301 two-wire HART intelligent temperature transmitter
The temperature at the industrial site is input to the 301X through a thermistor or thermocouple sensor, and after analog-to-digital conversion, it is
Product details

Technical Parameter

input
sensor type
301A/B1: Pt100,Pt1000,Cu50,Cu100
301A/B2: S,R,B,K,N,E,J,T,WRe3-25
301A/B3: Pt100,Pt1000,Cu50,Cu100
S,R,B,K,N,E,J,T,WRe3-25
Accept user specifications
Connection method
301A/B1: A two, three, or four wire heating resistance sensor
301A/B2: One thermocouple sensor and one thermistor sensor (three wire) are used for cold junction compensation, or a fixed cold junction temperature can be set for compensation without a thermistor sensor. The built-in thermistor sensor of the transmitter can also be used for cold junction compensation (the compensation accuracy will affect the final measurement accuracy)
301A/B3: Adopt the connection method of 301A/B1 or 301A/B2 according to the requirements
response time
≤ 250ms with sensor for short circuit and open circuit monitoring
output
Two wire system 4-20mA
HART
Load resistance Ra
Ra ≤ (Us-14.7V)/0.024A, Us is the loop voltage
sensor fault
Short circuit: Accept user specified (3.53.75mA)
Open circuit: Accept user specified (21)23mA)
system failure
Can be set to 3.2mA or 24mA
measurement accuracy
Accuracy (digital measurement accuracy)
See Appendix 1: List of Input Sensor Types and Accuracy
Analog output accuracy
0.025% full scale
Long-term Drift
The first year is less than 0.2% of full scale
Temperature influence
See Appendix 2: Effects of Environmental Temperature
rated operation conditions
ambient temperature
-4085℃ -2060 ℃ (explosion-proof type)
condensation
allow
electromagnetic compatibility
GB/T 17626, three-level
Protection level according to EN 60529
IP67
design
casing
Aluminum die-casting parts
weight
1kg (excluding temperature sensor)
size
See Appendix 3: Dimensional Drawing of Two Wire Intelligent Temperature Transmitter
Cable sealing pipe connection thread
M20 × 1.5 Other threads require adapter
Sensor connection
Integrated
split type
Display and Control
Display Size
33×23mm
Display digits
5 people
Unit (switchable)
℃ or ℉
set an option
Three buttons on the panel or a HART handheld device and configuration software compatible with the HART protocol
power supply
1536V DC
Electrical isolation
Ueff=1 kV, 50 Hz, 1 min between input and output
Certificates and approvals
Explosion proof type
ExdⅡCT6
Intrinsically safe type
ExiaⅡCT6

Two wire transmitters based on current loop power supply can effectively reduce wiring costs, lower power consumption, and improve anti-interference capabilities

• HART communication protocol
4-20mA output
When connected to a thermistor sensor, it has short-circuit and open circuit monitoring functions, and when connected to a thermocouple sensor, it has open circuit monitoring functions.
By using the built-in 3 operation buttons in conjunction with a high brightness LCD display, it is easy to set transmitter parameters locally. In addition, remote parameter configuration of the transmitter can be easily achieved through a HART modem.
The rotatable LCD display enhances the flexibility of transmitter installation and can display real-time information such as the percentage of the current measurement to full scale, the current measurement value and its unit, as well as sensor type and transmitter diagnostic information.
The enclosure has a protection level of IP67 and is suitable for outdoor applications
• Supports all sensors that comply with IEC751 and IEC584