VIP member
Bottom mounted magnetic flip column level gauge
Bottom mounted magnetic flip column level gauge
Product details
The bottom mounted magnetic flip column level gauge produced by our company is another top mounted (bottom mounted) product developed for centralized control, which has the advantages of clear on-site indication and remote control This product can be widely used for liquid level indication on various towers, tanks, tanks, and spherical containers in industries such as petrochemicals, fertilizers, pharmaceuticals, ships, and military.
Magnetic flap level gauge
Main technical indicators:
Technical requirements for bottom mounted magnetic flip column level gauge
Measurement range: 0-5000mm
Accuracy: ±10mm ±16mm
Flip column diameter: 10mm, 16mm
Nominal pressure: 2.5MPa
Medium density: ≥ 0.7g/cm3 (special requirements can reach 0.45g/cm3)
Medium temperature:- 20~+350℃
Wetting Material: Stainless Steel 304/316/316L and PP Material
Medium viscosity: ≤ 2.0Pa.s
Environmental vibration: frequency ≤ 25Hz, amplitude ≤ 0.5mm
Follow speed: ≤ 0.05m/s
Flange standard: HG20592~20635-97
Alarm and remote transmission device: The technical parameters are the same as those of the UHZ-25 series.
Working principle of bottom mounted magnetic flip column level gauge:
The bottom mounted magnetic flip column level gauge consists of a body (composed of upper and lower conduits), a flip plate box (composed of red and white dual color magnetic flip plates), a float (composed of magnets, top rods, and floats), and a level transmitter. Its structure is shown in the figure. The working principle is that the float inside the container (developed according to different media and pressures) floats up and down in the lower conduit with the change of liquid level height, and the magnet moves up and down in the upper conduit through the top rod, causing the flipping plate outside the body to flip and indicate the liquid level height with red and white colors. At the same time, the liquid level transmitter transmits the liquid level signal to the control center for liquid level indication and control, and can also be centrally monitored through a computer.
1. When the side opening of the container is not suitable and there is little space around the container, this type of liquid level gauge can be installed on the upper or lower part of the container
2. Suitable for liquid media with high viscosity
3. The viewing direction of the monitor can be changed arbitrarily
4. Other features are the same as those of UFZ.
Selection instructions:
1. The nominal pressure of anti-corrosion type is ≤ 1.0MPa.
2. There is a certain blind spot in the liquid level gauge, so compensation for the blind spot value should be added when reading the liquid level height (when our liquid level gauge leaves the factory, the zero position of the scale has been moved to the actual value).
3. The measuring range of the liquid level gauge should not exceed 5 meters, otherwise it will affect the stability, reliability, and fastness of the liquid level gauge.
4. Install the connecting flange, and refer to the commonly used protrusion size reference (HG21592-97) for manufacturing this level gauge at the factory.
Installation, use, and maintenance:
1. The protective conduit and main conduit of the liquid level gauge must be kept vertical
2. The connecting rod cannot bend and must be inserted straight
3. After installation, the flip column of the monitor needs to be guided once with magnetic steel to display white above zero and red below zero.