BINDER CB160 CO2 incubator
1、 Product Introduction:
1. Temperature range: ambient temperature plus 7 ℃ to 60 ℃
2. Humidity range: up to 95% relative humidity
3. Optional O2 adjustment range: 0.2-20 Vol. -% O2 or 10-95 Vol. -% O2 (version O, GO)
4. Automatic sterilization through hot air at 180 ℃
5. Humidification system for culture dishes with condensation protection
6. CO2 mixed gas nozzle with Venturi effect
7. CO2 sensor using infrared technology that can be sterilized with hot air
8. Display through LCD color monitor
9. Lockable door handle
10. Sealed inner door made of safety glass (ESG)
11. Seamless deep drawn inner cavity made of stainless steel
12. Three perforated shelves made of stainless steel
13. Stackable devices using stacking adapters
14. Fault diagnosis system using optical and sound alarms
15. Computer interface: Ethernet
16. Internal measurement value recording and USB interface
17. Zero voltage alarm contact
2、 Technical parameters:
Product model | CB160-230V1 | CB160-230V-G1 |
CB160- 230V-O1 |
CB160-230V-GO1 | CB160UL-120V1 | CB160UL-120V-G1 | CB160UL-120V-O1 |
CB160UL- 120V-GO1 |
Choose a model | standard | Equipped with a 4-piece detachable inner door | With O2Adjust | With O2Adjustable and 4-piece detachable inner door | standard | Equipped with a 4-piece detachable inner door | With O2Adjust | With O2Adjustable and 4-piece detachable inner door |
Item code | 9040-0092 | 9040-0100 | 9040-0094 | 9040-0102 | 9040-0093 | 9040-0101 | 9040-0095 | 9040-0103 |
measure | ||||||||
Internal volume [L] | 150 | 150 | 150 | 150 | 150 | 150 | 150 | 150 |
Net weight of equipment (unloaded) [kg] | 107 | 108 | 106 | 110 | 107 | 108 | 106 | 110 |
Maximum total load [kg] | 30 | 30 | 30 | 30 | 30 | 30 | 30 | 30 |
Maximum load per partition [kg] | 10 | 10 | 10 | 10 | 10 | 10 | 10 | 10 |
The dimensions of the casing do not include additional components and connectors | ||||||||
Net weight width [mm] | 680 | 680 | 680 | 680 | 680 | 680 | 680 | 680 |
Net weight at height [mm] | 920 | 920 | 920 | 920 | 920 | 920 | 920 | 920 |
Depth net weight [mm] | 715 | 715 | 715 | 715 | 715 | 715 | 715 | 715 |
Wall to side distance [mm] | 50 | 50 | 50 | 50 | 50 | 50 | 50 | 50 |
Wall distance from rear [mm] | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 |
Internal dimensions | ||||||||
Width [mm] | 500 | 500 | 500 | 500 | 500 | 500 | 500 | 500 |
Height [mm] | 600 | 600 | 600 | 600 | 600 | 600 | 600 | 600 |
Depth [mm] | 500 | 500 | 500 | 500 | 500 | 500 | 500 | 500 |
The number of doors | ||||||||
Inner door | 1 | 4 | 1 | 4 | 1 | 4 | 1 | 4 |
Outer door | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 |
Data related to the environment | ||||||||
Energy consumption at 37 ℃ [Wh/h] | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 |
firmware | ||||||||
Number of partitions (hours/maximum) | 3/6 | 2/2 | 3/6 | 2/2 | 3/6 | 2/2 | 3/6 | 2/2 |
Temperature performance data | ||||||||
The temperature range exceeds the indoor temperature by 7 ℃ to [℃] | 60 | 60 | 60 | 60 | 60 | 60 | 60 | 60 |
The temperature deviation is 37 ℃ [± K] | 0.3 | 0.3 | 0.3 | 0.3 | 0.3 | 0.3 | 0.3 | 0.3 |
Temperature fluctuation at 37 ℃ [± K] | 0.1 | 0.1 | 0.1 | 0.1 | 0.1 | 0.1 | 0.1 | 0.1 |
The recovery time after opening the door in 30 seconds is 37 ℃ [min] | 5 | 5 | 5 | 5 | 5 | 5 | 5 | 5 |
Climate performance data | ||||||||
Humidity range [% relative humidity] | 90…95 | 90…95 | 90…95 | 90…95 | 90…95 | 90…95 | 90…95 | 90…95 |
CO2Data | ||||||||
CO2Range [Vol. -% CO]2] | 0…20 | 0…20 | 0…20 | 0…20 | 0…20 | 0…20 | 0…20 | 0…20 |
CO2Measurement technology | IR | IR | IR | IR | IR | IR | IR | IR |
CO2The recovery time after opening the door in 30 seconds is 5 vol. -% CO2[min] | 5 | 5 | 5 | 5 | 5 | 5 | 5 | 5 |
Electrical data | ||||||||
Rated voltage [V] | 200…240 | 200…240 | 200…240 | 200…240 | 100…120 | 100…120 | 100…120 | 100…120 |
Power frequency [Hz] | 50/60 | 50/60 | 50/60 | 50/60 | 50/60 | 50/60 | 50/60 | 50/60 |
Rated power [kW] | 1.3 | 1.3 | 1.3 | 1.3 | 1.3 | 1.3 | 1.3 | 1.3 |
Equipment safety device [A] | 10 | 10 | 10 | 10 | 16 | 16 | 16 | 16 |
Phase (rated voltage) | 1~ | 1~ | 1~ | 1~ | 1~ | 1~ | 1~ | 1~ |
O2 data | ||||||||
Standard O2Adjustment range: O2Range [Vol. -% O]2] | - | - | 0.2…20 | 0.2…10 | - | - | 0.2…20 | 0.2…20 |
Optional O2Adjustment range: O2Range [Vol. -% O]2] | - | - | 10…95 | 10…95 | - | - | 10…95 | 10…95 |
O2The recovery time after opening the door in 30 seconds is 5 vol. -% O2[min] | - | - | 12 | 12 | - | - | 12 | 12 |
1. All technical data is only applicable to standard specifications of unloaded equipment at an ambient temperature of 22 ± 3 ℃ and a power supply voltage fluctuation of ± 10%. Determine temperature data according to BINDER factory standards and DIN 12880:2007, and adapt to the recommended wall gap of 10% of the internal chamber height, width, and depth. For series devices, all data are typical averages. We reserve the right to make technical changes.