Technical Parameter
|
specifications |
model |
SC-BDL-10000ADJ
|
SC-BDL-15000ADJ
|
SC-BDL-20000ADJ |
|
short-circuit current |
10000A |
15000A |
20000A |
|
|
Internal dimensions of explosion-proof box |
Independent explosion-proof room or optionalW3000×H3000×D2000mm |
|||
|
Main technologies index |
short-circuit |
Vacuum arc extinguishing high current contact device(0.5mΩ、1mΩ、5mΩ、10mΩ、20mΩ、50mΩ、80mΩ |
||
|
Device internal resistance |
(Multi gear control or selection of other gears) |
|||
|
Resistance gear switching |
Software control, no need to switch wiring terminals, simple and convenient operation |
|||
|
mechanical life |
50one million time |
|||
|
temperature range |
room temperature |
|||
|
software system |
control mode |
Full computer remote control+Industrial remote control |
||
|
Graded control collection |
Voltage, current, and resistance can all be controlled and collected in stages, making it convenient to test different specifications of battery packs and improving testing accuracy to a greater extent. It is fully controlled by software, does not require manual intervention, and is easy to operate; |
|||
|
software |
Professional Short Circuit Measurement and Control System |
|||
|
contrast curve |
Synchronous collection of short-circuit current, voltage, temperature, and time, with four in one curve display |
|||
|
data export |
Access,Excel,txt |
|||
|
acquisition system (Customizable)
|
data type |
electric current |
voltage |
temperature |
|
Range |
0~full scale |
0-1000V |
0---1300℃ |
|
|
precision |
±0.5%FS |
±0.1%FS |
±1℃ |
|
|
resolution |
1A |
0.1V |
0.1℃ |
|
|
Data collection frequency |
≥100Hz(Standard equipment) |
≥1000Hz(Standard equipment) |
||
|
Standard configuration |
Host, resistor box, computer, console, industrial remote control, temperature measurement cable, voltage acquisition cable |
|||
|
selectjoin in marriage |
High definition explosion-proof camera system, automatic fire extinguishing system |
|||
|
Protection alarm device |
Short circuit protection, overload protection, emergency stop, abnormal sound and light alarm |
|||
|
supply voltage |
AC220V,50Hz,1.5kW |
AC220V,50Hz,2.5kW |
||