Implement standards and test methods that meet the requirements:
Neutral salt spray test can be conducted according to GB/T10125-2012, GB/T2423.17-2008, Kb salt test according to GB/T2423.18-2000, alternating (sodium chloride solution), (NSS), and acidic salt spray tests such as GB/T6460 and GB/T6459. Cyclic corrosion test can also be conducted according to CNS.4159 CASS accelerated copper acetate salt spray test, GB/T 12967.3 CASS accelerated copper acetate salt spray test, GB2423.3-2006, JLYY-JT46-08 and other standards.
Product features:
1. The test tank uses 12mm high-temperature and corrosion-resistant PP board products.
2. The upper cover of the test tank is made of 8mm high temperature and corrosion-resistant PP board products.
3. Machine shell: Made of 12mm high temperature and corrosion-resistant PP board, with a stainless steel frame in the middle to reinforce the overall firmness and load-bearing capacity of the testing machine, and foam insulation in the middle.
4. The box cover is equipped with a double-layer vacuum organic glass observation window for easy observation of the internal conditions of the box during the testing process.
5. Adopting high-precision imported temperature and humidity dedicated intelligent controllers to achieve effective control of temperature, humidity, and drying.
6. Imported fully enclosed high-power compressors from Europe and America.
7. Equipped with a device running time controller, it automatically shuts down after the running time accumulates.
8. Complete protection functions (such as water shortage, excessive humidity, overload, etc.) and equipped with sound, alarm, and shutdown functions.
Specification parameters
model
project
RK-FQY-90
RK-FQY-120
RK-FQY-160
Laboratory size mm
900* 600* 600
1200*850*700
1600* 900*700
Laboratory temperature
Neutral salt spray test at 35 ℃± 1 ℃/Acid salt spray test at 50 ℃± 1 ℃
Saturation bucket temperature
Neutral salt spray test 47 ℃± 1 ℃/Acid salt spray test 63 ℃± 1 ℃
Constant temperature test temperature and humidity
Temperature: 18 ℃~ 28 ℃± 0.5 ℃, humidity: ≥ 50% RH
Spray amount
1.0~2.0ml/h
Concentration of sodium chloride solution
5%
Laboratory volume
324L
612L
864L
power supply
380V50HZ
The laboratory can be customized according to customer requirements and the size of the studio