Air cooled chillers HC025~HC035 series
Function introduction: The HC025-HC035 series chillers have three commonly used temperature control accuracies to choose from, meeting different needs
Product details

HC025~HC035 series

Product Features

  • Multiple temperature control precision options to meet different needs, with optional temperature control accuracies of ± 0.1 ℃, ± 1.0 ℃, and ± 2.5 ℃

  • Single temperature multi cycle system, capable of up to three inputs and three outputs

  • Efficient plate heat exchangers or corrosion-resistant titanium tube heat exchangers can be selected

  • External rotor fan, integrated air-cooled heat dissipation (optional water cooling method), side air outlet method

  • Equipped with liquid level alarm, flow alarm, temperature alarm, pressure alarm, and component fault alarm

  • Equipped with flow alarm, temperature alarm, and temperature ready signal output (optional)

  • Equipped with universal casters (two sets of casters with brakes) for easy movement of the unit

  • Equipped with external control start and stop functions (optional)

  • Equipped with heating function to achieve rapid temperature rise in low-temperature environments (optional)

  • Adopting stainless steel water pump and PP/PE water tank, the water circulation system does not contain metals such as copper, aluminum, iron, etc., and will not rust at all

  • Circulating water fine filtration, filtration accuracy can be selected according to actual needs

Function Introduction

  • The HC025-HC035 series chillers have three commonly used temperature control accuracies to choose from, meeting different needs. The practical cooling capacity of the unit ranges from 2500W to 3500W, which can meet the cooling requirements for long-term stable operation of heating equipment with a heat generation of ≤ 3.5KW. The cooling methods of chillers include air-cooled cooling and water-cooled cooling. The air-cooled cooling method is easy to use and does not require external cooling water connection; Water cooling heat dissipation method, the heat of the chiller will be carried to the external environment by the cooling water, without increasing the indoor heat. Both heat dissipation methods have their own advantages and disadvantages.

Application scope

Lamp pumped laser/CO2 laser/fiber laser/LED light source/injection molding machine/plasma cutting equipment/die-casting machine/reactor/medium high frequency induction equipment/CNC machine tool/high-speed shaft/high-power linear motor/high-precision positioning beam, etc

HC025~HC035 series

Product Features

  • Multiple temperature control precision options to meet different needs, with optional temperature control accuracies of ± 0.1 ℃, ± 1.0 ℃, and ± 2.5 ℃

  • Single temperature multi cycle system, capable of up to three inputs and three outputs

  • Efficient plate heat exchangers or corrosion-resistant titanium tube heat exchangers can be selected

  • External rotor fan, integrated air-cooled heat dissipation (optional water cooling method), side air outlet method

  • Equipped with liquid level alarm, flow alarm, temperature alarm, pressure alarm, and component fault alarm

  • Equipped with flow alarm, temperature alarm, and temperature ready signal output (optional)

  • Equipped with universal casters (two sets of casters with brakes) for easy movement of the unit

  • Equipped with external control start and stop functions (optional)

  • Equipped with heating function to achieve rapid temperature rise in low-temperature environments (optional)

  • Adopting stainless steel water pump and PP/PE water tank, the water circulation system does not contain metals such as copper, aluminum, iron, etc., and will not rust at all

  • Circulating water fine filtration, filtration accuracy can be selected according to actual needs

Function Introduction

  • The HC025-HC035 series chillers have three commonly used temperature control accuracies to choose from, meeting different needs. The practical cooling capacity of the unit ranges from 2500W to 3500W, which can meet the cooling requirements for long-term stable operation of heating equipment with a heat generation of ≤ 3.5KW. The cooling methods of chillers include air-cooled cooling and water-cooled cooling. The air-cooled cooling method is easy to use and does not require external cooling water connection; Water cooling heat dissipation method, the heat of the chiller will be carried to the external environment by the cooling water, without increasing the indoor heat. Both heat dissipation methods have their own advantages and disadvantages.

Application scope

Lamp pumped laser/CO2 laser/fiber laser/LED light source/injection molding machine/plasma cutting equipment/die-casting machine/reactor/medium high frequency induction equipment/CNC machine tool/high-speed shaft/high-power linear motor/high-precision positioning beam, etc

工业冷水机--风冷冷水机HC025~HC035系列 (2).png

工业冷水机--风冷冷水机HC025~HC035系列 (3).png

Function Introduction:

The HC025-HC035 series chillers have three commonly used temperature control accuracies to choose from, meeting different needs. The practical cooling capacity of the unit ranges from 2500W to 3500W, which can meet the cooling requirements for long-term stable operation of heating equipment with a heat generation of ≤ 3.5KW. The cooling methods of chillers include air-cooled cooling and water-cooled cooling. The air-cooled cooling method is easy to use and does not require external cooling water connection; Water cooling heat dissipation method, the heat of the chiller will be carried to the external environment by the cooling water, without increasing the indoor heat. Both heat dissipation methods have their own advantages and disadvantages.

Application scope:

Lamp pumped laser/CO2 laser/fiber laser/LED light source/injection molding machine/plasma cutting equipment/die-casting machine/reactor/medium high frequency induction equipment/CNC machine tool/high-speed shaft/high-power linear motor/high-precision positioning beam, etc