Product Introduction
1. Unique dual temperature control slot design, individually controlled, temperature does not affect each other, one machine can be used for multiple purposes, meeting more experimental needs.
2. OLED screen display, refreshing and simple interface, dual time and temperature settings, real-time temperature display, and time decreasing display.
3. The instrument has fast heating speed, uniform heating, accurate temperature control, high stability, and programmable function. Low energy consumption and no noise.
4. Built in temperature deviation calibration function, automatic fault detection and buzzer alarm function.
5. Built in over temperature protection device for safer and more reliable use, extending the service life of the machine.
6. The product design is compact and tight, occupying a small space range, bringing more freedom and convenience.
7. Multiple module options, replacement, easy to clean and disinfect, suitable for various test tubes.
8. The high module sealing sleeve with lid design can achieve a fully enclosed constant temperature of 15/50ml high modules.
9. The heating type can be equipped with an external sensor for more precise and direct temperature control.
model | BTH-100D (Double Heating Type) | BTC-100D (dual cooling type) | BTH-100 (mixed cooling and heating type) |
Temperature Control Range | Room temperature+5 ℃ ~100℃ | -10℃ ~100℃ | Heating: Room temperature+5 ℃ ~100℃ |
Cooling:-10℃ ~100℃ | |||
Temperature Stability @100℃ |
≤±0.5℃ | ≤±0.5℃ | ≤±0.5℃ |
Maximum temperature difference of module @40℃ |
0.3℃ | 0.3℃ | 0.3℃ |
Module temperature uniformity | ≤±0.3℃ | ≤±0.3℃ | ≤±0.3℃ |
Display Accuracy | 0.1℃ | 0.1℃ | 0.1℃ |
heating up time | ≤15min (20℃ to 100℃) | ≤15min (20℃ to 100℃) | ≤15min (20℃ to 100℃) |
maximum temperature | 100℃ | 100℃ | 100℃ |
Cooling time | / | ≤25min (Room temperature drops by 25 ℃) (Tested when the ambient temperature is below 26 ℃) |
≤25min (Room temperature drops by 25 ℃) (Tested when the ambient temperature is below 26 ℃) |
time range | 1min ~99h59min | 1min ~99h59min | 1min ~99h59min |
Input power supply | AC 220V / AC 110V, 50/60Hz | AC 90V ~230V, 50/60Hz | AC 220V / AC 110V, 50/60Hz |
power | 150W | 200W | 170W |
fuse | 250V,2A/4A, Ф5×20 | 250V,2A/4A, Ф5×20 | 250V,2A/4A, Ф5×20 |
External dimensions | W.240 x D.260 x H.168mm | W.240 x D.260 x H.168mm | W.240 x D.260 x H.168mm |
net weight | 2.6kgs | 2.6kgs | 2.6kgs |
model | aperture | Number of test tubes | Maximum capacity |
BT-A | 0.2ml centrifuge tube | 0.2ml x 24 | 8 piece |
BT-B | 0.5ml centrifuge tube | 0.5ml x 12 | 8 piece |
BT-C | 1.5ml centrifuge tube | 1.5ml x 6 | 8 piece |
BT-D | 2.0ml centrifuge tube | 2.0ml x 6 | 8 piece |
BT-E | 0.2ml centrifuge tube | 0.2ml x 96 | Two standard PCR plates can be placed |
BT-F | 15ml centrifuge tube | 15ml x 6 | 4 piece |
BT-G | 50ml centrifuge tube | 50ml x 3 | 4 piece |
BT-H | 1.5ml centrifuge tube | 1.5ml x 6 | 2 pieces |
BT-I | customized | customized | customized |