ADVION CMS series rapid mass spectrometer from the United States
Advion provides a range of small desktop mass spectrometers from the United States, which are cost-effective, compact in appearance, easy to operate,
Product details
Advion provides a range of small desktop mass spectrometers from the United States, which are cost-effective, compact in appearance, easy to operate, and can easily switch between five injection methods. They are suitable for operation in fume hoods and can directly and quickly obtain mass analysis results within seconds, improving work efficiency.
As an expert with over 20 years of experience in mass spectrometry production, Advion from the United States offers a range of small desktop mass spectrometers that are cost-effective, compact in appearance, easy to operate, and can easily switch between five injection methods. They are suitable for placement in fume hoods for quick and direct analysis results, improving work efficiency. Every organic synthesis chemist should have a small desktop mass spectrometer to ensure efficient laboratory work.


Product Model:
Expression S
Expression S is designed for organic synthesis chemists, flexible, convenient, and suitable for analyzing small molecule compounds. The measurement range can reach m/z 1000.
Expression L
Expression L is designed to meet the higher quality testing range requirements of chemists, with a measurement range of up to m/z 2000.
Typical applications:
Monitoring response:
• Can continuously and massively identify compounds
• Can quickly and accurately characterize and measure purity
Purification:
Can be used for rapid chromatography, preparative chromatography (Prep LC), and supercritical fluid chromatography (SFC) to collect samples of different masses TLC (Thin Layer Chromatography) - CMS:
• Unique user interface can be directly used for quality analysis of TLC spots
• Can be used for quality analysis of reaction mixtures and chromatographic components
More applications:
Peptide synthesis, capable of batch processing and online monitoring
• Polymer Chemistry
• Natural products
• Can be used in combination with all brands (U) HPLC
• Food safety testing
• Water quality monitoring
Clinical diagnosis, teaching, research, etc
Product Features:
The expression CMS can be placed on a handcart and quickly moved within the laboratory, making it convenient for various applications. The rapid vacuum system ensures that the expression CMS can start measuring samples after 30 minutes of movement.
∴ Simple operation and strong practicality
The small desktop mass spectrometer is easy to operate for direct sample analysis. Students immerse the capillary probe into the reaction mixture and then insert the probe into the mass spectrometer for analysis, without the need for additional sample preparation and analysis. Small desktop mass spectrometer has strong practicality and can directly inject liquid/solid samples TLC-CMS、(U)HPLC-CMS、 The real-time integration and easy conversion of five injection methods, namely preparative chromatography CMS and flow injection analysis CMS, make it easier for students to learn multiple injection techniques and add a skill to their future work.
The I/O port synchronizes and transfers data with external devices, and can be used in conjunction with various chromatographic devices. It has strong flexibility and versatility, and can be applied to all workflows in scientific research.
Compatible with all liquid phase systems
The expression CMS is compatible with Agilent's entire range of liquid chromatography systems, and for users using the Agilent Instrument Control Framework (ICF), the operating interface for Agilent and Adivion mass spectrometry is the same.The DataApex Clarity chromatography workstation has strong compatibility and can be connected to over 250 liquid chromatographs. It comes with its ownThe mass spectrometry database fully supports CFR21 Part 11 electronic signature authentication.
Easy conversion of multiple injection methods
Place the expression CMS at the center of the organic synthesis laboratory workflow, which can directly inject liquid/solid samples TLC-CMS、(U)HPLC-CMS、 The five injection methods of preparative chromatography CMS and flow injection analysis CMS are instantly integrated and easily converted, without the need for additional operations such as reconnecting pipelines and configuring systems.
Advanced design concepts simplify operating procedures
The expression CMS adopts a unique atmospheric pressure ionization interface design and is one of the early small desktop mass spectrometers that can be used in fume hoods. All key operations and daily maintenance can be carried out from the front of the instrument, making daily use and routine maintenance of the instrument simple and easy. The corrosion-resistant shell material, enclosed N2 purification components, and closed circuits greatly ensure the safety of operation.
A powerful and user-friendly workstation
Data express data processing software can provide both simple result analysis and deep mining of your data. At the same time, Data Express can accurately monitor reactions in real-time, facilitating timely target determination, accelerating workflow, and quickly moving on to the next research topic.
∴ Available for students to operate during class
Teaching mass spectrometer makes course learning easy and understandable
∴ Can provide instructional videos
We can provide video lectures by Dr. Jack Henion, an honorary professor at Cornell University, focusing on key areas of interest for students, whether they are in academia, industry, or government in the future. These courses benefit them for life. The course content includes:
1. Introduction to Mass Spectrometry
2. Direct injection injection (flow injection analysis)
3. Direct Sample Analysis Probe (ASAP)
4. Thin layer analysis mass spectrometry analysis
5. Liquid chromatography-mass spectrometry combined with LC/MS
6. Applications and techniques of other liquid injection mass spectrometry technologies
Expression S
Expression S is designed for organic synthesis chemists, flexible, convenient, and suitable for analyzing small molecule compounds. The measurement range can reach m/z 1000.
Expression L
Expression L is designed to meet the higher quality testing range requirements of chemists, with a measurement range of up to m/z 2000.
Typical applications:
Monitoring response:
• Can continuously and massively identify compounds
• Can quickly and accurately characterize and measure purity
Purification:
Can be used for rapid chromatography, preparative chromatography (Prep LC), and supercritical fluid chromatography (SFC) to collect samples of different masses TLC (Thin Layer Chromatography) - CMS:
• Unique user interface can be directly used for quality analysis of TLC spots
• Can be used for quality analysis of reaction mixtures and chromatographic components
More applications:
Peptide synthesis, capable of batch processing and online monitoring
• Polymer Chemistry
• Natural products
• Can be used in combination with all brands (U) HPLC
• Food safety testing
• Water quality monitoring
Clinical diagnosis, teaching, research, etc
Product Features:
ESI, APCI, and ASAP ion sources can be freely selected to meet the mass spectrometry analysis of different compounds. We can provide customized services according to customer needs.
∴ Convenient to move
The expression CMS can be placed on a handcart and quickly moved within the laboratory, making it convenient for various applications. The rapid vacuum system ensures that the expression CMS can start measuring samples after 30 minutes of movement.
∴ Simple operation and strong practicality
The small desktop mass spectrometer is easy to operate for direct sample analysis. Students immerse the capillary probe into the reaction mixture and then insert the probe into the mass spectrometer for analysis, without the need for additional sample preparation and analysis. Small desktop mass spectrometer has strong practicality and can directly inject liquid/solid samples TLC-CMS、(U)HPLC-CMS、 The real-time integration and easy conversion of five injection methods, namely preparative chromatography CMS and flow injection analysis CMS, make it easier for students to learn multiple injection techniques and add a skill to their future work.
The I/O port synchronizes and transfers data with external devices, and can be used in conjunction with various chromatographic devices. It has strong flexibility and versatility, and can be applied to all workflows in scientific research.
Compatible with all liquid phase systems
The expression CMS is compatible with Agilent's entire range of liquid chromatography systems, and for users using the Agilent Instrument Control Framework (ICF), the operating interface for Agilent and Adivion mass spectrometry is the same.The DataApex Clarity chromatography workstation has strong compatibility and can be connected to over 250 liquid chromatographs. It comes with its ownThe mass spectrometry database fully supports CFR21 Part 11 electronic signature authentication.
Easy conversion of multiple injection methods
Place the expression CMS at the center of the organic synthesis laboratory workflow, which can directly inject liquid/solid samples TLC-CMS、(U)HPLC-CMS、 The five injection methods of preparative chromatography CMS and flow injection analysis CMS are instantly integrated and easily converted, without the need for additional operations such as reconnecting pipelines and configuring systems.
Advanced design concepts simplify operating procedures
The expression CMS adopts a unique atmospheric pressure ionization interface design and is one of the early small desktop mass spectrometers that can be used in fume hoods. All key operations and daily maintenance can be carried out from the front of the instrument, making daily use and routine maintenance of the instrument simple and easy. The corrosion-resistant shell material, enclosed N2 purification components, and closed circuits greatly ensure the safety of operation.
A powerful and user-friendly workstation
Data express data processing software can provide both simple result analysis and deep mining of your data. At the same time, Data Express can accurately monitor reactions in real-time, facilitating timely target determination, accelerating workflow, and quickly moving on to the next research topic.
∴ Available for students to operate during class
Teaching mass spectrometer makes course learning easy and understandable
∴ Can provide instructional videos
We can provide video lectures by Dr. Jack Henion, an honorary professor at Cornell University, focusing on key areas of interest for students, whether they are in academia, industry, or government in the future. These courses benefit them for life. The course content includes:
1. Introduction to Mass Spectrometry
2. Direct injection injection (flow injection analysis)
3. Direct Sample Analysis Probe (ASAP)
4. Thin layer analysis mass spectrometry analysis
5. Liquid chromatography-mass spectrometry combined with LC/MS
6. Applications and techniques of other liquid injection mass spectrometry technologies
Online inquiry
