Shanghai Gaotian Pump Co., Ltd
Home>Products>Automatic fire pump unit equipment
Firm Information
  • Transaction Level
    VIP member
  • Contact
  • Phone
  • Address
    No. 178 Linsheng Road, Industrial South Zone, Tinglin Town, Jinshan District, Shanghai
Contact Now
Automatic fire pump unit equipment
Suitable for fire hydrant water supply systems and automatic sprinkler systems with pressurization requirements in multi story and high-rise building
Product details

The variable frequency fire water supply equipment adopts a combination configuration of fire water pumps that meet national requirements, ensuring the performance of the equipment. The equipment can always maintain the required fire flow and pressure for unfavorable points in the fire water supply system. Once a fire occurs, the fire hydrant or automatic nozzle will release water, the pressure will decrease, and an alarm will be triggered to immediately start the fire main pump. It can also be connected to the signal network of the fire button, water flow indicator, and wet alarm valve, and controlled by the fire control room for start and stop.

Product Name: Takata Variable Frequency Firefighting Water Supply Equipment
Caliber range: GTD253
Flow range: 2-160m3/h
Head range: 24-200m
Our advantages: fast delivery time, all accessories use domestic and foreign brand products, stable product performance, and a service life of more than 10 years
Selection quotation: You only need to provide the number of households and the number of floors in the community, and we can provide you with a selection quotation

overview
The Takata variable frequency fire water supply equipment adopts a combination configuration of fire water pumps that meet national requirements, ensuring the performance of the equipment. The equipment can always maintain the required fire flow and pressure for unfavorable points in the fire water supply system. Once a fire occurs, the fire hydrant or automatic nozzle will release water, the pressure will decrease, and an alarm will be triggered to immediately start the fire main pump. It can also be connected to the signal network of the fire button, water flow indicator, and wet alarm valve, and controlled by the fire control room for start and stop. When equipped with an automatic air supply tank, there is no need for an air compressor. The nitrogen cylinder can be inflated and automatically adjusted to ensure the appropriate gas water ratio, efficiently utilizing the total volume of the pressure tank.



Working principle
When the system is in a stable state, due to the discharge of some gas from the water in the pressure tank, the pressure inside the tank decreases. When it reaches a certain pressure, the pressure sensor sends a signal to open the solenoid valve through the electric control box to discharge the water in the tank. When the water level drops to the lower limit, the solenoid valve closes and the liquid level sensor sends a signal to control the water replenishment pump to start working, replenishing water and air to the pressure tank.

When the water level reaches the upper limit, the actual water pump stops, but when the pressure inside the tank does not reach the set working pressure, the solenoid valve opens and the tank drains. When the water level reaches the lower limit, the water replenishment pump starts again and cycles multiple times until the pressure and water level in the tank reach the specified position, at which point the water replenishment pump stops to ensure that the rated working pressure and water level are maintained in the tank at all times.

1. Fully automatic pneumatic water supply fire-fighting equipment: When a fire occurs and the fire hydrant is opened, a fire water column is immediately sprayed out. At the same time, the fire-fighting water stored in the pneumatic tank (10 minutes) is sent into the fire-fighting pipeline network by gas pressure to meet the ten minute fire-fighting flow and pressure.

2. Fully automatic emergency water supply and firefighting equipment: When a fire occurs and the fire hydrant is opened, a fire water column is immediately sprayed out, and the electric contact pressure gauge sends a signal to start the fire pump and supply the required firefighting water. If there is a power outage in the power grid, the main circuit will automatically switch to the backup power source to start the fire pump and ensure the normal operation of the equipment.

3. Fully automatic diaphragm fire-fighting equipment: The working principle is basically the same as that of fully automatic emergency water supply fire-fighting equipment. The diaphragm fire-fighting equipment is equipped with diaphragm capsules, which can avoid the problem of air dissolving in water.

Excellent quality
All precision core components are imported from original brands, ensuring product stability
Strictly follow the IS9001 quality management system standard for production, storage, and transportation
All devices undergo strict pre-sales inspections

Cost-effective
Factory direct sales, no intermediary price difference, unified price, better quality
High output greatly reduces production costs, and the company adopts a profit model of small profits and high sales volume

Shanghai Gaotian Pump solemnly promises to its customers

① The product is accompanied by a certificate of inspection and a user manual to ensure that users can correctly install and use our company's products. Ensure that all products leaving the factory are produced and inspected in accordance with relevant national standards, and any unqualified products will never leave the factory. Ensure strict fulfillment and fulfillment of the three guarantees for products, strictly comply with relevant national regulations on after-sales service for industrial products, and provide a one-year warranty for factory products from the date of shipment. Under the normal operating conditions specified in the product manual, our company will be responsible for ensuring that the product quality is intact within the shelf life.

② If users raise quality objections to our company's products, the company guarantees to provide a solution within 24 hours after receiving the objections. If on-site solutions are required, ensure that professional technical service personnel are dispatched, and ensure that service personnel do not evacuate until quality issues are resolved. Our company archives every product quality issue and handling result reported by users.

Thank you for visiting the Takata Pump website. If you have any questions, you can call our 24-hour sales hotline:

021-57239999

We will wholeheartedly provide you with high-quality service.

Related articles

National standard for non negative pressure variable frequency water supply equipment
What is variable frequency constant pressure water supply equipment?
Selection and precautions for non negative pressure water supply equipment
Precautions for installation and use of variable frequency constant pressure water supply equipment
What are the aspects of regular maintenance for variable frequency constant pressure water supply equipment
Difference in working principle between variable frequency constant pressure water supply equipment and non negative pressure water supply equipment


Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!