Chemical wastewater tank level gauge
Chemical wastewater tank level gauge
Product details
Chemical wastewater tank level gaugeSpecification
1Chemical wastewater tank level gaugeRange (mm): 300-19000
2. Medium density (g/cm3): 0.51090-2
3Chemical wastewater tank level gaugeMedium viscosity: ≤ 0.0203Pa. S
4. Working temperature ℃:- 40~350
5. Pressure rating (MPa): ≤ 32
6. Measurement accuracy (mm): ≤± 10
7. Installation methods: side mounted, top mounted, bottom mounted

9. Explosion proof level: ib Ⅱ CT4 (intrinsic safety type), d Ⅱ BT4 (explosion-proof type)
10. Transmission mode: 4-20mA or switch quantity
11. Interface flange: PN4.0 DN25 HG20593 (side mounted)
PN1.0 DN100 HG20593 (top mounted, bottom mounted), can be specially customized according to user needs.
Note: When the installation of the level gauge is affected by the environment and the spatial position L1<300 is ordered, it should be clearly stated.
Technical Parameter
Measurement range: 300~12500mm
Accuracy: Indicating ± 10mm
Measurement principles: buoyancy principle, magnetic coupling sensing technology


Measurement medium: various liquids and corrosive, flammable and explosive liquid media
Output format: on-site display, alarm, transmitter output
Work pressure: ≤ 6.3Mpa
Medium temperature: ≤ 450℃
Medium density: ≥ 0.45g/cm3
Medium viscosity: ≤ 0.15pa·s
Explosion proof grade: Exd Ⅱ BT6.ExiacT6
Protection level: IP66
Material: Various grades of stainless steel, PVC, etc
Connection method: flange DN20, DN25 (loose fitting)
Installation methods: side mounted, top mounted
Composed of the main body, flip box (composed of red and white dual color magnetic flip plates), float, flange cover, etc., it is used for measuring the liquid level of various liquid containers.Chemical wastewater tank level gaugeIt can be used for on-site or remote display and control of liquid level in high-temperature, explosion-proof, anti-corrosion, food and beverage, and other occasions. UHZ seriesChemical wastewater tank level gaugeIt can achieve high sealing, leak prevention, and safe and reliable measurement of liquid level under high temperature, high pressure, high viscosity, and strong corrosive conditions. The entire measurement process has no blind spots, eye-catching display, intuitive readings, and a large measurement range. Equipped with liquid level alarm and control switch, it can realize upper and lower limit alarm and control of liquid level or boundary. Equipped with liquid level transmitter, it can adjust the liquid level. The boundary signal is converted into a standard signal of 4-20mADC in a two-wire system, enabling remote detection, indication, recording, and control. UHZ seriesChemical wastewater tank level gaugeWidely used for liquid level measurement and control in the production processes of industries such as electricity, petroleum, chemical, metallurgy, environmental protection, shipbuilding, construction, and food.
Chemical wastewater tank level gauge
Proper assembly, use, and maintenance
1. Magnetic substances are not allowed to approach around the body, and iron wire fixation is prohibited, otherwise it will affectChemical wastewater tank level gaugeNormal work;
2. When users use heat tracing pipelines themselves, non-magnetic materials such as copper pipes must be selected. The heat tracing temperature is determined based on the condition of the medium;
3. Installation must be vertical,Chemical wastewater tank level gaugeA ball valve should be installed between the container inlet pipe for easy maintenance and cleaning;
4. The medium should not contain solid impurities or magnetic substances to avoid jamming the float;
5. Before use, use a calibrated magnetic steel to place the small balls below zero position in red and the other balls in white;
6. Open the bottom flange and install the magnetic float (note: the heavy end with the magnetic end is facing upwards and cannot be inverted);
8. According to the condition of the medium, the main pipe should be cleaned irregularly to remove impurities;
9. For level gauges that exceed a certain length (ordinary type>3 meters, anti-corrosion type>2 meters), it is necessary to add a middle reinforcement flange or ear hook as a fixed support to increase strength and overcome its own weight;
10. The installation location should avoid or be far away from the inlet and outlet of the material medium to prevent rapid changes in the local area of the material fluid, which may affect the accuracy of liquid level measurement;
11. When equipped with remote transmission instruments, the following measures should be taken:
(1) The remote transmission supporting instruments should be tightly attached to the main pipe of the liquid level gauge and fixed with stainless steel clamps (iron is prohibited);
(2) The sensing surface on the remote transmission supporting instrument should face and be closely attached to the main tube;
(3) The zero position of the remote transmission supporting instrument should be on the same horizontal line as the zero position indication of the liquid level gauge;
(4) The connection between the remote transmission supporting instrument and the display instrument or industrial control computer is best laid separately in a protective tube or with a shielded two core cable;
(5) After the wiring holes of the junction box are laid, it is required to be well sealed to prevent rainwater, moisture, etc. from entering and causing the remote transmission supporting instruments to not work properly. The junction box should be promptly covered after maintenance or debugging is completed.

Chemical wastewater tank level gaugeClassification and Applicable Scenarios:
1. Ordinary type: suitable for low, medium, and high pressure applications without special anti-corrosion requirements.
2. Vacuum type: suitable for ultra-low, ultra-high temperature, low, medium, high pressure, and no special anti-corrosion requirements.
3. Frost proof type: suitable for low temperature, low, medium, high pressure, and occasions without special anti-corrosion requirements.
4Chemical wastewater tank level gaugeUnderground type: suitable for underground or top perforated storage tanks, where the medium does not move much.
5. Jacket type: suitable for situations that require insulation or cooling, low, medium, and high pressure, and no special anti-corrosion requirements.
6. Inner lining type: PTFE or other lining, suitable for low, medium, and high pressure applications with special anti-corrosion requirements.
7. Anti corrosion type: made of PP or PVC material, suitable for corrosion resistant applications at room temperature and atmospheric pressure.
Working principle
The flip box outside the main body is driven by the float inside the main body (with a directional magnetic source, developed according to different media and pressures) to flip and display red and white colors, and indicate different liquid level heights with the movement of the float. There is a prominent scale on the left side of the indicator to make the liquid level indication clearer.
Chemical wastewater tank level gaugeComposed of the main body, flip box (composed of red and white dual color magnetic flip plates), float, flange cover, etc., it is used for measuring the liquid level of various liquid containers.Chemical wastewater tank level gaugeIt can be used for on-site or remote display and control of liquid level in high-temperature, explosion-proof, anti-corrosion, food and beverage, and other occasions. The UHZ series products can achieve high sealing, leak prevention, and safe and reliable measurement of liquid level under high temperature, high pressure, high viscosity, and strong corrosive conditions. The entire measurement process has no blind spots, eye-catching display, intuitive reading, and a large measurement range. Equipped with liquid level alarm and control switch, it can realize upper and lower limit alarm and control of liquid level or boundary. With the system, the liquid level can be adjusted.Chemical wastewater tank level gaugeThe boundary signal is converted into a standard signal of 4-20mADC in a two-wire system, enabling remote detection, indication, recording, and control. UHZ seriesChemical wastewater tank level gaugeWidely used for liquid level measurement and control in the production processes of industries such as electricity, petroleum, chemical, metallurgy, environmental protection, shipbuilding, construction, and food.
Chemical wastewater tank level gaugeProduct Selection Table
model Code name Explanation
JKM- □- □- □- JKM remote transmission magnetic flap level gauge
function A
B
Liquid level (can be omitted)
interface
Display mode G
H
J
K
Top mounted flip panel (can be omitted)
Bottom mounted flip board
Top mounted flip column
Bottom mounted flip column
structural style R
T
V
Ordinary (can be omitted)
jacket
frost prevention
pressure Mpa
Usage temperature B
C
D
Low temperature -40 ℃ -150 ℃
Room temperature -20 ℃ -150 ℃ (can be omitted)
High temperature 0 ℃ -350 ℃
Connecting flange R
S
T
X
DN100 (according to the same pressure standard)
DN125 (according to the same pressure standard)
DN150 (according to the same pressure standard)
other
length mm
Medium density g/cm3
material P
V
F
G
H
I
R
S
T
X
PP
PVC
Stainless steel lined with PTFE
Stainless steel lined with PTFE
Stainless steel lining PP
Stainless steel lined with PVC
304 (can be omitted)
321
316L
other
control A
B
C
D
X
None (can be omitted)
Upper limit (contact 24V100A)
Lower limit (contact 24V100A)
Upper and lower limits (contact 24V100A)
other
call the police A
B
C
D
X
None (can be omitted)
Upper limit (contact 24V100A)
Lower limit (contact 24V100A)
Upper and lower limits (contact 24V100A)
other
explosion-proof 6
7
8
Ordinary type (can be omitted)
Intrinsically safe type
Explosion proof type

Chemical wastewater tank level gaugeInstallation form and content Side mounted
Installation spacing (measurement range) 500,800,1100,1400,1700,2000,2500,3000mm
Working pressure 0.6,1.6,2.5,4.0MPa
Medium density ≥ 0.76g/cm 3
medium temperature -40 ℃ ~100 ℃
ambient temperature -40 ℃ ~+70 ℃
Indication error ± 10mm
Viscosity ≤ 1st(10 - 4 m/s)
Upper and lower limit switch output 1. Control sensitivity: 10mm
2. Output contact capacity: AC220V2A
3. Contact life: 5 × 10 4
Continuous display of electric remote transmission 1. Accuracy: ± 1.5%
2. Output load: 750
3. Output signal: 0~10mA output, 220VAC power supply
4~20mA output, 24VDC two-wire system
4. Explosion proof feature ia Ⅱ CT4 intrinsic safety type
▲ Correct installation and debugging of the product
1. After the user's product arrives, the packaging quality of the product should be checked first. The packaging box should be intact and clearly marked. If there is obvious damage to the packaging, the problem and responsibility should be identified in a timely manner. If there is no packaging quality problem, the product can be unpacked and taken out.
2. If necessary, simple inspections can be conducted on the instruments
Remove the float chamber flange and install the float in the upward direction of the arrow into the float chamber. Reinstall the float chamber flange, paying attention to installing the sealing gasket and tightening it evenly. Block the lower connecting flange and slowly inject water from the upper flange mouth. The indicator should have a liquid level indication and the action should be sensitive without jumping. The instrument is normal. If the indicator fails to track the indication, a spare tool magnetic steel can be used to lift the display flip column and couple it with the magnetic float in the float chamber, or magnetic steel can be used to attract the flip column from top to bottom and from bottom to top to indicate correctly.
3. The liquid level gauge should be installed vertically as required in a location that is easy for the process operator to observe and operate. The flange joint surface should be sealed with a gasket, and all fasteners and sealing surfaces should be checked and tightened.
4. The liquid level gauge installed on the pressure vessel should undergo pressure testing together with the vessel according to relevant regulations, or undergo a water pressure test at 1.25 times the working pressure and an air tightness test at 1.05 times the working pressure. After confirming that there is no leakage, it can be put into use.
5. Equipped with alarm switchChemical wastewater tank level gaugeBefore leaving the factory, according to the working pressure and medium density required by the user's order, the float is prepared and calibrated. When using the instrument, it generally does not need to be debugged. If a small deviation is found or precise calibration is required during actual use, the display position can be fine tuned to solve the problem.
6. Adjustment method for alarm points: Place the alarm switch at the desired alarm point, move the magnetic steel up and down at the alarm point, and use a multimeter to check if the alarm point is activated. If there is an error in position, move the alarm switch up and down accordingly until it is accurate.
7. Debugging method of transmitter: Place the magnetic steel at the zero position of the sensor, close the reed switch at the bottom with the highest resistance, adjust the "zero point" potentiometer to output 4mA, and place the magnetic steel at the high range of the sensor, adjust the "range" potentiometer to output 20mA.
8. When disassembling explosion-proof transmitters or alarm switches, the power should be cut off first.
▲ Product maintenance and upkeep
1. For the tested medium containing impurities or viscous substances, the float should be cleaned regularly to prevent it from getting stuck. When disassembling and assembling the float, special attention should be paid to the direction of the float. If the float is installed in the wrong direction, the instrument will not work properly.
2. In order to avoid affecting the rotation and observation of the flip column, the surface of the liquid level gauge should be cleaned regularly to prevent excessive dirt and dust on its surface area.
3. Handle the liquid level gauge with care during transportation, do not invert it, and prevent it from being exposed to rain, sunlight, and strong shock and vibration.
4. When the cylinder has a certain deflection due to being too long, efforts should be made to provide appropriate support for the cylinder.
▲ Product ordering instructions
1. Please specify the model specifications, measurement range, installation height, medium density, medium temperature, and working pressure when placing an order.
2. If users use JB and HG flanges or other specifications of flanges, we can provide them specifically, and our personnel will assist you in selecting or designing special products for you.
3. When users order explosion-proof products, if safety barriers are required, they should be specifically noted
4. After receiving the shipment, please open the box for inspection in a timely manner, check the attachments and materials listed on the installation packing list, and address any issues that may arise
Please contact the business department of our factory in a timely manner for any issues to be resolved as soon as possible.
5. Users must provide their own matching flanges, gaskets, and other connecting components according to the table below.
Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!