Kemu Electronics (Shanghai) Trading Co., Ltd
Home>Products>Automatic refractometer for petroleum products
Automatic refractometer for petroleum products
SH/T 0724 Determination of refractive index and refractive dispersion of liquid hydrocarbons. SH/T 0205 Determination of refractive index and specific
Product details


Automatic refractometer RA-620/RA-600 for petroleum products

The fully automatic refractometer RA-620/RA-600 for petroleum products meets the standard:

GB/T 6488-2008 Determination of refractive index of liquid chemical products (20 ° C).
GB/T 614-2006 Chemical reagents General method for determination of refractive index.
GB/T 5527-2010 Determination of refractive index of animal and vegetable oils and fats.
GB/T 13531.7-2018 General inspection methods for cosmetics - Determination of refractive index.
SH/T 0724-2002 Determination of refractive index and refractive dispersion of liquid hydrocarbons.
SH/T 0205-1992 Determination of refractive index and specific dispersion of electrical insulating liquids.
SH/T 0729-2004 Calculation method for carbon distribution and structural group composition of petroleum fractions (n-d-M method).
NB/SH/T 0838-2010 Determination of polycyclic aromatic hydrocarbons (PCA) content in unused lubricating base oils and asphaltene free petroleum fractions by dimethyl sulfoxide extraction refractive index method.
SN/T 0041-2011 Test method for PONA value of exported naphtha Part 4 Determination of cycloalkanes in saturated hydrocarbon fractions by refractive index method.
MH/T 6114-2017 Determination of refractive index of de icing and anti icing fluids.

ASTM D1218 - 12(2016) Standard Test Method for Refractive Index and Refractive Dispersion of Hydrocarbon Liquids( Test method for refractive index and refractive dispersion of liquid hydrocarbons.
ASTM D1747-09 (2019) Standard Test Method for Refractive Index of Viscous Materials.
ASTM D1807 - 00(2005)e1 Standard Test Methods for Refractive Index and Specific Optical Dispersion of Electrical Insulating Liquids( Test method for refractive index and specific optical divergence of electrically insulating liquids.
ASTM D5006 - 11(2016) Standard Test Method for Measurement of Fuel System Icing Inhibitors (Ether Type) in Aviation Fuels( Test method for measuring fuel system icing inhibitors (ether type) in aviation fuels.

The main features of the fully automatic refractometer RA-620/RA-600 for petroleum products are:

1. Refractometer with touch screen LCD display, displaying refractive index, soluble solids, and concentration.
2. Built in fully automatic temperature control, total reflection measurement, easy operation, and fast measurement speed.
3. Using LED light source does not require replacing the bulb, and the measuring prism is sapphire wear-resistant and corrosion-resistant.
4. Digital refractometer, compliant with GLP standards, automatically stores results, inspection and calibration records.
5. The refractive index and concentration comparison table or calculation formula can be inputted to automatically convert the concentration value of the sample.
7. Standard sample non-volatile cover plate can prevent the impact of volatile samples during testing.
8. It can be connected to an external digital densitometer and various automatic samplers to simultaneously measure density and refractive index.
9. Chinese interface, simple and intuitive operation, high-precision measurement results, and ultra-high cost-effectiveness.

Technical parameters of the fully automatic refractometer RA-620/RA-600 for petroleum products:

form

Fully automatic refractometer

Instrument model

RA-620

RA-600

measuring method

Detection of critical angle of light refraction

light source

LED sodium spectrum D-line (589.3nm)

Measurement project

Refractive index, sugar content, concentration

measuring range

Refractive index (nD)

1.32000~1.58000

1.3200~1.7000

Sugar content (Brix)

0.00~100.00%

Accuracy

Refractive index (nD)

±0.00002

±0.0001

Sugar content (Brix)

±0.014%

±0.1%

Repeatability

Refractive index (nD)

±0.00001

±0.0001

Sugar content (Brix)

±0.007%(<5%), ±0.01%(≧5%)

±0.1%

Resolution

Refractive index (nD)

0.00001

0.0001

Sugar content (Brix)

0.001%(<5%), 0.01%(≧5%)

0.1%

temperature control

5-75 ° C, built-in Peltier temperature control (RA-600 can choose 5-100 ° C)

temperature resolution

0.01°C

0.1°C

Sample size

About 0.2mL

Sample contact material

Prism

sapphire

Sample stand

SUS316 stainless steel

display

4.7-inch color LCD touch screen

Operation method

Touch screen with touch pen

Security

Password protection

Data storage

measuring method

100 methods

measurement result

300 sets of results

Correction record

20 groups

Inspection records

20 groups

External storage

USB drive

Automatic temperature correction

5~75°C

Input the refractive index to a thermometer or polynomial, and automatically convert it to the refractive index at the desired temperature

Automatic concentration conversion

100 sets

Input refractive index to concentration table or polynomial, and automatically convert refractive index to concentration

Interface

LAN: computer

USB: USB flash drive, keyboard, barcode printer, printer

RS-232C: Printer, automatic sample cleaning unit, multi sample automatic sampler

environment condition

1) Temperature: 5~35°C

2) Humidity: Below 85% RH

Power Supply

AC100~240V, 50Hz/60Hz (AC adapter), can be connected to an external rechargeable battery

power

About 20 watts

size

192(W) × 281(D) × 166(H)mm

weight

About 5 kilograms

Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!