Agilent Impedance Tester E5071C
Details
1.productpurpose
agilentImpedance analyzer hasThe impedance range from m Ω to M Ω and the frequency range from 5 Hz to 20 GHz provide unparalleled measurement accuracy for components compared to similar products. Using an impedance analyzer in the laboratory to achieve truly high-quality component feature measurement.
E5071C - TDR, suitable for high-frequency circuit board characteristic impedance testing, for PCB/FPCThe manufacturer provides a set of fast, accurate, standardized, and economicalTDR characteristic impedance testing solution; It can also be used for testing wires and cables. There are obvious measurement advantages for high-end communication boards.
2.Product Features
①Adjustable probe: direct testingInternal impedance lines on PCB boards can also be tested for impedance bars
② The spacing between the needles can be adjusted so that the probe can directly test the internal impedance of the board without being restricted by the spacing between the impedance wires.
③In the time domain(Simultaneous measurement in both TDR/TDT and frequency domain (S-parameter)
④Three breakthrough features are provided for signal integrity design and verification: simple and intuitive operation, fast and accurate measurement, and reliableESD
⑤provideA wide dynamic range of 130 dB, fast measurement speed of 8 ms, and temperature stability of 0.005 dB/℃ can improve measurement accuracy, increase product yield, and increase design margin.
3.TECHNICAL INDEX
Serial Number |
Agilent Impedance Project |
Technical capabilities |
notes |
1 |
Impedance value testing range |
20-200Ω |
/ |
2 |
precision |
±1% |
For standard components |
3 |
Impedance line length |
8.5G bandwidth ≥30mm |
5G communication board impedance line is very short, Agilent from the United States Impedance machines can test high-end communication boards, |
4 |
impedance bandwidth |
8.5 G/20G optional |
The higher the bandwidth, the stronger the testing capability. The impedance of 3G bandwidth is somewhat outdated in the era of 5G communication |
5 |
measurement speed |
41ms |
Each impedance test time is less than1s |
6 |
stability |
0.005 dB/℃ |
|
7 |
Can the impedance inside the board be tested |
can |
Agilent's adjustable probe can directly test the internal impedance line of the board without testing the impedance strip. |
8 |
Frequency offset mode option |
have |
/ |
9 |
TDR Time Domain Options |
have |
Used for testing impedance |
10 |
testing environment |
Room temperature is sufficient without the need for a separate anti-static room |
Built in anti-static module in the machine |
4. Configuration details
Serial Number
Accessory Name
quantity
notes
1
E5071C-8.5G/20G host optional
1 unit
standard configuration
2
Agilent's original TDR measurement software
1 set
Standard configuration
3
Single ended, differential fixed probe
1 each
Standard configuration
4
Cable line
2 items
Standard configuration
5
Adjustable probe
1 piece
Optional
6
Third party TDR measurement software (automatically judges data)
1 set
Optional
[Return]