APD type residual pressure valve
APD type residual pressure valve can be widely used in purification workshops or clean rooms to maintain a positive pressure difference between indoor
Product details
APDType residual pressure valve
This device can be widely used in purification workshops or clean rooms to maintain a positive pressure difference between indoors and outdoors, allowing excess indoor air to be expelled and preventing outdoor air from entering.
Feature 1: The installation form is wall mounted, and the wall thickness can be adjusted freely within 30-50mm.
2. The position of the heavy hammer can be adjusted according to the requirements of air volume and pressure difference.
Technical Specifications
model
APD-10C
APD-6C
Initial pressure difference
0.5mmAq
0.5mmAq
Range of pressure difference used
0.5∽25mmAq
0.5∽25mmAq
Air volume
0∽900m3/h
0∽600m3/h
Installation of empty space size
560W×360Hmm
400W×200Hmm