voltage |
DC12V |
power |
1W when there is no alarm, 9W for all defense zones alarms |
operation temperature |
-25℃-60℃ |
Output |
32 channels of 12V output |
output current |
<100mA |
Communication method |
RS485 bus |
size |
133mm(L)*97mm(W)*17mm(H) |
Functional features:
1. Each electronic map module supports 31 zone setting dip switches, with 8 addresses corresponding to a total of 255 zones.
2. Each output signal can be directly driven by a constant voltage source to provide a driving current of over 100mA for the LED indicator light.
3. Flexible installation method. When the total power is less than 5W, power can be directly supplied through the alarm keyboard YR-LC-TX/KB2 and YR-LC-TX/KB3 network interfaces.