BasicThe series is sourced from urban tap water and can be conveniently and quickly manufacturedROReverse osmosis waterDIDeionized water, tailored for users who use traditional distilled water machines, enables automatic, fast, and convenient access to high-quality deionized water, completely replacing traditional single distillation methods that are time-consuming, energy consuming, and have low water consumption efficiency(The resistivity is approximately0.2 MΩ.cm)Double steaming(The resistivity is approximately1.5MΩ.cm)Triple distilled water machine(The resistivity is approximately3-4 MΩ.cm)It is an upgraded product of distilled water machines and the basic choice for laboratory water.
existingBasic-RO/Q 2Sub product series, system water production:15、30、45rise/Hour, resistivity>10MΩ.cm, superior toGB6682-2008The first level water standard meets the requirements of the vast majority of chemical and biological experimental water, conventional production process water, and laboratory vessel cleaning water. It can be used as the inlet water for instruments such as ultrapure water systems, high-pressure steam sterilizers, and environmental test chambers
Fully automatic microcomputer control system
LEDThe LCD screen displays the animated working status in real-time throughout the entire process.
The operating status is intuitive and easy to read, with real-time display of flushing, water production, full water, short water, and maintenance status
fully automaticROMembrane anti scaling flushing program
Equipped with startup, water shortage reset, and cumulative water production2Hour by hour3speciesROMembrane anti scaling timing30Instant flushing program, extendedROMembrane lifespan.
System alarm function
Equipped with power on self-test, power-off reset, and over limit operation(continuous6hour)Sound and light alarm functions for water shortage, water leakage, low and high pressure protection, etc.
Spray painted chassis
Ergonomic design, water and electricity separation structure, beautiful and exquisite appearance, eliminate corrosion and rust, ensure the cleanliness of the body, and comply withGLPstandard.
Built in water tank in the system(ITSeries)
Optional built-in12Boosting the pressure water bucket saves laboratory space and makes installation and maintenance more convenient.
portableTDS/Conductivity testing pen
Dry battery design, capable of measuring tap water andROAqueousTDSTotal solid solubility, conductivity, water temperature, and can also be used forDIQualitative measurement of the quality of deionized water.
2、 Technical parameters
name |
Reverse osmosis pure water machine |
||
PRODUCT MODEL |
Basic-RO15(IT) |
Basic-RO30(IT) |
Basic-RO45(IT) |
Pure water production* |
15L/Hour |
30L/Hour |
45L/Hour |
ROReverse osmosis pure water index |
|||
Ion retention rate |
97%-99%(Using new)RODuring the membrane) |
||
Organic interception rate |
>99%WhenMW>200dalton |
||
Particle and bacterial retention rate |
>99% |
||
Raw water requirements |
Urban drinking tap water, water temperature5-45℃, water pressure1.0-4.0Kgf/cm2 |
||
External dimensions/weight |
Length×Width×Height: four hundred and ten×320×420mm; Weight:make an appointment15Kg(ITSeries: Length x Width x Height: four hundred and ten×400×420mm; Weight:make an appointment20Kg) |
||
Electrical requirements |
100-240V,50/60Hz |
||
power |
48W |
72W |
120W |
system configuration |
host(contain1Purification column set)+TDS/Conductivity testing pen+Built in type12Boosting pressure water bucket(IT)+accessory kit |
*The value is affected by different temperatures, inlet water quality, and total pollution of the inlet water.
name |
Deionized pure water machine |
||
PRODUCT MODEL* |
Basic-Q15(IT) |
Basic-Q30(IT) |
Basic-Q45 |
Pure water production** |
15L/Hour |
30L/Hour |
45L/Hour |
Deionized water production |
up to2.0L/Min(When there is water in the water tank) |
||
DIDeionized pure water index |
|||
resistivity(25℃) |
13-17.5MΩ.cm |
||
conductivity |
0.077-0.055μs/cm |
||
bacteria |
<0.01cfu l="">0.01cfu>Optional(0.45+0.1)μmImportPESWhen using terminal filters |
||
particulate(>0.1μm) |
<1>1>Optional(0.45+0.1)μmImportPESWhen using terminal filters |
||
ROReverse osmosis pure water index |
|||
Ion retention rate |
97%-99%(Using new)RODuring the membrane) |
||
Organic interception rate |
>99%WhenMW>200dalton |
||
Particle and bacterial retention rate |
|
>99%WhenMW>200dalton>99% |
|
Raw water requirements |
Urban drinking tap water, water temperature5-45℃, water pressure1.0-4.0Kgf/cm2 |
||
Size and Weight |
Length×Width×Height: four hundred and ten×320×420mm; Weight:make an appointment15Kg(ITSeries: Length x Width x Height: four hundred and ten×400×420mm; Weight:make an appointment20Kg) |
||
Electrical requirements |
100-240V,50/60Hz |
||
power |
48W |
72W |
120W |
system configuration |
host(contain1Purification column set)+TDS/Conductivity testing pen+Built in type12Boosting pressure water bucket(IT)+accessory kit |
* ITThe series is built-in12LPressure bucket.
**The value is affected by different temperatures, inlet water quality, and total pollution of the inlet water.