Beijing Qixing Huachuang Flow Meter Co., Ltd
Home>Products>CS230 Mass Flow Controller&Flow Meter
Firm Information
  • Transaction Level
    VIP member
  • Contact
  • Phone
  • Address
    No. 8 Wenchang Avenue, Beijing Economic and Technological Development Zone (Postal Code: 100176)
Contact Now
CS230 Mass Flow Controller&Flow Meter
The CS230 product is a medium to high flow product developed by Seven Star Flow Meter, with a maximum flow rate of 300SLM nitrogen and the ability to
Product details

advantage

Can meet the wide range flow meter needs of customers, suitable for measuring ranges from medium flow (50slcm) to high flow (300slm).
The accuracy adopts set point precision, and the precision of high-end products can reach ± 1.0% S.P., with a response time of ≤ 2sec.
The CS230 series products support dual power supplies ranging from ± 8V to ± 16V+ 14V~+28V single power supply; Digital, analog input/output.
The CS230 series products adopt precise tubular diversion technology and new electromagnetic valve control technology. The electromagnetic valve control current can reach over 300ma, meeting the control of high flow gas products. The maximum range of the product can reach 300slm nitrogen gas.
The product has multiple RS485 and DeviceNet communication methods.

Technical Parameter

CS230

model

CS230A

Valve type

normally closed

not have

Flow specification (N2)

(50,100,150,200,250,300) SLM

accuracy

±1.0% S.P. (≥35% F.S.) ±0.35% F.S.(<35% F.S.)

linear

±0.5% F.S.

repeatability

±0.2% F.S.

response time

≤ 2sec

Range of working pressure difference

0.15-0.35MPa 50SLM ≤ full-scale flow rate (N2) < 150SLM
0.20~0.35MPa 150 SLM ≤ full-scale flow (N2) ≤ 250SLM
0.25~0.40MPa 250 SLM < full-scale flow rate (N2) ≤ 300SLM

50~100SLM:< 0.02MPa
> 100SLM:< 0.05MPa

temperature coefficient

Zero point: ≤ ±0.05% F.S./℃; During adjustment: ≤ ±0.1% F.S./℃

Maximum working pressure

1 MPa

pressure resistance

3 MPa (435pisg)

Leakage rate

1×10-9atm·cc/s He

Sealing material

Fluororubber; chloroprene rubber

Ambient Temperature

(5~45)℃

Input signal

Number: RS485 or DeviceNetTM or ProfiBus
Simulation: (0-5) VDC or (4-20) mA

not have

output signal

Number: RS485 or DeviceNetTM or ProfiBus
Simulation: (0-5) VDC or (4-20) mA

drift

< 0.6% F.S./year without zero point correction

power supply

± 8 to ± 16 VDC (bipolar) or+14 to+28VDC (unipolar)

surface chemical composition

normal

Standard joint form

Compression Fittingφ6; Compression Fitting1/4´´; (Select when flow rate ≤ 60SLM);
Compression Fitting with a diameter of 8mm (selected when the flow rate is ≤ 200SLM);
Compression Fitting φ10mm; Compression Fitting 3/8´´; Compression Fitting 1/2´´; VCR 1/2´´;

Form of power connector

D-type 9-pin male connector; D-type 15 pin male connector; DeviceNet connector; ProfiBus connector

weight

2.6 Kg

1.5 Kg

Scan the QR code and use your phone to check
Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!