Shanghai Fuxin Pump Valve Co., Ltd
Home>Products>Brine pump
Brine pump
IHF Frozen Salt Water Pump - Using a metal shell lined with perfluoroethylene propylene (F46), the pump cover, impeller, and shaft sleeve are all made
Product details

IHF saltwater pump - using a metal shell lined with perfluoroethylene propylene(F46)The pump cover, impeller, and shaft sleeve are all made of metal inserts wrapped in fluoroplastic and sintered as a whole. They have the characteristics of no cracking, no aging, no deformation, resistance to strong acids and alkalis, and resistance to strong oxidants. They are the preferred corrosion-resistant pump for transporting highly corrosive solutions.

applications

shipbuilding industry,Chemical industry,Pharmaceutical industry,Metallurgical Industry,Power industry,Oil industry,paper industry,Food industry,Water industry,other

general outline Describe:
IHFFluorine lined plastic alloy centrifugal pump (abbreviated as)IHFFluorine lined centrifugal pumps are designed and manufactured according to international standards and combined with non-metallic pump processes. The pump body adopts a metal shell lined with perfluoroalkoxy(F46)The pump cover, impeller, and shaft sleeve are all made of metal inserts wrapped in fluoroplastic and sintered as a whole. The shaft seal adopts advanced external corrugated pipe mechanical seal, and the static ring is selected99.9%Aluminum oxide ceramic (or silicon nitride), with PTFE filling material for the moving ring, has excellent corrosion resistance, wear resistance, and sealing performance. The inlet and outlet of the pump are reinforced with cast steel bodies to enhance the pressure resistance of the pump. Actual use shows that the pump has the advantages of corrosion resistance, wear resistance, high temperature resistance, anti-aging, high mechanical strength, smooth operation, advanced and reasonable structure, strict and reliable sealing performance, easy disassembly and maintenance, and long service life. Applicable temperature:-60~100When the usage temperature exceeds120At that time, the pump impeller needs to be made of high-temperature resistant materials. Suitable for continuous transportation of high-risk liquid chemical media such as strong acids, strong bases, organic solvents, and strong oxidants of any concentration, when conveying solid particle content5%When dealing with corrosive liquid media on both sides, it is necessary to provide corrosion-resistant and wear-resistant mechanical seals.

Purpose:
Fluorine lined centrifugal pumps are widely used in acid pickling and painting processes in automotive manufacturing; Electrolyte transportation in non-ferrous metal smelting; The process flow of chlorine water, wastewater treatment, and acid addition in the ion exchange membrane caustic soda project.

Design features:
IHFThe fluorine lined centrifugal pump is designed according to international standards. The pump body is made of a metal shell lined with fluoroplastic, and the impeller and pump cover are made of metal inserts wrapped in fluoroplastic alloy compression molding. The shaft seal adopts advanced external corrugated pipe mechanical seal, and the static ring is selected99.9%Aluminum oxide ceramic, with PTFE filling material for the moving ring (or other materials specially matched according to special working conditions), is characterized by good corrosion resistance, wear resistance, and sealing performance.

Temperature-60~100

Table 1 (n=2900r/min) Model Table:

model

internet traffic

lift

efficiency

npsh

Import * Export

rotational speed

Motor Power

Overall quality

m

%

m

mm

r/min

kw

kg

IHF25-20-125

1

20

25

2.5

25×20

2900

1.1

70

*3.6

20

32

5.5

18

46

IHF25-20-160

1

32

20

2.5

25×20

2900

2.2

110

*3.6

32

25

6

28

30




IHF25-20-200

1

50

15

2.5

25×20

2900

3

140

*3.6

50

22

5.5

48

25

IHF25-20-250

2

80

12

2.5

25×20

2900

7.5

225

*3.6

80

18

5.5

78

26

IHF32-20-125

2

20.5

25

2.5

25×20

2900

1.1

70

*3.6

20

32

5.5

18

46

IHF40-25-160

*6.3

32

30

3

40×25

2900

3

124

8

32

31

10

30

32

IHF40-25-200

*6.3

50

20

3

40×25

2900

5.5

170

8

50

23

10

48

30

IHF40-32-250

*6.3

80

20

5

40×32

2900

11

255

8

80

24

12

78

34

IHF50-32-125

7

22

47

3.2

50×32

2900

2.2

110

*12.5

20

52

15

16

50

IHF50-32-160

7

33

35

3.2

50×32

2900

4

135

*12.5

32

47

15

30

47

IHF50-32-200

7

51

28

3.2

50×32

2900

7.5

180

*12.5

50

40

15

49

48

IHF50-32-250

7

80

21

5

50×32

2900

11

255

*12.5

80

34

15

77

38

IHF65-50-125

15

22

46

3.5

65×50

2900

3

135

*25

20

61

35

16

67

IHF65-50-160

15

33

45

3.5

65×50

2900

5.5

155

*25

32

56

35

30

65

IHF65-40-200

15

52

35

3.5

65×50

2900

11

210

*25

50

51

35

46

48

IHF65-40-250

15

82

33

3.5

65×50

2900

18.5

360

*25

80

48

35

72

50

IHF80-65-125

35

22

52

4

80×65

2900

5.5

195

*50

20

65

60

18

70

IHF80-65-160

35

33

60

4

80×65

2900

11

228

*50

32

64

60

27

53

IHF80-50-200

35

52

55

4

80×50

2900

15

250

*50

50

63

60

45

55

IHF80-50-250

35

82

48

4.5

80×50

2900

30

480

*50

80

56

60

72

50

IHF100-80-125

65

22

62

4.5

100×80

2900

11

245

*100

20

65

120

17

68

IHF100-80-160

65

35

65

5

100×80

2900

15

250

*100

32

70

110

26

65

IHF100-65-200

65

51

62

5

100×65

2900

30

480

*100

50

68

120

43

56

IHF100-65-250

65

82

60

5

100×65

2900

45

550

*100

80

65

120

65

70

IHF125-100-160

100

38

57

5

125×80

2900

30

460

*160

32

64

180

26

52

IHF125-100-200

120

55

63

6

125×100

2900

45

660

*200

50

65

220

45

62

IHF125-100-250

120

86

54

6

125×100

2900

75

850

*200

80

68

210

65

61

Note:1*For standard specifications;Try to choose parameters that are the same or similar to those in this table. If they are not within the scope of this table, our factory will improve the impeller to achieve this.
2
When the flow rate at the operating point is too low, a reflux pipe should be connected to the outlet.

Table 2(n=1450r/min)Model Table:

model

internet traffic

lift

efficiency

npsh

Import * Export

rotational speed

Motor Power

m

%

m

mm

r/min

kw

IHF40-25-250

*3

20

15

5

40×32

1450

1.5

4

20

20

6

19.5

30

IHF50-32-125

3.5

4.5

40

3.2

50×32

1450

0.55

*6.3

5

45

7.5

4

42

IHF50-32-160

3.5

9

30

3.2

50×32

1450

0.55

*6.3

8

40

7.5

7.5

40

IHF50-32-200

3.5

12.8

22

3.2

50×32

1450

1.1

*6.3

12.5

33

7.5

12.3

40

IHF50-32-250

3.5

20

15

5

50×32

1450

1.5

*6.3

20

30

7.5

19.3

32

IHF65-50-125

7.5

3.8

40

3.5

65×50

1450

0.55

*12.5

5

55

17.5

4

61

IHF65-50-160

7.5

8.8

40

3.5

65×50

1450

1.1

*12.5

8

51

17.5

7.5

60

IHF65-40-200

7.5

13

30

3.5

65×40

1450

1.5

*12.5

12.5

46

17.5

11.5

42

IHF65-40-250

7.5

20.5

28

3.5

65×40

1450

3

*12.5

20

43

17.5

18

45

IHF80-65-125

17.5

5.5

50

4

80×65

1450

1.1

*25

5

64

30

4.5

68

IHF80-65-160

17.5

8.3

58

4

80×65

1450

1.5

*25

8

62

30

6.8

50

IHF80-50-200

17.5

13

48

4

80×50

1450

2.2

*25

12.5

57

30

11.3

48

IHF80-50-250

17.5

20.5

43

4.5

80×50

1450

5.5

*25

20

51

30

11.3

45

IHF100-80-125

32.5

5.5

60

4.5

100×80

1450

1.5

*50

5

64

60

4.3

65

IHF100-80-160

32.5

8.8

62

5

100×80

1450

2.2

*50

8

69

55

6.5

62

IHF100-65-200

32.5

12.8

62

5

100×65

1450

5.5

*50

12.5

68

60

10.8

56

IHF100-65-250

32.5

20.5

60

5

100×65

1450

5.5

*50

20

65

60

16.3

70

IHF125-80-160

50

9.5

55

5

125×80

1450

5.5

*80

8

62

90

6.5

50

IHF125-100-200

60

13.8

60

6

125×100

1450

11

*100

12.5

64

110

11.3

60

IHF125-100-250

60

21

53

6

125×100

1450

15

*100

20

69

120

19

71

IHF150-125-250

120

22

60

5

150×125

1450

22

*200

20

65

240

18

64

IHF150-125-315

120

35

54

5

150×125

1450

45

*200

32

63

240

30

62

IHF150-125-400

120

55

50

5.5

150×125

1450

75

*200

50

62

240

47

62

IHF200-150-250

240

22

60

5.5

200×150

1450

45

*400

20

68

480

17

62

IHF200-150-315

240

36

55

5.5

200×150

1450

75

*400

32

64

480

29

63

IHF200-150-400

240

55

52

6

200×150

1450

110

*400

50

64

480

46

64

Note:1*For standard specifications;Try to choose parameters that are the same or similar to those in this table. If they are not within the scope of this table, our factory will improve the impeller to achieve this.
2
When the flow rate at the operating point is too low, a reflux pipe should be connected to the outlet.


Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!