Product Description:
The accelerometer force balance accelerometer Columbia SA100MR provides excellent performance in force balance technology and flexibility in multiple operating ranges for DC and low-frequency measurements. The accelerometer is independent and provides a high-level, low impedance output. In most applications, signal conditioning is not required. To order an accelerometer, the complete range of SA-100MR must be specified. Then the range can be adjusted from 0.05 to 1 times the entire range through an external resistor. The selected range always corresponds to an output of ± 7.5 volts. The background noise remains constant and does not increase with the increase of the scaling factor, thus achieving the best signal-to-noise ratio within any selected range.
working principle:
The force balance accelerometer has a classical critical damping and second-order frequency response. There is no peak in the response, only a smooth roll off above the natural frequency. This feature, along with the excellent design of the "HP" torque generator, makes the Columbia accelerometer the best choice for high demand applications for precise DC and near DC measurements in harsh impact and broadband vibration environments. Columbia force balance accelerometers can be used for almost all applications. Low noise, high output components can be used for seismic structural motion research, while miniature, high range versions are more suitable for the more intense high-G environments encountered in many industrial, aircraft, and missile applications.
The Columbia force balanced linear accelerometer series offers low-cost, high-performance, universal single axis accelerometers that are ideal for DC and low-frequency measurements, and provide voltage and current signal outputs. In addition, solid-state sensors from Colombia and specialized onboard sensors are also available, with outputs specifically designed for+24 to+32VDC aircraft power supply, making them ideal for onboard telemetry applications. Columbia low-noise sensors are designed specifically for earthquake, low-level, and low-frequency motion research.
Accelerators - Force Balance Accelerators - Columbia SA100MR Product Highlights:
- Uniaxial linearity
- Universal type
- +/-15 VDC operation
- Low cost, high performance
- Range optional
Application scope:
- Airborne telemetry
- Research on Low Frequency Motion
- Research on earthquake motion
- Aviation and missile applications
- Turbine vibration measurement
- Military and civilian flight simulators
- Traffic system monitoring and roadbed analysis
- Crash records, fatigue monitoring, and prediction
- Automotive chassis measurement
Upgrade options:
- High performance linear accelerometer
- Dual axis linear accelerometer
- Three-axis linear accelerometer
- Linear accelerometer switch
- Angular accelerometer
Technical parameters:
Operating parameters:
Available full-scale range:+ 1G, + 5G, + 10G, + 50G
Output voltage: ± 7.5 V, F.R to F 10% adjustable for R
Incentive source: ± 12-15 VDC, 0-50 mA
Output impedance: Typical 100 Ohms
Sensitive axis alignment: better than 0.25 Deg
Scale factor tolerance: nominal value ± 1%
Proportional factor temperature coefficient: ± 0.02%/Deg C
Zero deviation: ± 0.15% F R
Zero temperature sensitivity: 0.00015% F.R/Deg C
Natural frequency: 50-500 Hz Min, depending on the range
Damping: 0.7 ± 0.1 or 0.2
Output noise: 0.002 V RMS, independent of S R
Horizontal axis sensitivity: 0.002 G/G, except for axis alignment
Nonlinear: ± 0.05% F.R - ± 0.2% F.R
Hysteresis and non repeatability: 0.02% F.R
Threshold and Resolution: ± 0.0005% F.R
Environmental parameters:
Operating temperature: -50 to+85 Deg C
Storage temperature: -50 to+85 Deg C
Vibration resistance (2-2000Hz): Range ± 1G, 5G P/P
Range: ± 5G, ± 10G, ± 50G, 10 G P/P
Impact resistance: Range ± 1G, 50G, 1 mSec half sine
Range ± 5G, ± 10G, ± 50G, 150G, 1 mSec half sine
Environmental pressure: 0-5 atmospheres
Humidity: 95% R.H
Physical parameters:
Weight: 4 Oz (113.4 Gm)
Dimensions (LWH): 3.09x 1.38x 1.34 In/79.5 x 35.1 x 34.1 cm
Shell material: anodized aluminum
Sealing method: Environment
Electrical interface: 5-port pins