Product Overview: This instrument uses Pitot tube parallel constant velocity sampling method to collect particulate matter from fixed pollution source
Product details

Product Overview

This instrument uses Pitot tube parallel constant velocity sampling method to collect particulate matter from fixed pollution source exhaust, uses filtration weighing method to determine the mass of smoke and dust, and uses constant potential electrolysis method to quantitatively determine the composition of flue gas. The newly upgraded control system improves the performance of the instrument, ensures the reliability of the instrument, improves the stability of the system, and enhances the accuracy of control. It is applied to the determination of emission concentration, converted concentration, total emission of particulate matter from various boilers, flues, industrial furnaces and other fixed pollution sources, as well as the determination of equipment dust removal and desulfurization efficiency; Automatic measurement of flue gas dynamic pressure, flue gas static pressure, flow rate, pressure in front of the flow meter, temperature in front of the flow meter, flue gas temperature, moisture content, etc O2、SO2、CO、NO、NO2、CO2Concentration and other parameters.
The product is widely used in environmental protection, testing companies, industrial and mining enterprises (power plants, steel plants, cement plants, sugar factories, paper mills, smelters, ceramic factories, boilers and kilns, as well as aluminum, magnesium, zinc, titanium, silicon, pharmaceutical industries, including fertilizer, chemical, rubber, material factories, etc.), health, labor, safety supervision, military, scientific research, education and other fields.


execution standard

  • GB/T 16157-1996 Sampling Method for Particulate and Gaseous Pollutants in Exhaust from Fixed Pollution Sources
  • HJ/T 48-1999 Technical Conditions for Smoke and Dust Samplers
  • HJ 57-2017 Determination of Sulfur Dioxide in Fixed Source Waste Gas by Potentiometric Electrolysis Method
  • HJ 693-2014 Determination of nitrogen oxides in exhaust gas from fixed sources of pollution - Potentiometric electrolysis method
  • HJ 836-2017 Determination of Low Concentration Particulate Matter in Fixed Source Exhaust Gas by Gravimetric Method
  • HJ 870-2017 Determination of Carbon Dioxide in Waste Gas from Fixed Pollution Sources Non dispersive Infrared Absorption Method
  • JJG 680-2007 Verification Regulations for Smoke and Dust Samplers
  • JJG 968-2002 Verification Regulations for Smoke Analyzer
  • DB13/T 2375-2016 Determination of Low Concentration Particulate Matter in Waste Gas from Fixed Pollution Sources by Weight Method

Product Features

control system
  • Designed with an industrial grade embedded controller, it has strong anti-static capability
  • 5.0-inch touch screen, high brightness display, visible under strong light, wide viewing angle; Thickened resistive touch panel with good anti-interference ability and strong environmental adaptability; The operation interface is simple and friendly, and the data presentation is intuitive
  • Equipped with Chinese input method, it is convenient for users to input information such as sampling location
  • Rich human-machine interface: equipped with RS232, USB and other interfaces, supporting data communication, USB data transfer and output
  • Provide USB interface to export sampling data files and support instrument software upgrades
  • Select Bluetooth high-speed low-noise micro thermal printer, supporting wireless Bluetooth and wired printing dual-mode, easy to grasp real-time data
  • Real time recording of equipment working status data, with power outage memory function during sampling process
  • Multi mode moisture content detection: compatible with both dry wet bulb method and resistance capacitance method measurement modes
  • Capable of synchronous operation of smoke sampling and smoke measurement
  • Equipped with fault self checking function, it can detect instrument functions and prompt faults, facilitating user maintenance and use
  • Equipped with automatic airtightness detection function, it can automatically diagnose the airtightness of the gas path and record it in the file
  • Supports dual functions of smoke sampling and smoke direct reading (optional)

power system

  • Efficient sampling pump, corrosion-resistant, maintenance free continuous operation, adaptable to various working conditions, with overload protection function
  • Microcomputer controlled constant speed tracking sampling, proprietary adjustment method, fast response time; Precision pressure sensors combined with stable flow control can achieve stable tracking of ultra-low flow rates
  • The instrument has a built-in elastic gas volume to improve the stability of sampling flow rate
  • Equipped with anti backflow function, it can prevent the smoke and dust collected after sampling from being sucked out, ensuring the accuracy of sampling data
  • Accurate electronic flowmeter control, real-time monitoring of temperature and pressure, and temperature compensation for flow rate to ensure accuracy

other

  • High performance 5-series gas sensor, with more stable and reliable performance
  • Integrated electrochemical sensor module, can independently select imported sensors according to needs, can simultaneously measure up to 6 gases
  • Gas sensor correction and compensation technology: Smoke measurement has an automatic correction algorithm for gas cross interference, which maximizes the avoidance of the impact of cross interference on measurement results and ensures measurement accuracy
  • Optional lithium battery pack power supply, can simultaneously supply power to the host and low concentration smoke multifunctional sampling tube or resistance capacitance humidity detector, with dual working modes of battery and AC power
  • Pre measurement of working conditions, reducing pipeline and line connections, simplifying on-site instrument connections
  • Working condition measurement supports both wired and wireless communication modes, better meeting complex on-site requirements
  • Optional blank sample sampling bracket with synchronous collection of full program blank samples and automatic generation of blank sample report function
  • Reserved IoT module interface, capable of expanding networking functions
  • The instrument is equipped with built-in electronic tags, which can be used in conjunction with the instrument inventory management platform software to achieve intelligent management of the instrument
  • Sampling files support QR code display function, which can be obtained and saved by scanning with dedicated software

explain:

1. The above content fully complies with the requirements of relevant national standards. Due to product upgrades or discrepancies between pictures and actual machines,

Please refer to the actual machine, this content is for reference only.

2. If your needs deviate from theirs, please callserviceHotline:
Or consult the regional sales representative in detail, thank you!

Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!