Tengzhou Zhongke Spectral Analysis Instrument Co., Ltd
Home>Products>Acetone chromatography packed column
Product Groups
Firm Information
  • Transaction Level
    VIP member
  • Contact
  • Phone
    18663278921
  • Address
    No. 20, Xibeitan, Tengzhou City, Shandong Province
Contact Now
Acetone chromatography packed column
Product Introduction: The acetone chromatography packed column provided by Tengzhou Zhongke Spectral Analysis Instrument is mainly used for analyzing
Product details
brand ZKP/Zhongkepu Supply cycle in stock
application area Healthcare, biotechnology, agriculture specifications 3mm*3m

[Product Introduction]

Acetone chromatography packed columnAlso known as gas chromatography column, tetrafluoroethylene chromatography packed column

Property: Strong polarity

Application: Analysis of water, methanol, ethanol in acetone

Temperature range: 0 to 200 ℃, conventional

[Product Price List]

Acetone chromatography column (60-80), diameter 3 (outer diameter) x 2m (length) 600

Acetone chromatography column (60-80), diameter 3 (outer diameter) x 3m (length) 800

【 Installation Method 】

Acetone chromatography packed columnThe installation at the injector and detector is similar. One end of the injector for filling the column should leave a sufficient gap (at least 50mm) to prevent the inserted syringe needle from touching the glass fiber or column filling material filled at the column end; At one end of the detector, there should also be enough empty column (at least 40mm) to prevent the bottom of the nozzle from touching the glass fiber or column filling material filled at the column end. As shown in the following figure

丙酮色谱填充柱

Note: After the installation of the chromatographic column, all joints, including the pressure reducing valve joint, purification tube joint, chromatographic column joint, injector, and detector, should be checked for leaks with soapy water to ensure the airtightness of the entire gas circuit.


(Customization can be made according to user requirements)

Chromatographic analysis conditions

Detector; thermal conductivity detector

Carrier gas: Hydrogen pressure 0.15Mpa

Chromatographic column GDX-104 2m * 4mm 80-100 mesh

Column temperature: 130 ℃

Gasification chamber temperature 170 ℃

Detector temperature 150 ℃

Injection volume 3UL

Peak order: Water, methanol, ethanol, acetone

Analysis spectrum:

丙酮色谱填充柱

Application case of packed column (gas chromatography)

product name

specifications

price

application

Pesticide residue analysis column

2m glass


Organochlorine and organophosphate pesticide residues

Liquefied gas analysis column

9m stainless steel


C1 to C5 alkane and alkene isomers

Natural gas analysis column

9m stainless steel


C1 to C5 alkanes and CO2

Solvent residue column (pharmacopoeia method)

2m stainless steel


Residual organic solvents in drugs

Baijiu analysis column

2m stainless steel


Methanol, fusel and total ester in Baijiu

Preservative analysis column

2m glass


Sorbic acid, benzoic acid

High performance 5A molecular sieve

2m stainless steel


H2, O2, N2, CH4, CO, separate

High performance carbon molecular sieve

2m stainless steel


H2, O2, N2, CH4, CO,CO2separate

Molecular sieve protection column

0.2m stainless steel


Extend the service life of 5A molecular sieve column

After sales guarantee: The company sellsStable quality, excellent quality, and cooperation with many chromatography manufacturers at home and abroad. The company provides services to users and promises to return or exchange products sold without reason within 7 days
Note: We can customize various types of stainless steel filled columns, glass filled columns, and polytetrafluoroethylene filled columns for customers according to their needs





Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!