
D
D’
E
F
G
H
I
J
K
L
2SK-1.5P1
605
/
360
360
950
410
410
1150
422
485
270
30
125
214
162
2SK-3P1
710
/
400
400
1136
460
460
1346
417
491
265
35
159
214
157
2SK-6P1
863
/
420
420
1391
470
470
1623
500
608
315
30
218
234
183
2SK-12P1
1038
/
520
460
1642
580
520
1965
615
750
375
30
216
246
183
2SK-20P1
700
700
690
/
1972
750
/
2306
840
1004
500
30
306
283
225
2SK-30P1
810
750
720
/
2215
780
/
2715
840
1004
500
30
344
283
225
code
M
N
P
S
T
Z
n1
n2
d1
d2
d3
d4
d5
d6
d7
2SK-1.5P1
264
162
99
180
360
G1/2'
4
4
14
92
120
18
110
150
14
2SK-3P1
344
162
99
357
570
G1/2'
4
4
18
120
152
18
110
150
14
2SK-6P1
429
210
99
515
734
G1/2'
4
4
18
120
152
18
125
160
18
2SK-12P1
599
280
120
565
800
G1/2'
6
6
14
150
180
14
170
200
27
2SK-20P1
619
350
180
774
1022
G3/4'
8
8
18
200
235
18
200
235
27
2Sk-30P1
749
350
180
1016
1264
G3/4'
8
8
18
200
235
18
200
235
27

Two stage water ring vacuum pump and one stage large air pump pumping speed curve

Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!