Shanghai Chuanshuo Automation Technology Co., Ltd
Home>Products>Chuanshuo DYDT eddy current vibration transmitter
Firm Information
  • Transaction Level
    VIP member
  • Contact
  • Phone
    18149778686
  • Address
    206 Peikun Road, Minhang District, Shanghai
Contact Now
Chuanshuo DYDT eddy current vibration transmitter
Chuanshuo DYDT eddy current vibration transmitter
Product details

Basic parameters

Measurement range:

0-800um (amplitude)

Measurement accuracy:

1%

Place of Origin:

Shanghai

Power Supply:

direct-current

Protection level:

IP67

Type:

Inductive pressure transmitter

authentication:

ISO9001-2000

Weight:

450g

Brand:

Chuan Shuo

model:

DYDT

Customized processing:

correct

For detailed product selection based on specific working conditions, please contact the company's technical department at 181 4977 8686


summary:

The DYDT-Z-7 intelligent shaft vibration transmitter combines the pre circuit of the eddy current sensor with the signal processing circuit,A precision measurement system for shaft vibration is formed by connecting eddy current sensor probes and extension wires,The product is highly integrated to achieve intelligence, with adjustable range according to customer needs, LED display, and alarm,And standard 4-20mA current output.Mainly monitoring the radial relative vibration of rotating machinery, monitoring due toThe increase in vibration caused by rotor imbalance, misalignment, and loose parts is widely used in power, metallurgy, and other fieldsVibration of large rotating machinery shafts (rotor relative to bearing cover) in industries such as petrochemicals, steel, and papermakingMeasurement and protection control.


Technical parameters:
1. Supply voltage: 24Vdc ± 10%
2. Power consumption:< 2W
3. Range: 0-800um (amplitude)
4. Signal input: DYHN800 series eddy current sensor probe
5. Display mode: Three and a half LED digital display
6. Output signal: 4-20mA (load ≤ 300 Ω)
7. Accuracy: Indication error 1%, standard output 1%
8. Frequency response: 0-10kHz
9. Buffer signal: 2-18V, output impedance 500 Ω (maximum 5mA)
10. Alarm output:
Output contacts: two groups (alert, danger)
Contact status: normally open (often closed when reaching the alarm value)
Electric shock capacity: 250VAC/3A or 30VDC/5A
Contact delay: 0s to 19s (optional)
11. Alarm status: self recovery, self-locking, bypass (optional)
12. Operating temperature:- 20℃~60℃
13. Storage temperature:- 30℃~ 85℃
14. Relative humidity: 20-95% without condensation

15External dimensions: 120mm (height) x 71mm (length) x 73mm (depth)