4) Semi automatic 884 professional volt ampere polarograph
The 884 Professional VA semi-automatic professional volt ampere polarograph using MME (multi-mode electrode) is an easy-to-use analyzer that can be us
Product details

Order number: 2.884.1110

useMMESemi automatic professional volt ampere polarograph with multi-mode electrode884 Professional VAIt is an easy-to-use analyzer that can use multi-mode electrodesproOrscTRACE GoldPerform trace measurements using voltammetry and polarography. This confirmed Swiss Wanton electrode technology and newly designed constant potential/Constant current meter and external high-performance viva The combination of software has shown new prospects in the field of heavy metal determination. The potentiostat with a certified calibrator automatically flushes for calibration before each measurement to ensure possible high accuracy.

This instrument can also be used for measurement using a rotating disk electrode, for example, with the help of«Cyclic voltammetry dissolution method»CVS)The«Cyclic pulse voltammetry dissolution method»CPVS)The chronopotentiometric method(CP)Determine the organic additives in the electroplating solution. With the help of replaceable measuring heads, quick switching between various applications using different electrodes can be achieved.

Two randomly equipped liquid filling units800 DosinoAuxiliary solutions such as electrolytes, buffer solutions, or standard solutions can be automatically added during the measurement process.

use viva Software is used for instrument control, data acquisition, and evaluation.

useMMESemi automatic professional volt ampere polarograph with multi-mode electrode884 Professional VAComes with a large number of accessories during supply, including those for multi-mode electrodesproThe measuring head. Electrode kit and viva The license must be ordered separately.

Technical parameters:

Size remarks

No attachments

Size, unit:mm(Wide)/high/Deep)

188/294/406

technical parameter

Potentiostat

·Maximum output voltage:±25 V

·Maximum output current:± 224 mA

·Scanning voltage range:±5 V

·Resolution of measured current (within the minimum measurement range):6 fA

Current measurement technology

·DP«Differential pulse»

·SQW«square wave»

·CVS«Cyclic voltammetry dissolution method»

·CPVS«Cyclic pulse voltammetry dissolution method»

·CP(Timing potential method, constant current and measurement of open circuit point)

Correction technology

·standard addition method

·External correction

·DT(Dilution titration method)

·LAT(Linear approximation method)

·MLAT(Improved Linear Approximation Method)

·RC(Response curve)

Working electrode

·Multi-Mode-Elektrode pro

·scTRACE Gold

·Rotating disk electrode(Rotating disk electrodesRDE)The material is glassy carbon(Glassy Carbon)The“Ultra Trace”(Ultra trace) graphitePt(Platinum)Ag(Silver)Au(Gold)

·revolutions:100 To3000 min-1

Reference electrode

·Ag/AgCl/KCl 3 mol/L

Auxiliary electrode

·Pt(Platinum)

·Glassy carbon(Glassy CarbonGC

port/Interface

·Built inUSBInterface

·MSBInterface, used to connect up to four devices800 DosinoOr other attachments

·Measurement input terminal, used for temperature measurement(Pt1000