CL420 Clamp Process Table
Product details

CL420 Clamp Process Table

Click to enlarge
Product Model:
Product quotation:
Product Features:
CL120 clamp ammeter, CL130 clamp ammeter, CL135 clamp ammeter, CL150 clamp ammeter, CL155 clamp ammeter
CL220 clamp ammeter, CL235 clamp ammeter, CL250 clamp ammeter, CL255 clamp ammeter
CL320 clamp ammeter, CL340 clamp ammeter, CL345 clamp ammeter, CL360 clamp ammeter
CL420 Clamp Process Table
Previous product: UT75AUT75A digital regulator
Next product: CA700-E-01-U1-P1 pressure calibrator
CL420 Clamp Process TableDetailed information:

CL420 clamp type process table:
Perform a safety current check of 4~20mA using a CL420 clamp type process meter without disconnecting the loop. In addition, data can be easily recorded and monitored through the output function.

0.2% accuracy, 0.01mA resolution
Dual display
LED flashlight with backlit display.
Provide analog output

model CL420
Measurable conductor diameter The largest diameter is 6mm
DC current Range and Resolution [Measurement Range] Measurement accuracy (* 1)
20.00 mA [0.00 to±21.49mA]
100.0 mA [±21.0 to ±126.0mA]
±(0.2%rdg+5dgt) (*2)
±(1.0%rdg+5dgt)
DC voltage output 20.00 mA [0.0 to±214.9mV]
100.0 mA [±210 to±1260mV]
(DCA Accuracy)+(±0.5mV)
(DCA Accuracy)+(±3mV)
display 4-digit LCD digital display
response time About 1.5 seconds (2.5 seconds when cross range)
range switching Auto Range
Working temperature and humidity -10? C to +50? C 80% RH or below (non condensing)
safety standards EN61010-1, EN61010-2-030, EN61010-2-032
Capable of withstanding voltage 2.21kV AC for 5 seconds (between the movement and the casing)
power supply 4 AA alkaline batteries (1.5V LR6)
battery life About 60 hours with backlight off and LEC light off
Other functions Data retention, zero adjustment function, automatic shutdown
LED flashlight, backlight display, luminous panel
External dimensions and weight 61 (W) x 111 (H) x 40 (D) mm
About 290g (including battery)
Standard Appendix Operation manual, battery, soft pack (93045)

(* 1) Is the temperature 23? C ±5? C, When the humidity is between 45% and 75% RH
Measurement accuracy: ± (reading percentage+number)
Accuracy condition: After starting up, open and close the clamp type sensor and perform zero position adjustment.
The guaranteed accuracy of the 20mA range is the average of 5 measurements.
Yokogawa, Japanclamp meter
CL100 series clamp type ammeter:

CL120 clamp ammeterCL130 clamp ammeterCL135 clamp ammeterCL150 clamp ammeterCL155 clamp ammeter
CL200 series clamp type ammeter:
CL220 clamp ammeterCL235 clamp ammeterCL250 clamp type ammeterCL255 clamp ammeter
CL300 series clamp type ammeter:
CL320 clamp type ammeterCL340 clamp type ammeterCL345 clamp type ammeterCL360 clamp type ammeter

Leakage current clamp:
96001 current clamp30031 leakage current clamp meter30031A leakage current clamp type meter30022A leakage current clamp type meter
Portable calibrator
CA11E current and voltage calibratorCA12E temperature calibratorCA13 frequency calibrator
CA51 process calibratorCA71 process calibratorCA150 multifunctional calibratorCA450 process calibrator, CA700 pressure calibrator

Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!