Maintenance and upkeep:
1. The electric pump should be managed and used by a dedicated person, and the insulation resistance between the pump winding and the casing should be checked regularly to ensure that it is normal.
2. After each use, especially for thick and viscous slurries, the electric pump should be placed in clean water and run for a few minutes to prevent sediment from leaving inside the pump and ensure electricity
Cleaning of the pump.
3. If the electric pump is not used for a long time, it should be removed from the water and not soaked in water for a long time to reduce the chance of moisture in the motor stator winding and increase the service life of the electric pump^
4. Under normal conditions, the pump should be filled or replaced with engine oil (No. 10-30) in the oil chamber every 300-500 hours of use to maintain good lubrication of the mechanical seal
Sliding state improves the service life of mechanical seals.
After disassembling and repairing the electric pump, the casing components must undergo a 0.2MPa air tightness test to ensure reliable motor sealing.
The sealing ring between the impeller and the pump body has a sealing function. If the seal is damaged, it will directly affect the performance of the pump and should be replaced if necessary.
304 stainless steel unobstructed diving QW WQ model meaning:
Structural diagram of QW WQ non clogging submersible sewage pump made of 304 stainless steel:
304 stainless steel non clogging submersible sewage pump QW WQ product introduction:
QW (WQ) series unobstructed divingSewage pumpOn the basis of introducing advanced technology from the Federal German ABS pump company in the 1980s, and with the joint efforts of our research personnel, we have also extensively solicited domestic resourceswater pumpAccording to expert opinions, the product has been successfully developed through multiple improvements, and its performance indicators have reached the advanced level of similar foreign products after testing. This sewage pump is efficient and energy-saving, with a novel structure. diveSewage pumpAfter being launched on the market, it has been well received and praised by a large number of users for its unique efficacy and reliable quality. No blockageSubmersible pumpSelected by many units as a substitute for imported products and listed as a key project for introduction and digestion by the National Machinery Commission.
304 stainless steel non clogging submersible sewage pump QW WQ installation method:
304 stainless steel unobstructed submersible sewage pump QW WQ precautions:
1. Before using the pump, carefully inspect whether the cables are damaged, whether the fasteners are loose or detached, and whether the pump is deformed or damaged during transportation, storage, and installation.
2. Use a 500V megohmmeter to measure the insulation resistance between the same and relative ground of the electric pump motor. The value should not be less than 2 megohms. Otherwise, the motor stator winding should be dried at a temperature not exceeding 120 ℃.
The installation of this series of pumps comes in two types: fixed and mobile. When using fixed automatic installation, the chain cable should be threaded into two lifting ring screws or lifting plates (offset from the pump outlet, and its connection should be parallel to the pump outlet) to lift the electric pump up and down. Slowly and evenly slide down along the guide rail until it automatically couples into place. When using mobile installation, first cover the hose and thread the chain rope into two lifting rings to lift the electric pump up and down. Be careful not to use the cable as a rope to avoid danger.
4. The rotation direction of the pump after connection is counterclockwise when viewed from the inlet. If the electric pump is reversed, simply swap any two wires in the cable to adjust the wiring position.
5. The grounding wire of the casing of the electric pump must be strictly connected in accordance with relevant regulations. In order to ensure personal safety during use, it is strictly prohibited to install it nearby or let people go into the water for work while the electric pump is running~ Or move, just in case the electric pump leaks and accidents occur.
6. Unless there are special circumstances, the electric pump must be equipped with a fully automatic water pump control cabinet. Do not directly connect to the power grid or use a knife switch to connect the power supply to ensure the normal operation of the electric pump.
7. Do not operate the electric pump in a low head state for a long time (generally, the head should not be less than 60% of the rated head). It is best to control it within the recommended head range to prevent the electric pump from burning out the motor due to overload.
8. Pumps without self circulating cooling devices are strictly prohibited from being exposed to the water surface for long-term operation to prevent overheating and damage to the electric pump.
Maintenance and upkeep of 304 stainless steel non clogging submersible sewage pump QW WQ:
1. The electric pump should be managed and used by a dedicated person, and the insulation resistance between the pump winding and the casing should be checked regularly to ensure that it is normal.
2. After each use, especially for thick and viscous slurries, the electric pump should be placed in clean water and run for a few minutes to prevent sediment from leaving inside the pump and ensure electricity
Cleaning of the pump.
3. If the electric pump is not used for a long time, it should be removed from the water and not soaked in water for a long time to reduce the chance of moisture in the motor stator winding and increase the service life of the electric pump^
4. Under normal conditions, the pump should be filled or replaced with engine oil (No. 10-30) in the oil chamber every 300-500 hours of use to maintain good lubrication of the mechanical seal
Sliding state improves the service life of mechanical seals.
After disassembling and repairing the electric pump, the casing components must undergo a 0.2MPa air tightness test to ensure reliable motor sealing.
The sealing ring between the impeller and the pump body has a sealing function. If the seal is damaged, it will directly affect the performance of the pump and should be replaced if necessary.
304 stainless steel non clogging submersible sewage pump QW WQ performance parameters:
model |
caliber |
internet traffic |
lift |
rotational speed |
power |
efficiency |
A |
B |
C |
D |
H |
automatic coupler |
mm |
(m3/h) |
(M) |
(r/min) |
(kw) |
(%) |
|||||||
25-7-8-0.55 |
25 |
7 |
8 |
2900 |
0.55 |
45 |
120 |
360 |
225 |
210 |
540 |
|
25-8-22-1.1 |
25 |
8 |
22 |
2900 |
1.1 |
45 |
120 |
360 |
225 |
210 |
540 |
|
32-8-12-0.75 |
32 |
8 |
12 |
2900 |
0.75 |
48 |
120 |
360 |
225 |
210 |
540 |
|
32-12-15-1.1 |
32 |
12 |
15 |
2900 |
1.1 |
45 |
120 |
360 |
225 |
210 |
540 |
|
40-15-15-1.5 |
40 |
15 |
15 |
2900 |
1.5 |
48 |
120 |
360 |
225 |
210 |
540 |
|
40-15-30-2.2 |
40 |
15 |
30 |
2900 |
2.2 |
54 |
120 |
360 |
225 |
210 |
540 |
|
50-20-7-0.75 |
50 |
20 |
7 |
2900 |
0.75 |
51 |
145 |
440 |
275 |
185 |
520 |
GAK-50 |
50-10-10-0.75 |
50 |
10 |
10 |
2900 |
0.75 |
52 |
120 |
250 |
230 |
185 |
520 |
GAK-50 |
50-20-15-1.5 |
50 |
20 |
15 |
290 |
1.5 |
53 |
120 |
250 |
230 |
210 |
564 |
GAK-50 |
50-15-25-2.2 |
50 |
15 |
25 |
2900 |
2.2 |
54 |
145 |
410 |
245 |
205 |
550 |
GAK-50 |
50-18-30-3 |
50 |
18 |
30 |
2900 |
3 |
55 |
155 |
420 |
250 |
260 |
660 |
GAK-50 |
50-40-15-4 |
50 |
40 |
15 |
2900 |
4 |
55 |
140 |
457 |
264 |
310 |
730 |
GAK-50 |
50-25-32-5.5 |
50 |
25 |
32 |
2900 |
5.5 |
55 |
165 |
480 |
285 |
310 |
770 |
GAK-50 |
50-20-40-7.5 |
50 |
50 |
20 |
2900 |
7.5 |
58 |
175 |
480 |
285 |
310 |
770 |
GAK-50 |
65-25-15-2.2 |
65 |
25 |
15 |
2900 |
2.2 |
50 |
145 |
450 |
280 |
205 |
570 |
GAK-65 |
65-37-13-3 |
65 |
37 |
13 |
2900 |
3 |
57 |
165 |
475 |
305 |
260 |
652 |
GAK-65 |
65-25-30-4 |
65 |
25 |
30 |
2900 |
4 |
61 |
170 |
505 |
300 |
325 |
710 |
GAK-65 |
65-30-40-7.5 |
65 |
30 |
40 |
2900 |
7.5 |
56 |
|
|
|
|
|
GAK-65 |
65-35-50-11 |
65 |
35 |
50 |
2900 |
11 |
45 |
165 |
460 |
300 |
350 |
920 |
GAK-65 |
65-35-60-15 |
65 |
35 |
60 |
2900 |
15 |
65 |
165 |
460 |
300 |
350 |
920 |
GAK-65 |
80-60-13-5.5 |
80 |
60 |
13 |
2900 |
5.5 |
67 |
165 |
565 |
330 |
325 |
775 |
GAK-80 |
80-40-7-2.2 |
80 |
40 |
7 |
1450 |
2.2 |
59 |
165 |
510 |
330 |
260 |
640 |
GAK-80 |
80-43-13-3 |
80 |
43 |
13 |
2900 |
3 |
70 |
165 |
540 |
330 |
325 |
652 |
GAK-80 |
80-40-15-4 |
80 |
40 |
15 |
2900 |
4 |
61 |
180 |
565 |
330 |
325 |
775 |
GAK-80 |
80-65-25-7.5 |
80 |
65 |
25 |
2900 |
7.5 |
63 |
180 |
656 |
330 |
325 |
775 |
GAK-80 |
100-80-10-4 |
100 |
100 |
10 |
1450 |
4 |
65 |
220 |
700 |
430 |
420 |
800 |
GAK-100 |
model |
caliber |
internet traffic |
lift |
rotational speed |
power |
efficiency |
A |
B |
C |
D |
H |
automatic coupler |
mm |
(m3/h) |
(M) |
(r/min) |
(kw) |
(%) |
|||||||
100-100-15-7.5 |
100 |
100 |
15 |
1450 |
7.5 |
68 |
225 |
690 |
420 |
420 |
825 |
GAK-100 |
100-80-20-7.5 |
100 |
80 |
20 |
1450 |
7.5 |
65 |
225 |
690 |
420 |
420 |
825 |
GAK-100 |
100-100-25-11 |
100 |
100 |
25 |
1450 |
11 |
70 |
225 |
690 |
450 |
520 |
940 |
GAK-100 |
100-100-30-15 |
100 |
100 |
30 |
1450 |
15 |
65 |
|
|
|
|
|
GAK-100 |
100-100-35-18.5 |
100 |
100 |
35 |
1450 |
18.5 |
68 |
225 |
680 |
410 |
420 |
970 |
GAK-100 |
125-130-15-11 |
125 |
130 |
15 |
1450 |
11 |
72 |
|
|
|
|
|
GAK-125 |
125-130-20-15 |
125 |
130 |
20 |
1450 |
15 |
75 |
|
|
|
|
|
GAK-125 |
150-145-9-7.5 |
150 |
145 |
9 |
1450 |
7.5 |
76 |
225 |
800 |
510 |
420 |
795 |
GAK-150 |
150-180-15-15 |
150 |
180 |
15 |
1450 |
15 |
69 |
275 |
950 |
610 |
520 |
1060 |
GAK-150 |
150-180-20-18.5 |
150 |
180 |
20 |
1450 |
18.5 |
72 |
250 |
925 |
858 |
520 |
1060 |
GAK-150 |
150-180-25-22 |
150 |
180 |
25 |
1450 |
22 |
78 |
260 |
925 |
585 |
520 |
1060 |
GAK-150 |
150-130-30-22 |
150 |
130 |
30 |
1450 |
22 |
78 |
260 |
925 |
585 |
520 |
1060 |
GAK-150 |
150-180-30-30 |
150 |
180 |
30 |
1450 |
30 |
78 |
|
|
|
|
|
GAK-150 |
150-200-30-37 |
150 |
200 |
30 |
1450 |
37 |
73 |
275 |
1025 |
650 |
520 |
1320 |
GAK-150 |
200-300-7-11 |
200 |
300 |
7 |
980 |
11 |
66 |
290 |
990 |
610 |
520 |
1150 |
GAK-200 |
200-250-11-15 |
200 |
250 |
11 |
1450 |
15 |
64 |
270 |
970 |
600 |
520 |
1120 |
GAK-200 |
200-250-15-18.5 |
200 |
250 |
15 |
1450 |
18.5 |
73 |
290 |
1130 |
715 |
520 |
1130 |
GAK-200 |
200-400-10-22 |
200 |
400 |
10 |
1450 |
22 |
75 |
275 |
1120 |
710 |
520 |
1130 |
GAK-200 |
200-400-13-30 |
200 |
400 |
13 |
14501 |
30 |
76 |
275 |
1120 |
710 |
520 |
1320 |
GAK-200 |
200-300-15-22 |
200 |
300 |
15 |
1450 |
22 |
76 |
275 |
1120 |
710 |
520 |
1130 |
GAK-200 |
200-250-22-30 |
200 |
250 |
22 |
1450 |
30 |
71 |
275 |
1120 |
710 |
520 |
1290 |
GAK-200 |
200-350-25-37 |
200 |
350 |
25 |
1450 |
37 |
71 |
325 |
1080 |
680 |
520 |
1370 |
GAK-200 |
200-400-30-45 |
200 |
400 |
30 |
1450 |
45 |
74 |
330 |
1250 |
780 |
520 |
1370 |
GAK-200 |
model |
caliber |
internet traffic |
lift |
rotational speed |
power |
efficiency |
A |
B |
C |
D |
H |
automatic coupler |
mm |
(m3/h) |
(M) |
(r/min) |
(kw) |
(%) |
|||||||
250-600-9-30 |
250 |
600 |
9 |
980 |
30 |
78 |
440 |
1100 |
700 |
520 |
1660 |
GAK-250 |
250-600-12-37 |
250 |
600 |
12 |
1450 |
37 |
76 |
440 |
1100 |
700 |
520 |
1660 |
GAK-250 |
250-600-15-45 |
250 |
600 |
15 |
1450 |
45 |
73 |
440 |
1100 |
700 |
520 |
1660 |
GAK-250 |
250-600-20-55 |
250 |
600 |
20 |
1450 |
55 |
73 |
440 |
1100 |
700 |
520 |
1700 |
GAK-250 |
250-600-25-75 |
250 |
600 |
25 |
1450 |
75 |
71 |
440 |
1100 |
700 |
520 |
1750 |
GAK-250 |
300-800-12-45 |
300 |
800 |
12 |
980 |
45 |
74 |
470 |
1305 |
850 |
650 |
1845 |
GAK-300 |
300-480-15-45 |
300 |
480 |
15 |
1450 |
45 |
66 |
470 |
1305 |
850 |
650 |
1845 |
GAK-300 |
300-800-15-55 |
300 |
800 |
15 |
1450 |
55 |
73 |
470 |
1305 |
850 |
650 |
2060 |
GAK-300 |
300-600-20-55 |
300 |
600 |
20 |
1450 |
55 |
73 |
470 |
1305 |
850 |
650 |
2060 |
GAK-300 |
300-800-20-75 |
300 |
800 |
20 |
1450 |
75 |
75 |
470 |
1305 |
850 |
650 |
2120 |
GAK-300 |
300-950-20-90 |
300 |
950 |
20 |
1450 |
90 |
76 |
470 |
1305 |
850 |
650 |
2120 |
GAK-300 |
300-1000-25-110 |
300 |
1000 |
25 |
1450 |
110 |
76 |
500 |
1350 |
875 |
650 |
2220 |
GAK-300 |
300-1100-10-55 |
300 |
1100 |
10 |
1450 |
55 |
73 |
|
|
|
|
|
GAK-300 |
350-1500-15-90 |
350 |
1500 |
15 |
740 |
90 |
87 |
630 |
1533 |
1280 |
700 |
2190 |
GAK-350 |
350-1200-18-90 |
350 |
1200 |
18 |
980 |
90 |
85 |
500 |
900 |
500 |
750 |
2190 |
GAK-350 |
350-1100-28-132 |
350 |
1100 |
28 |
980 |
132 |
84 |
700 |
1616 |
1363 |
700 |
2480 |
GAK-350 |
350-1000-36-160 |
350 |
1000 |
36 |
980 |
160 |
84 |
700 |
1666 |
1413 |
700 |
2590 |
GAK-350 |
400-1760-7.5-55 |
400 |
1760 |
7.5 |
980 |
55 |
83 |
|
|
|
|
|
GAK-400 |
400-1500-10-75 |
400 |
1500 |
10 |
980 |
75 |
86 |
600 |
1650 |
1365 |
780 |
2000 |
GAK-400 |
400-2000-13-110 |
400 |
2000 |
13 |
980 |
110 |
84 |
600 |
1650 |
1365 |
780 |
2280 |
GAK-400 |
400-2000-15-132 |
400 |
2000 |
15 |
980 |
132 |
83 |
|
|
|
|
|
GAK-400 |
400-1700-22-160 |
400 |
1700 |
22 |
980 |
160 |
83 |
630 |
1670 |
1380 |
780 |
2600 |
GAK-400 |
400-1500-26-160 |
400 |
1500 |
26 |
980 |
160 |
84 |
630 |
1670 |
1380 |
780 |
2600 |
GAK-400 |
model |
caliber |
internet traffic |
lift |
rotational speed |
power |
efficiency |
A |
B |
C |
D |
H |
automatic coupler |
mm |
(m3/h) |
(M) |
(r/min) |
(kw) |
(%) |
|||||||
400-1800-32-250 |
400 |
1800 |
32 |
980 |
250 |
82 |
670 |
1730 |
1440 |
780 |
2850 |
GAK-400 |
500-2500-10-110 |
500 |
2500 |
10 |
740 |
110 |
85 |
900 |
2218 |
1875 |
900 |
2250 |
GAK-500 |
500-2600-15-160 |
500 |
2600 |
15 |
740 |
160 |
84 |
955 |
1968 |
1625 |
900 |
2450 |
GAK-500 |
500-2400-22-220 |
500 |
2400 |
22 |
740 |
220 |
85 |
900 |
2218 |
1875 |
900 |
2520 |
GAK-500 |
500-2650-24-250 |
500 |
2650 |
24 |
740 |
250 |
85 |
1017 |
2198 |
2395 |
900 |
3000 |
GAK-500 |
Please provide as much as possible for ordering:1. Model2. Caliber3. Head (m)4. Traffic5. Motor power (KW)6. Speed (R/min)7. Voltage (V)8. Does the material come with accessories