Envent's CO2 analyzer is designed to be simple and reliable, using dual beam technology,

Good accuracy and stability

application

In the quality monitoring and optimization control of natural gas, CO2 is an indicator that needs to be measured at all times, and the measurement range can range from 0-5% to 0-30% depending on the application. Some chemical processes for hydrogen sulfide removal are fine tuned by adding as much CO2 as possible to achieve better values without exceeding the usual pipeline limit of 2-4%. CO2 is also a byproduct of combustion and needs to be quantified.

characteristic

Ø True dual beam technology

Long term stability

Low power consumption

Ø Alarm

Backlight, 16 characters, dual line display

Ø 4-20 mA output

performance

The M90 dual path infrared CO2 analyzer can continuously measure and calibrate the measurement errors formed by the first generation single path infrared detector in the short or long term. The analyzer is designed to be compact, with a power consumption of less than 2W, and can provide linear analog or digital signal output. The adjustable output control contact signal is optional. This analyzer has a high cost performance ratio and can be used for Class 1, Division 1 GroupsC&D hazardous area, standard range is 0-20% CO2, other ranges can be set as needed.

technical parameter

Explosion proof gradeClass 1, Div1 Grps C & D

Operating principleDual optical path, non dispersive infrared (NDIR)

detectorSapphire window sealed with glass powder

Sensing unit pressure2 PSI (13.8 KPa) gauge pressure

Measurement range0-20% CO2 (other ranges can be set as needed)

Repeatability± 0.1 %CO2

DriftingLess than 2.5% of the reading per year

accuracyWhen calibrating the temperature, take the readingofReading at any temperature with ± 3% or 0.1% CO2+5% or 0.1% CO2

Preheating timeLess than 5 minutes

Operating temperature10-50℃

Operating humiditySensor: 0-100% RH (non condensing) electronic unit: 0-90% RH (non condensing)

Storage temperature–20–60

Storage humidity0-90% RH (non condensing)

Analog outputIsolation 4-20 mA

Digital interfaceRS485&RS232

power supply24V/DC, 5W (standard) 12V/DC (optional)

Light source lifespanAt least 10 years

Alarm outputTwo solid-state drives, 2 A, maximum 30 V/DC

Standard Sample Processing SystemBuilt in filter maximum (1500 PSI), stainless steel single-stage regulator maximum (3000 PSI), flow meter maximum (100 PSI)